background image

16

17

turning the unit ON and OFF may of course be 

installed in the mains supply lead. 

 

5�  Mounting

•  Check all components for damage.

•  Do not use the product if it is damaged.

Mounting procedure

•  Select appropriate site of installation, giving 

consideration to sensor reach and detection 

of movements 

(Fig� 3�3)

•  Switch OFF power supply 

(Fig� 4�1)

•  Mark drill holes 

(Fig� 5�1)

•  Drill holes and insert wall plugs 

(Fig� 5�2)

–  Concealed power supply lead 

(Fig� 5�2)

–  Surface-mounted power supply lead 

(Fig� 5�3)

•  Connect conductors 

(Fig� 4�2)

•  Make plug connection 

(B)

 

(Fig� 5�4)

•  Screw sensor unit 

(C)

 into place 

(Fig� 5�5)

•  Switch ON power supply 

(Fig� 5�6)

•  Make settings 

 "

6� Operation" 

 

6�  Operation

Operation/function legend 

(Fig� 6�1)

Note: 

After connecting to the mains power 

supply, the white Status-LED flashes for 10 s. 

The sensor is then ready for operation. 

 

Factory settings

Time setting: Install (pos. 8)

Reach setting: 3x MAX

Light-level setting 1000 lux (pos. 7)

Functions

Time setting (Fig� 6�2 / H)

The time you wish the connected load to stay 

ON for can be adjusted to any of six settings: 

30 seconds, 1 minute, 2 minutes, 5 minutes, 

15 minutes to 30 minutes.

Pulse mode (Fig� 6�2 / H) 

If you set the control dial to 

 

(pos� 1)

the unit is in pulse mode, i.e. the output is 

switched ON for approx. 2 sec. (e.g. for 

staircase lighting timer). Afterwards, the sensor 

does not react to movement for approx. 8 s.

Install mode (Fig� 6�2 / H) 

Install mode has the purpose of checking for 

proper working order as well for testing the de-

tection zone. Irrespective of light level, the light 

connected switches ON for 10 s in response to 

movement (Status-LED flashes). Install mode 

has priority over all other settings. Change 

control dial setting to quit Install mode. When 

making settings with the RC9 remote control, 

Install mode ends automatically after 10 min.

Reach setting (Fig� 6�2 / I 1-3)

Reach can be infinitely adjusted in three direc-

tions via three control dials from 1-5 m (max. 

approx. 7 m) independently of each other. The 

maximum detection reach is selected via the 

control dials. 

Detection diagram 

(Fig� 6�3)

 

Note:

 if the distance to a wall or similar struc-

ture is less than 7 m in any of these directions, 

the reach in that direction must still be set to 

maximum reach or detection errors may be 

made. The reach settings should only be used 

to mask out areas in which you do not want 

movement to result in light being switched ON. 

Performance of the iHF 3D may also be 

impaired by installing it in corners or on metal 

building exteriors.

Light-level setting

(Response threshold) (Fig� 6�2 / J)

The sensor’s chosen response threshold can 

be infinitely varied from approximately 2 to 

1000 lux.

Teach mode

Teach mode 

(Fig� 6�2 / J / pos� 8)

 saves the 

current ambient light level below which you do 

not want the sensor to respond to movement 

from now on.

Manual override function (Fig� 6�4 / 6�5)

If a mains switch is installed in the mains  

supply lead, the following functions are 

provided in addition to simply switching light 

ON and OFF:

Sensor mode: (Fig� 6�4)

 

– Switch light ON (when light is OFF):

 

– Switch OFF and ON once. Light stays ON for 

the period selected.

 

– Switch light OFF (when light is ON):

 

– Switch OFF and ON once. Light goes out or 

switches to sensor mode.

Manual override (Fig� 6�5)

 

Activate manual override:

 

– Turn switch OFF and ON twice. The light 

is set to manual override for 4 hours (Sta-

tus-LED ON). Then it returns automatically to 

sensor mode (Status-LED OFF).

 

Deactivate manual override: 

 

– Switch OFF and ON once. Light goes out or 

switches to sensor mode.

Important: 

The switch must be actuated in 

rapid succession (in the 0.2 - 1 s range). 

 

7�  Accessories 

Remote control RC9 

(EAN 4007841007638)

Any number of iHF 3D sensors can be 

controlled by the RC9 remote control. The 

Status-LED on the sensor flashes (once) to 

indicate each valid press of the button. The 

Status-LED flashes (twice) to indicate each 

valid press of the button. 

(Fig� 7�1)

Functions:

Light-level setting

The chosen response threshold can 

be set from approx. 2-1000 lux.

Daylight operation

Night-time operation

Teach mode

  

This button must be pressed at the 

level of light at which you want the 

sensor to respond to movement 

from now on.  

The current value is stored.

Time setting

The period of time you want the 

light to stay ON for after the last  

detected movement can be set 

to 10 s, 1 min, 5 min, 15 min by 

pressing these buttons.

Light ON time

Setting the light to stay ON for a 

time of your own choice. Each 

press of the button increments  

the current time setting by 1 min  

(up to 30 min).

Manual override function

Pressing this button switches the 

light ON for 4 hours (Status-LED 

on). The light then returns to sensor 

mode automatically. Pressing the 

button for a second time (before the 

4 h period expires) returns the light 

to sensor mode.

Install mode

Install mode has the purpose of 

checking for proper working order 

as well for testing the detection 

zone. Irrespective of light level, the 

light switches ON for 10 s in re-

sponse to movement. (Status-LED 

flashes).

Install mode has priority over all 

other settings. Install mode ends 

automatically after 10 min. Install 

mode ends immediately after 

pressing reset.

Note:

 Teach mode and Install  

mode cannot be used at one  

at the same time.

Reset

 

Resets all settings to the values 

selected on the light manually or  

to the factory settings.

Smart Remote (optional)

(EAN 4007841009151)

 

– Control by smartphone or tablet

 

– Replaces remote control

 

– Load appropriate app and connect via 

Bluetooth

8�  EC Declaration of Conformity

STEINEL Vertrieb GmbH hereby declares that

the iHF 3D conforms to Directive 2014/53/

EU. The full wording of the EU Declaration of 

Conformity is available for downloading from 

the following Internet address:  

http://www.steinel.de http://www.steinel.de

5

6

7

GB

 

 

1

2

3

4

8

9

Отзывы: