STEINEL LuxMaster BLS Скачать руководство пользователя страница 5

Adjustment of the detection zone/reach

The shrouds supplied can be
used for deliberate adjustment
of the detection zone. Using
these, it is possible for exam-
ple to cleanly separate individ-

ual workplace areas in an
open-plan office so that only
movements in the area of the
respective desk group are de-
tected. We recommend acti-

vating test mode for rapid and
precise adjustment of the de-
tection zone (see page 16).

1

2
3

4

5

6
7
8

Vertical separation = 
reduction of the angle of coverage

Horizontal separation = 
reduction of the reach

The shrouds are divided into 8 areas (horizon-
tally). The reach is reduced depending on the

shrouds applied (number of areas).

(without cov.)

= 12 m

= 12 m

1

= 6.5 m

= 10 m

2

=

5 m

=

9 m

3

= 3.5 m

=

8 m

4

=

3 m

=

6 m

5

= 2.3 m

= 4.5 m

6

= 1.5 m

=

3 m

7

=

1 m

= 2.2 m

8

< 0.5 m

<

1 m

19

BLS DIMM

IR remote control

For the sensor BLS DF the op-
tion also exists of adjusting
the desired light level by
means of an infrared remote
control. The last selected set-
ting is respectively maintained
in this case. By constantly
pressing the (–)-button, the
lighting also be switched OFF
completely using the remote
control. By subsequent press-
ing the (+) button, the desired
level of brightness can be
readjusted.

Reset function

By simultaneously pressing
both buttons (+) and (–), all the
modifications made using the
remote control are reset to the
brightness setting adjusted on
the sensor.

Important note:

During adjustment of the
brightness setting, it should
be noted that the measured

brightness values of the sen-
sor refer to the installation site
of the sensor under the ceiling
and may therefore not neces-

sarily correspond to the 
desired brightness at the
workplace. 

Guideline values for adjusting the lux and time value

The following guideline values may be taken as a basis:

Brightness setting:

Passageways (not working areas):

200 lux

Working areas (offices, training rooms, workshops etc.):

500 lux

Working areas requiring good light:
(technical drawing, laboratories, precise work)

700 – 1000 lux

Switch-off delay:

The switch-off delay can be continuously adjusted according to the use of the respective rooms:

Mainly standing activities (e. g. photocopier room, passageways etc.):

4 min.

Mainly seated activities (desk work by 3–4 individuals):

7 min.

Mainly seated activities (desk work by 1–2 individuals):

10 min.

Seated activities with little movement (reading, EDP, etc.):

> 10 min.

If the lighting immediately switches ON again in response to movement in spite of occupancy, 
the switch-off delay is to be increased.

18

Functions

BLS DF

A
r

Shroud 
(see drawing)

Reach 
(installation 
at a height 
of 2.5 m)

Reach 
(installation 
at a height 
of 5 m)

AC
SE

LuxMaster_10spr  27.08.2008  13:32 Uhr  Seite 20