5 Errors and faults
5.2.1 Table of error messages with the Up/Down
control panel
Signal/Code
Message
Required measure(s)
Lamp not lit
Normal system
operation
The DM system can be used
as usual
The system is not
correctly connected
Instructions on how to
correctly connect the system
can be found in the DM
system manual
Flashing red
Warning - System
error
Release all buttons and wait
5 seconds. Then try to
repeat the action.
Disconnect the DM system
from the power supply.
(If a power lift is used)
disconnect the power lift
from the mains. Check the
power supply system for
overheating. Let it cool if
required. Check all cable
connections and re-connect
the system.
Should the problem persist:
■ Perform a "manual reset".
■ Contact LOGICDATA.
Flashing green
System starts up
To carry out any subsequent
steps, wait until the LED is
no longer flashing. Do not
press any buttons!
The system is being
reset
Duty cycle exceeded
Collision detected
(ISP)
Remove the obstacle from
the table system. Remove
any unnecessary loads from
the desktop. The DM system
can be used as usual .
26