STEINEL LuxMaster BLS Скачать руководство пользователя страница 6

Functional Warranty

Declaration of conformity

This product complies with
Low Voltage Directive
06/95/EC, EMC Directive

04/108/EC and RoHS 
Directive 02/95/EC.

This Steinel product has been
manufactured with utmost
care, tested for proper opera-
tion and safety and then sub-
jected to random sample in-
spection. STEINEL undertakes
the guarantee for perfect con-
dition and function. 

The warranty period is 36
months and starts on the date
of sale to the consumer. We
will remedy defects caused by
material flaws or manufactur-
ing faults. The warranty will be
met by repair or replacement
of defective parts at our own
discretion. The warranty shall
not cover damage to wear
parts, damage or defects
caused by improper treatment
or maintenance. Further con-
sequential damage to other
objects is excluded.

Claims under the warranty
shall only be accepted if the
product is sent fully assem-
bled and well packed com-
plete with a brief description of
the fault, a receipt or invoice
(date of purchase and dealer's
stamp) to the appropriate Ser-
vice Centre.

Repair Service:
Our Customer Service Depart-
ment will repair faults not cov-
ered by warranty or after the
warranty period. Please send
the product well packed to
your nearest Service Centre.

21

Troubleshooting

Malfunction

Cause

Remedy

20

Light does not switch ON

No supply voltage

Lux value set too low

No motion detection

Check supply voltage

Slowly increase lux value
until light switches ON

Establish a clear view of
the sensor

Check detection zone

Light does not switch OFF

Lux value too high

Overshoot time running out

Interferring sources of
heat, e.g.: fan heaters,
open doors and windows,
pets

Reduce lux value

Wait until overshoot time
elapses; reduce overshoot
time if necessary

Blank off stationary
sources of interference 
using shrouds

Sensor switches OFF  
in spite of occupancy

Overshoot time too short

Increase overshoot time

Sensor switches OFF 
too late

Overshoot time too long

Reduce overshoot time

Sensor switches ON too
late when approached
frontally

Reach is reduced when 
approached frontally

Install further sensors

Reduce distance between
two sensors

Sensor switches
too frequently with chang-
ing cloud cover

Overshoot time set too
short

Increase overshoot time

more pleasant switching

behaviour

only BLS D, DF:

Sensor does not react to
changes in brightness in
test mode

Control leads (+,–) 
not correctly wired

Replace the control leads
on the sensor 

or

electronic

ballast

only BLS DF:

Sensor does not switch ON
with occupancy in spite of
darkness

Sensor previously switched
OFF with hand-held trans-
mitter

Lux value selected too low

Activate sensor by press-
ing the (+) button on the
hand-held transmitter

Increase lux value on the
sensor or by pressing the
(+ ) button on the hand-
held transmitter

The light level set with the
hand-held transmitter is no
longer saved

Settings deleted, since
voltage supply to the sen-
sor cut off
(e.g. by light switch or
power failure)

Ensure voltage supply to
the sensor

LuxMaster_10spr  27.08.2008  13:32 Uhr  Seite 22