background image

Page 10

(;73DUWV/LVW&RQWLQXHG«

DWG.

REF.

NO.

DESCRIPTION

212EXT

ITEM NO.

312EXT

ITEM NO.

412EXT

ITEM NO.

512EXT

ITEM NO.

612EXT

ITEM NO.

43.

Block Insulation, Right (Std Output)

1052040

1052040

1052040

1052040

1052040

"

Block Insulation, Left (Std Output)

1052022

1052022

1052022

1052022

1052022

46.

Grill

5942080

5942081

5942082

5942083

5942084

47.

*Fan Assembly w/o Fan (Std Output)

1040092

1040093

1040094

1040095

1040109

48.

*Fan Wiring Harness (Std Output)

1040290

1040291

1040292

1040293

1040294

49.

Charge Control Sequencer

N/A

N/A

1040000

1040000

1040000

50.

*Red Service Light (240VAC)

1015021

1015021

1015021

1015021

1015021

51.

Painted Panel, Right

5942040

5942040

5942040

5942040

5942040

52.

Painted Panel, Left

5941140

5941140

5941140

5941140

5941140

53.

*Fan with Motor & Shroud (230 VAC)

1022000

1022007

1022004

1022004

1022007

54.

*Heating Element (1200W, 240 VAC)

1040079

1040079

1040079

1040079

1040079

55.

Sequencer Mounting Bracket

N/A

N/A

5941082

5941082

5941082

56.

Fan High Limit Switch

1012013

1012013

1012013

1012013

1012013

57.

T-Block Mounting Bracket, Center

N/A

N/A

N/A

5941083

N/A

58.

Wall Bracket Hardware Kit

1190002

1190002

1190002

1190002

1190002

59.

Green Charge Light, Optional

1015026

1015026

1015026

1015026

1015026

60.

Right Panel,  Front

5942047

5942047

5942047

5942047

5942047

61.

Charge Control Assy (130o)

1040282

1040282

1040282

1040282

1040282

62.

Charge Control Assy (265o)

1040305

1040305

1040305

1040305

1040305

63.

Charge Control Assy (190o)

1040284

1040284

1040284

1040284

1040284

64.

Cord Assembly (120 VAC)

1015000

N/A

N/A

N/A

N/A

65.

Room Temp. Control Knob

1154006

1154006

1154006

1154006

1154006

66.

Tip Over Switch (120V plug-in units)

1024018

N/A

N/A

N/A

N/A

67.

Outdoor Temperature Sensor, optional

1040300

1040300

1040300

1040300

1040300

68.

Circuit Board Mounting Plate

5942087

5942087

5942087

5942087

5942087

69.

*Circuit Board Face Plate

*

*

*

*

*

70.

Low Voltage Wire Channel

5942090

5942090

5942090

5942090

5942090

71.

Outdoor Sensor Interface Board, optional

1043020

1043020

1043020

1043020

1043020

72.

Security Base Shell (120V plug-in units)

5942110

N/A

N/A

N/A

N/A

73.

Security Base Filler (120V plug-in units)

1190020

N/A

N/A

N/A

N/A

74.

*Time Clock (240 VAC), optional

1301006

1301006

1301006

1301006

1301006

75.

Peak Control Sequencer, optional

1309006

1309006

1309006

1309006

1309006

76.

Utility Mode Timer, optional

1018015

1018015

1018015

1018015

1018015

77.

Peak Override Wind-up Timer, optional

1024020

1024020

1024020

1024020

1024020

78.

Multi-Mode Interface Board, optional

1023030

1023030

1023030

1023030

1023030

*

Contact factory with model and serial number as optional voltages, wattages, high output fan assemblies and circuit

board configurations are available.

Содержание 212EXT

Страница 1: ...9 7528 6 227 1 8 25 5220 7 1 81 76 02 6 7 7 7 7 7...

Страница 2: ...RUV RU PLVFDOFXODWLRQV FRQWDLQHG KHUHLQ RU DQ UHYLVLRQV KHUHRI RU ZKLFK UHVXOW ZKROH RU LQ SDUW IURP WKH XVH RI WKLV JXLGH RU DQ UHYLVLRQ KHUHRI I WKHUH DUH DQ TXHVWLRQV FRQWDFW 6WHIIHV RUSRUDWLRQ 7HF...

Страница 3: ...unit wiring Place the charge level switch in the Med position Does the charging light turn on Remove the jumper between the yellow and gray wire Does the charging light turn off Place the charge level...

Страница 4: ...ded components refer to the Exploded View Diagram UNIT CHARGES UNEVENLY Check unit amperage Check fans 53 and dampers for smooth operation Check heating elements 54 charge control sequencer 49 and cor...

Страница 5: ...er to the Exploded View Diagram Check room thermostat 23 for possible miscalibration Check voltage across F2 F3 terminal block positions 24 Fan s Do Not Operate Fan s Operate Voltage Present Remove th...

Страница 6: ...ostat and circuit breaker settings NOTE For cross reference to number coded components refer to the Exploded View Diagram DISCHARGE AIR TOO WARM Check for damper jamming or obstruction Check bimetalli...

Страница 7: ...the Exploded View Diagram NOTE To test the bimetallic coil assembly it must be completely cold Either allow room unit to cool completely or remove fan assembly and cool to room temperature Once the co...

Страница 8: ...board 29 Fix unit wiring Incorrect Yes Fix or replace peak control device time clock etc Fix field wiring Incorrect Correct No Correct MODEL EXT FUNCTION Peak Control PROBLEM Green Off Peak light does...

Страница 9: ...Page 8 EXPLODED VIEW DIAGRAM...

Страница 10: ...Std Output 5941116 5941118 5941120 5941122 5941124 20 Painted Panel Bottom 5942030 5942031 5942032 5942033 5942034 21 Brick Support Assembly Std Output 5941106 5941108 5941110 5941112 5941114 22 Grill...

Страница 11: ...Front 5942047 5942047 5942047 5942047 5942047 61 Charge Control Assy 130o 1040282 1040282 1040282 1040282 1040282 62 Charge Control Assy 265o 1040305 1040305 1040305 1040305 1040305 63 Charge Control...