Assembly Directions
93-9501116 REV A
Page
2 of 4
1.
Acoustical Panels Installed On Backs Of Series 9000
®
Units
Refer to chart and below figure for center punch
locations. Punch required locations for your size
acoustical panel. Drill 7/64” Dia. pilot holes.
2.
Position and secure (2) top brackets
with (1) screw.
3.
Position and secure (2) bottom brackets
with (1) screw.
4.
Place acoustical frame return flange onto (2) top
brackets. Push bottom of acoustical panel in
until the bottom brackets snap into place.
NOTE: To remove the acoustical panels, lift up
and tilt from side to side.
SCREW
NO. 6 TEK
BOTTOM
BRACKET
TOP
BRACKET
ACOUSTICAL FRAME
RETURN FLANGE
UNIT SIZE PANELS REQ’D DIM. “A” DIM. “B” DIM. “C”
65” x 75” 2 6-1/2” 27-7/8” 10”
65” x 70”
2
6-1/2” 25-3/8” 10”
65” x 65”
2
6-1/2” 22-7/8” 10”
65” x 60”
2
6-1/2” 20-3/8” 10”
65” x 45”
1
6-1/2” --- 10”
MOUNTING CLIP HOLE LOCATIONS
5/8”
10”
A
B
C
TOP
BRACKET
SCREW
NO. 6 TEK