6
MALFUNCTION
POSSIBLE CAUSE
ELIMINATION
2. The motor is running, but
the pump is not
discharging any liquid.
1. The intake openings are clogged.
2. The pressure line is clogged.
3. Air penetrates into the pump body.
4. The min. suction level was fallen short of;
possibly incorrect setting of the floating
switch, motion of floating switch restricted,
floating switch defective.
5. Check valve (non-return valve), if present, is
blocked or defective.
1. Remove possible congestion.
2. Remove possible congestion.
3. Start pump several times so that the entire
air will be driven out.
4. Make sure that the minimum suction level is
not fallen short of; if necessary, adjust
floating switch properly or make sure that it
can move freely; in the case of a defective
floating switch, please contact customer
service.
5. Eliminate blocking of the check valve (non-
return valve) or replace, if damaged.
3. The pump stops after a
short time of operation
because the thermal motor
protection feature has
triggered.
1. The electrical supply does not correspond to
the information given on the type plate.
2. Pump or intake openings are blocked by
solids.
3. Liquid is too viscous.
4. Temperature of the liquid is too high.
5. Pump is running dry.
1. Please use a device complying with GS
(German technical supervisory authority) to
check the voltage of the lines of the
connection cord (safety information to be
observed!).
2. Remove possible congestion.
3. Pump may not be suitable for this liquid. If
feasible, the liquid should be thinned.
4. Make sure that the temperature of the liquid
being pumped does not exceed the max.
admissible value.
5. Eliminate causes of dry-running.
4. Intermittent or irregular
operation.
1. Pump wheel obstructed by solid matters.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Mains voltage out of tolerance.
5. Motor or pump wheel defective.
1. Remove solids.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Make sure that mains voltage matches that
indicated on the type plate.
5. Please contact the customer service
department.
5. Water quantity discharged
by pump is inadequate.
1. Refer to section 2.1.
2. Refer to section 2.2.
3. Worn pump wheel.
1. Refer to section 2.1.
2. Refer to section 2.2.
3. Please contact the customer service
department.
6. The pump does not cut in
or out.
1. Floating switch cannot move freely.
2. Incorrect setting of floating switch.
3. Floating switch defective.
1. See that floating switch can move freely.
2. Correct floating switch settings.
3. Please contact the customer service
department.
9. Warranty
The present device was manufactured and inspected according to the latest methods. The seller warrants for
faultless material and workmanship in accordance with the legal regulations of the country in which the device
was purchased. The warranty period begins with the day of the purchase and is subject to the provisions below:
Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will
be eliminated free of charge. Any complaints are to be reported immediately upon their detection.
The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties.
Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection
or installation or Acts of God or other external influences are excluded from warranty.
Parts being subject to wear and tear, such as the pump wheel (impeller) and mechanical shaft seals are excluded
from warranty.
All parts were manufactured using maximum care and high-quality materials and are designed for a long lifecycle.
It should be understood, however, that the wear and tear depends on the kind of use, the intensity of use and the
internals of maintenance. Complying with the installation and maintenance information contained in the present
operating instructions will therefore considerably contribute to a long lifecycle of these wearing parts.
In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire
device. Replaced parts will pass into our property.
Claims for liquidated damages are excluded unless they are caused by wilful acts or negligence on the side of the
manufacturer.
The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be
evidenced by the purchaser in the form of the submission of the sales receipt. The present warranty commitment
is valid in the country in which the device was purchased.
41
Содержание S-MAX 550 S
Страница 24: ...1 STEINBERG 1 1 2 2 3 2 4 3 5 3 6 4 7 4 8 5 9 7 10 7 11 7 1 RCD FI 30 mA 22...
Страница 26: ...3 4 5 5 1 1 2 3 5 2 1 11 33 25 1 47 80 1 25 34 a b 47 80 1 5 3 5 4 24...
Страница 27: ...4 2 3 4 5 5 5 6 6 Fl 30 mA DIN VDE 0100 739 3 x 1 0 mm VDE 7 25...
Страница 28: ...5 230 V STEINBERG 8 8 26...
Страница 30: ...7 9 vis major a 1 2 3 10 www tip pumpen de 11 PDF service tip pumpen de EU EU 2012 19 EU 28...
Страница 45: ...Za cznik rysunki Mell klet br k Dodatak Slike Anexe Desene Annex Illustrations S MAX 550 S S MAX 850 S...