19
18
9� Disposal
Electrical and electronic equipment, acces-
sories and packaging must be recycled in an
environmentally compatible manner.
Do not dispose of electrical and
electronic equipment as domestic
waste.
For EU countries only: u
nder the current
European Directive on Waste Electrical and
Electronic Equipment and its transposition in
national law, electrical and electronic equip-
ment no longer suitable for use must be col-
lected separately and recycled in an environ-
mentally compatible manner.
10� Warranty
As purchaser, you are entitled to your statutory
rights against the vendor. If these rights exist
in your country, they are neither curtailed nor
restricted by our Warranty Declaration. We
guarantee that your STEINEL Professional sen-
sor product will remain in perfect condition and
proper working order for a period of 5 years.
We guarantee that this product is free from
material-, manufacturing- and design flaws.
In addition, we guarantee that all electronic
components and cables function in the proper
manner and that all materials used and their
surfaces are without defects.
Making Claims
If you wish to make a claim, please send your
product complete and carriage paid with the
original receipt of purchase, which must show
the date of purchase and product designation,
either to your retailer or contact us at
STEINEL
(UK) Limited, 25 Manasty Road, Axis Park,
Orton Southgate, Peterborough, PE2 6UP
,
for a returns number. For this reason, we
recommend that you keep your receipt of
purchase in a safe place until the warranty pe-
riod expires. STEINEL shall assume no liability
for the costs or risks involved in returning a
product.
For information on making claims under the
terms of the warranty, please go to
www�steinel-professional�de/garantie
If you have a warranty claim or would like to
ask any question regarding your product,
you are welcome to call us at any time on our
Service Hotline
01733 366700
.
GB
11� Technical Specifications
Dimensions (H × W × D)
120 × 117 × 120 mm
Mains voltage
120-250 V, 50 / 60 Hz
Output
Bulbs, 2000 W max. at 230 V *
1)
Fluorescent tube, 1000 VA max.
at 230 V (cos
j
= 0.5)
Starting current
max. 800 A / 200 μs
Electronic ballast *
2)
:
8 × 58 W max., C ≤ 176 μF,
Total capacity: 230 VAC
Angle of coverage
160°
Sensor system
5.8 GHz, 1 mW
Reach
1-5 m (approx. 7 m max.)
Time setting
30 s - 30 min, 10 s - 30 min (by remote control RC9)
Manual override
selectable (4h)
Twilight setting
2 - 2000 lux
Max. area covered
approx. 68 m²
IP rating
IP 54
Temperature range
-20° to +50°C
*1)
VDE-tested
*2)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast (total capacity of all ballasts connected below
the level stated).
MANUFACTURER'S
1
3
5
Y E A R
G B
WARRANTY
MANUFACTURER'S
Y E A R
WARRANTY
MANUFACTURER'S
Y E A R
WARRANTY
Malfunction
Cause
Remedy
No power at the sensor
n
Fuse has tripped,
not switched ON,
break in wiring
n
Short circuit
n
Activate, change fuse,
turn ON power switch, check
wiring with voltage tester
n
Check connections
Sensor will not switch ON
n
Twilight setting in night mode
during daytime operation
n
Bulb faulty
n
Mains power switch OFF
n
Fuse has tripped
n
Detection zone not properly
targeted
n
Adjust setting
n
Change bulb
n
Switch ON
n
Activate, change fuse, check
connection if necessary
n
Readjust
Sensor will not switch OFF
n
Continuous movement in
the detection zone
n
Check zone, adjust or fit
shrouds if necessary
n
Change zone, or fit shrouds
n
Deactivate 4 h manual
override
Sensor keeps switching ON/OFF
n
Light being operated is
located in detection zone
n
Change zone or fit shrouds,
increase distance
12� Troubleshooting
Содержание iHF 3D
Страница 3: ...4 5 A B C D E F G 3 4 4 1 4 2 4 3 5 1 5 2...
Страница 4: ...6 7 5 6 6 1 5 4 5 5 5 3...
Страница 5: ...8 9 6 4 6 2 6 3 4h ON INSTALL 6 5 1 2 5 6 7 8 4 9 3 7 1...