Failure analysis
PF166
Pfad \ Datei:
I:\Projekte\SOLAR\PV-Entw\FREEZER\_E5970_KS-solar-LHG\14_Service\Failure analysis.doc
Seite 1 von 5
Speicherdatum:
Bearbeiter: Gutzeit
The PF166 is running with extra low voltage. There is no risk during maintenance and testing
by high voltage. Nevertheless use isolated tools and a fuse in the battery cable to protect a
short circuit of the battery. Please prevent as well ESD.
1.
Check installation
Please check if the display shows any number or if the Minus-LED is
blinking
[40]
. If no display appears check battery connection:
•
polarity
•
broken fuse
•
damaged cable or connector
2.
Battery voltage
Please check if the battery voltage is higher than the cut-off voltage of the compressor. If
the battery voltage is below 10,4V or in between 17,0V and 22,8V the inverter box
[235]
is
disconnecting the compressor to protect the battery against deep discharge. So voltage had
to be between 10,4V and 17,0V in a 12V system or between 22,8V and 30,5V in a 24V
system.
The display
[90]
is already operating if the compressor
[230]
is disconnected by the inverter
box
[235]
. If the battery voltage is lower than the cut-of level, the LED connected to the
inverter box (between "+" and "D", see topic 5) is flashing one time.
After recharging the battery the compressor
[230]
will start automatically after reaching the
cut-in voltage.
Cut-off
Cut-in
12V battery
10,4V
11,7V
24V battery
22,8V
24,2
°C
°C
°F
°F
electronic
thermostat with
user interface
GTC
inverterbox with
speed control
101N0300