Installation

11

Electrical connections

The connections must be performed in 
compliance with the legal standards in force.
Check that the relief valve and the electrical 
system are able to support the load of the 
appliance.
The equipment is not fitted with plugs.
The yellow/green earth wire must not be 
disconnected by the switch.
The technical specifications of the appliance are 
shown on the rating plate located inside the range 
hood. Make sure the mains voltage corresponds 
to the values on the rating plate.

Use plugs conforming to current electrical standards, 
taking into account that:
• the yellow-green wire must be used for the earth;
• the blue wire must be used for the neutral;
• the brown wire must be used for the phase; the cable 

must not come into contact with hot parts (over 75°C);

• fit a plug that is suitable for the load to the power cable, 

and connect it to a suitable power outlet.

Before plugging in the appliance, check that:
• the power voltage corresponds to that indicated on the 

specification plate;

• the earth connection is correct and operational;
• the power supply system has an effective earth 

connection according to current legislation;

• the socket or the omnipolar switch used are within easy 

reach when the appliance is installed.

Test

Check:
• that the duct and external outlet are not blocked;
• the metallic and active charcoal filters (if fitted) are 

positioned correctly. Refer to section “Active charcoal 
filters” on p. 16.

Connect the hood to the electric supply, switch on the 
motor as described in section “Operation” on p. 12 and 
check:
• the correct operation and suction capacity at all 

selectable speeds;

• the correct operation of the lights.

Содержание Genesi GK120

Страница 1: ...INSTRUCTION MANUAL Exhaust recirculating hood GB...

Страница 2: ......

Страница 3: ...ff button 12 Increase button 12 Decrease button 12 Intensive operation 12 Timed switch off and filter saturation alarm 12 Light button 12 TIPS 13 Exhaust hood with outside discharge 13 Recirculating r...

Страница 4: ...aintenance repairs and checks to be carried out only when required and with the assistance of a qualified technician Accessories Description installation and use of the accessories supplied with the e...

Страница 5: ...NDARDS IN FORCE IF THE SUPPLY CORD IS DAMAGED IT MUST BE REPLACED BY THE MANUFACTURER ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSONS IN ORDER TO AVOID A HAZARD ANY MODIFICATIONS THAT MAY BE REQUIRED...

Страница 6: ...THE SYMBOL INDICATES THAT THIS APPLIANCE MAY NOT BE TREATED AS HOUSEHOLD WASTE INSTEAD IT SHALL BE HANDED OVER TO THE APPLICABLE COLLECTION POINT FOR THE RECYCLING OF ELECTRICAL AND ELECTRONIC EQUIPM...

Страница 7: ...tension one or two wall mounting bars depending on hood type two or four 8 mm toggle bolts with screws depending on hood type four 6 mm toggle bolts with screws ten self tapping screws plastic reducer...

Страница 8: ...6 Installation Dimensions 200 550 1100 300 600 300 600 400 500 200 400 500 700 900 1000 1172 580 350 350 260 260 250 300 550 500 700 900 1000 1200 700 900 1000 1200 Type K Type GK Type AK...

Страница 9: ...ount At horizontal sections the pipe must be slightly tilted upwards about 10 to allow the extracted air to exit more easily Keep the number of bends to a minimum and check that pipes are the minimum...

Страница 10: ...e suction motor fig 2 Removing the metallic filters Lower the splines A1 and pull the filters A downwards Keeping the filters tilted down remove them by pulling out The connector B is now accessible I...

Страница 11: ...the bar Drill the holes insert 2 x 8 mm dia screw anchors and fasten the bar using the corresponding screws Hook the range hood to the support bar Adjust the alignment of the range hood using the scr...

Страница 12: ...ed holes Use a spirit level to check the horizontal alignment and drill the holes Insert two 6 mm toggle bolts and fasten the mounting bar L to the wall Screw the telescopic component H to the mountin...

Страница 13: ...the cable must not come into contact with hot parts over 75 C fit a plug that is suitable for the load to the power cable and connect it to a suitable power outlet Before plugging in the appliance ch...

Страница 14: ...nters intensive operation mode the button flashes Intensive operation is timed and the motor returns automatically to the 3rd speed after about 15 minutes Timed switch off and filter saturation alarm...

Страница 15: ...hood with filter In this version the air passes through charcoal filters available on demand for purification and is then recirculated back into the kitchen Check that the charcoal filters are fitted...

Страница 16: ...hs according to use To replace the charcoal filters see the instructions Active charcoal filters on page 16 Metal grease trapping filters These trap the fat and grease particles suspended in the air a...

Страница 17: ...screwdriver the support ring A for the cover glass Remove the cover glass B to access the light compartment Replace the lamp with the same type halogen max 20 W 12 Volt G4 fitting Replace the glass co...

Страница 18: ...charcoal filters Two types of active charcoal filters are available depending on the hood model Models with square filter type K hoods Remove the metallic filters Place the nut F above the filter hou...

Страница 19: ...h on when the lights button is pressed Bulbs blown Replace them Bulbs not fully inserted Transformer faulty Contact Customer Service The motor starts but cooking fumes are not extracted Metallic or ac...

Страница 20: ...B00090 ZS5077 08 14...

Отзывы: