background image

ASSEMBLY SECTION

6

37 - 41 mm

1

TIGHTEN THE BELT/CHAIN

Note: The spring must be able to compress and bounce

during operation. Final tensioning can be performed after

installation if necessary. Over tightening the belt/chain may

overload the system and cause excessive wear.

1.On chain rails remove the transport lock (X) and ensure the

chain is seated on the gear wheel.

2.Tension the belt/chain by adjusting the nut (1), on the pulley

assembly, clockwise until the spring is engaged.

3.Continue tightening to compress the spring and remove all the

slack in the belt/chain. DO NOT OVERTIGHTEN but ensure

belt/chain is firm.

4.As indicated in the diagram 37-41 mm is normal.

A

1

1

3

4

5

2

1.Slide the RAIL BRACKET (1) onto the powerhead end of the

rail (A) around 200 mm.

2.Position the rail drive spocket (2) over the opener motor shaft

(3) and push down to install.

3.Secure the rail on the opener with two rail brackets (4) and

the hex head fixing 6 mm x 18 mm screws (5).

This completes the assembly of the powerhead to the rail.

FASTEN RAIL TO OPENER

9

10

The segmented rail is largely preassembled and consists of 3 parts. The carriage, push rod, release handle, the guide pulley

and the lintel bracket with belt/chain tensioner are in the front part (A). The seating for the drive shaft and the sprocket are in

the rear part (B). Hardware items are placed in the rails during transportation - remove these. Lay the front and rear rail

sections one behind the other.
1. Remove cable ties that secure belt/chain. On chain rails leave the transport lock (X) still in position until instructed to

remove it in section 9.
2. Pull apart the two rail sections completely in order to create a gap for the middle section (C). This rail is designed in such a

way so as to easily add the middle section. Slide the 2 connecting pieces (D) over the seams of the rail sections up to the

markings. To secure the connecting pieces,

bend the sheet metal lugs outwards with a suitable tool

. The assembly of the

rail is complete.

ASSEMBLING THE 3 PIECE SEGMENTED RAIL

8

X

Содержание ST50EVOB

Страница 1: ...reference ST50EVOB ST50EVOC Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING...

Страница 2: ...osed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors an appropriate reinforcement should be added To do so contact the door manufacturer or your local Steel...

Страница 3: ...s any binding or sticking 15 kgf is the absolute maximum allowable force to raise or lower the door in any position If your door binds sticks or is out of balance call a trained door technician or you...

Страница 4: ...e packed in a single carton 2 RAIL SIZES AVAILABLE 3 NOTE The Ceiling Fixing Point is measured back from the lintel see section 6 item 7 of completed installation Also allow 300 mm back from the fixin...

Страница 5: ...15 Centre rail bracket As you proceed with the assembly installation and adjustment procedures in this manual you may find it helpful to refer back to this illustration of a completed installation CO...

Страница 6: ...or when remote controls are not available Open Stop Close 7 LEDs 1 Remote Control Indicator 2 Program DOWN indicator Door Operating Passpoint indicator 3 Program UP indicator No Function Polarity Comm...

Страница 7: ...nd the hex head fixing 6 mm x 18 mm screws 5 This completes the assembly of the powerhead to the rail FASTEN RAIL TO OPENER 9 10 The segmented rail is largely preassembled and consists of 3 parts The...

Страница 8: ...previous section for proper placement of lintel bracket A Wall mount centre the lintel bracket 1 on the vertical centre line 2 with the bottom edge of the lintel bracket on the horizontal line 4 with...

Страница 9: ...ween door and rail 1 Raise the opener onto support 2 Open the door completely place a 50 mm spacer between the door and the rail as shown 3 The final positioning of the rail should be relatively paral...

Страница 10: ...ion the opener as in the previous step Check the rail is centred over the door Ensure the rail brackets fig 1 is on the Powerhead end of the rail in a position as close to the opener as possible X 2 I...

Страница 11: ...y need to be extended Attach the manual release Instruction Label to the cord as indicated in fig 1 DO NOT USE THE RED MANUAL RELEASE HANDLE TO OPEN AND CLOSE THE DOOR To operate the Manual Release 1...

Страница 12: ...door UP and DOWN if required 6 Press and release the P button to set the DOWN limit At this point the opener will operate a complete cycle AUTOMATICALLY This will set the force of the motor all LED i...

Страница 13: ...ses off the 40 mm high obstacle remove the obstacle and run the opener through a complete travel cycle Door must not reverse in closed position If it does repeat Program the Limits and Force then repe...

Страница 14: ...ry The wiring should exit from the bottom of the housing to maintain the correct IP rating and continued operation One sensor is a Sending Eye the other is a Receiving Eye Try to avoid positioning the...

Страница 15: ...ess Programming 14 22 1 service www chamber a n de nfo chamber a n de B B A 2 114A3361 For Service Call Installation Date 3 132A2900 RISK OF ENTRAPMENT Repeat Safety Reverse Test monthly Door must rev...

Страница 16: ...or opener 2 Press and release the S button The LED 1 indicator light will glow steadily 3 Enter a 4 digit personal identification number PIN of your choice on the keypad 4 Press and hold the ENTER but...

Страница 17: ...is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety reverse test Make any necessary adjustment...

Страница 18: ...oor fully closed Normal Torque 4 Nm Max door weight 100 kg Spring Balanced weight 15 kg Max door area Sectional door 13 0 m2 Motor Type DC gearmotor permanent lubrication Noise level 55 db at 1 metre...

Страница 19: ...erate from either door control or remote Does the opener have electric power Plug lamp into outlet If it doesn t light check the fuse box or the circuit breaker Some outlets are controlled by a wall s...

Страница 20: ...her electrical devices vi Preventative maintenance and regular servicing not undertaken vii Account not paid in full by the purchaser 11 We also provide the following statement required by the Austral...

Отзывы: