background image

2  |  Espire Elbow Classic Plus, Classic and Basic -  

User Guide

User Guide -

 Espire Elbow Classic Plus, Classic and Basic  |  3

WELCOME

Intended Use

The Espire Elbow system is to be purchased, configured and fitted by a 

qualified prosthetist.

The operations contained in this document are intended for the end user.

Intended Use Statement

The Espire Elbow is to be used exclusively for external prosthetic fittings of 

the upper limbs. 

What’s Included with Your Device

Espire Elbow System

Welcome to the Espire Elbow system from Steeper Group. The following 

pages will cover everything you need to know about the elbow operation. 

If you have any questions, concerns or comments, please contact your 

prosthetist.

This User Guide covers instructions for 3 types of elbow models:

Espire Classic Plus 

– Mechanical elbow with manual lock and forearm 

counterbalance for lift compensation. Body-powered elbow operation. 

Includes wired connection points at the proximal and distal ends of the elbow 

for easy connections to input and output devices.

Espire Classic 

– Mechanical elbow with manual lock and forearm 

counterbalance for lift compensation. Body-powered only.

Espire Basic –

 Mechanical elbow with manual lock and forearm spring-assist 

for lift compensation. Body-powered only.

Features

Classic Plus

Classic

Basic

Elbow Joint 

Control

Mechanical

Mechanical

Mechanical

Terminal Device 

Control

Electronic/ 

Mechanical

Mechanical

Mechanical

Elbow Lock

Mechanical

Mechanical

Mechanical

Lift Compensation

Counterbalance

Counterbalance

Spring-Assist

Technical Specifications

Specifications

Weight Limit

25lb/11.3kg

Flexion Angle (preset control)

-5° - 135°

Environmental Use Conditions

Operating (temperature)

5°C to 40°C (41°F to 104°F) 

Storage & Transport (temperature)

-20°C to +60°C (-4°F to 140°F)*

Operating Relative Humidity

15% to 90%

*Note: If storing device above or below operating temperature, allow 

the device to return to within operating temperature range and leave 

the device to sit for 15 minutes before using.

IP Rating

Protected from touch by fingers and objects greater than 12 

millimetres. Protected from water spray less than 15° from vertical.

BATTERY

(Classic Plus Only) 

The Espire Classic Plus has a built-in battery compartment which could be 

used to house a battery. The charging port and switch may be located near 

this compartment. Your prosthetist can instruct you on how to use it properly.

Содержание Espire Classic Plus

Страница 1: ...Espire Elbow Classic Plus Classic and Basic User Guide ...

Страница 2: ...rm counterbalance for lift compensation Body powered only Espire Basic Mechanical elbow with manual lock and forearm spring assist for lift compensation Body powered only Features Classic Plus Classic Basic Elbow Joint Control Mechanical Mechanical Mechanical Terminal Device Control Electronic Mechanical Mechanical Mechanical Elbow Lock Mechanical Mechanical Mechanical Lift Compensation Counterbal...

Страница 3: ...k to disengage THE COUNTERBALANCE SPRING ASSIST Counterbalance and Spring assist Overview Depending on which model you are using the Espire will include either a counterbalance or spring assist mechanism Espire Model Lift Compensation Aid Classic Plus Classic Counterbalance Basic Spring assist Both the counterbalance and spring assist aid in flexion and extension of the Espire Elbow Different amou...

Страница 4: ...this device around pets that may cause damage to the device INTENDED USE AND SAFETY Intended Use Statement The Espire Elbow is to be used exclusively for external prosthetic fittings of the upper limbs Intended Users The Espire Elbow is intended for use only by the individual being fit with the device The manufacturer does not approve use by any other person s The Espire Elbow system is to be purc...

Страница 5: ...veryday use and must not be used for unusual activities These unusual activities include for example sports with excessive strain and or shocks to the wrist joint pushups downhill mountain biking etc or extreme sports free climbing paragliding etc Do not use when swimming or in wet environments Careful handling of the prosthesis and its components not only increases their service life but above al...

Страница 6: ...low specific disposal or recycling instructions for this product Residents outside the European Union must dispose or recycle this product in accordance with local laws or regulations that apply IS EN 50419 2006 Reference no Fig 1 Caution Federal USA law restricts this device to sale by or on the order of a physician USA Code of Federal Regulations 21 CFR Part 801 801 109 b 1 Refer to instruction ...

Страница 7: ...zzo Drive Leeds UK LS10 1DF Steeper Group Unit 3 Stourton Link Intermezzo Drive Leeds LS10 1DF Tel 44 0 870 240 4133 Email customerservices steepergroup com SteeperUSA 8666 Huebner Road Suite 112 San Antonio TX 78240 Tel 1 210 481 4126 Email inquiries steeperusa com STPPR147 Issue 1 November 2020 ...

Отзывы: