background image

Page 12 of 12

939599284 Rev D

®

125cm

to floor

Maximum 45cm

to extrusion

ALCOHOL 

PREP PAD

1

2

3

5

6

STANDARD GLASS MOUNT

#2

4

Содержание RoomWizard II

Страница 1: ... Mexico Puerto Rico and the U S Virgin Islands call 1 616 247 2500 Or visit our website www steelcase com 2011 Steelcase Inc Grand Rapids MI 49501 U S A Printed in U S A 2 PHILLIPS BIT Topic Page Rail Mount Kit 2 Privacy Wall Mount Kit 5 Post and Beam Mount Kit 7 media scape Mount Kit 8 Single Gang Junction Box Mount Kit VIA Glass Mount Standard Glass Mount 9 10 12 Table of Contents RoomWizard II ...

Страница 2: ...ert two 2 screws through holes in adaptor plate and into T nuts Loosely tighten 3 Place adaptor plate onto extrusion making sure T nuts fit into slots 3a and mark hole with pencil 3b Remove adaptor plate and drill a 1 2 hole into extrusion FrameOne or c scape beam for power over ethernet cable 3c 4 Place adaptor plate back onto extrusion making sure T nuts fit into slots and tighten onto extrusion...

Страница 3: ...r plate using two 2 10 24 machine screws and two 2 washers 7 Align universal bracket cover and puck with the universal bracket mount Route power over ethernet cable through universal bracket cover and puck 7a Attach universal bracket cover and puck to universal bracket mount using the four 4 provided 6 32 machine screws with a 2 phillips screwdriver 7b 8 Refer to RoomWizard II installation quickst...

Страница 4: ...l bracket mount and loosely tighten 3 Place universal mount bracket onto rail making sure T nuts are placed into slot on rail 4 Route power over ethernet cable through square hole in bottom of universal bracket mount 5 Tighten the two 2 provided T nuts using a phillips screwdriver 6 Perform steps 6a and 6b on page 3 7 Refer to RoomWizard II installation quickstart guide for remaining assembly ...

Страница 5: ...not enough room for toggle anchor 1 Position universal mount bracket onto extrusion 1a Mark two 5 16 holes on extrusion for bracket hardware and one 1 1 2 hole for power over ethernet cable 1b Remove universal bracket mount from extrusion and drill two 2 5 16 holes for bracket hardware and one 1 1 2 hole for the power over ethernet cable 1c 2 Route cable through 1 2 drilled hole in extrusion ...

Страница 6: ... in bottom of universal bracket mount 4 Attach universal bracket mount to extrusion by inserting two 2 10 24 screws with washers through holes in universal bracket mount holes in extrusion and holes in mounting bracket 5 Level RoomWizard II and adjust screws if necessary 6 Align universal bracket and puck with the universal bracket mount Route power over ethernet cable through universal bracket co...

Страница 7: ...oute power over ethernet cable through square hole in bottom of universal bracket mount 4 Tighten the two 2 provided T nuts using a phillips screwdriver 5 Perform steps 5 6a and 6b on page 6 6 Refer to RoomWizard II installation quickstart guide for remaining assembly NOTE Do not mount RoomWizard II s so they protrude into an aisleway ADA requires objects projecting from walls with their leading e...

Страница 8: ...l for fasteners 1a and one 1 location to drill for cable 2 Confirm there are no items that could pose an interference on the rearside of the media scape shroud 3 Drill 1 2 dia hole for power over ethernet cable and 1 4 dia holes for fasteners 4 Route power over ethernet cable through drilled 1 2 dia hole in media scape shroud 5 Screw the puck onto the shroud using the provided four 4 screws and fo...

Страница 9: ...plate directly to junction box If box is vertical mount so the puck mounting holes are toward the top of the mount If the box is horizontal mount so the puck mounting holes are nearest the room opening 3 Attach RoomWizard II to puck using two 2 provided set screws with a 2 phillips screwdriver 4 Level RoomWizard II Adjust screws if necessary 5 Refer to RoomWizard II installation quickstart guide f...

Страница 10: ...lass frame C and remove 2 Clean mounting area of exterior glass frame A with alcohol pad on both sides 54 1 4 up from floor 8 in from side 3 Maintain cable length at 8 across face of glass frame INSTALLATION OF VIA INTERIOR SIDE GLASS FRAME C 8 51 1 4 FRAME A SIDE GLASS ...

Страница 11: ...face with an alcohol pad 6 Remove film backing from adhesive pad Locate alignment tabs against edge of glass frame and press VIA mount onto glass VIA Mount will be centered at 51 1 4 H 7 Position tab of wall bracket at top and fasten bracket to mount with 4 fasteners 8 Remove film backing and affix back cover plate to opposite of glass Refer to Room Wizard II Installation Quick Start Guide for rem...

Страница 12: ...Page 12 of 12 939599284 Rev D 125cm to floor Maximum 45cm to extrusion ALCOHOL PREP PAD 1 2 3 5 6 STANDARD GLASS MOUNT 2 4 ...