16
17
pose. Weather conditions
may affect the way the
motion detector works.
Strong gusts of wind, snow,
rain or hail may cause the
light to come ‘on’ when it is
not wanted because the
sensor is unable to distin-
guish sudden changes of
temperature from sources of
heat. The detector lens may
be cleaned with a damp cloth
if it gets dirty (do not use
cleaning agents).
Operation/Maintenance
The Infrared Sensor is
suitable for switching light
‘ON’ and ‘OFF’ automatically.
The unit is not suitable for
special burglary alarm
systems since it lacks
the tampering protection
prescribed for this pur-
Wiring examples
1. Light without neutral conductor
4. Connection to doublethrow switch
for permanent light ‘ON’ and automatic
operation
Setting I: automatic operation
Setting II: manual operation for permanent
light ‘ON’
Important: the unit cannot be switched off,
but operated only at settings I and II.
3. Connection using series switch for
manual and automatic operation
1)
e.g. 1-4 × 100 W filament bulbs
2)
Service load, light of 600 W max. (see Technical specifications)
3)
IS 2160 connection terminals
4)
Indoor switch
5)
Indoor series switch, manual, automatic
6)
Indoor double-throw switch, automatic, permanent light ‘ON’
Without power
Fuse blown, not switched
‘ON’
Short circuit
Renew fuse, switch ‘ON’
mains power switch,
check wiring with voltage
tester
Check connections
Does not switch ‘ON’
Twilight setting in
nighttime mode during
daytime operation
Bulb blown
Mains switch ‘OFF’
Fuse blown
Detection zone not
properly targeted
Readjust
Replace bulb
Switch ‘ON’
Renew fuse, check
connection if necessary
Re-adjust
Troubleshooting
Malfunction
Cause
Remedy
Dimensions:
(H × W × D) 113 × 78 × 73 mm
Output:
Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Fluorescent lamps, parallel-corrected
Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
Connection:
230 – 240 V, 50 Hz
terminal block suitable for following supply leads:
3-core Ø 1.5 or 2.5 mm
2
or 5-core Ø 1.5 mm
2
Angle of coverage:
160° with sneak-by guard
Pivoting range:
40° horizontal, 70° vertical
Reach:
12 m max.
Light threshold:
2 – 2000 lux
Time setting:
8 sec. – 35 min. (factory setting: 10 sec.)
Light threshold:
2 – 2000 lux (factory setting: 2000 lux)
Enclosure:
IP 54
Temperature range:
-20 °C to +50 °C
Technical specifications
600 W
430 W
500 VA
406 VA
406 VA
500 VA
16 W
64 W
64 W
88 µF