Страница 1: ......
Страница 2: ...battery voltage is higher than the cut off voltage of the compressor If the battery voltage is below 10 4V or in between 17 0V and 22 8V the inverter box 235 is disconnecting the compressor to protec...
Страница 3: ...inverter and compressor To open the ventilation grille 500 on the right side you had first to remove the plastic cover 520 from the screws 510 After removing the cover 520 you can unscrew with TORX T1...
Страница 4: ...k T and blue C cable If the inverter box 235 is connected to the battery and if the battery voltage is higher than the cut off voltage the compressor 230 must start suddenly after disconnecting C and...
Страница 5: ...rror Inverter box Compressor is not running Display could be out of order 5 thermal cut out Inverter box Compressor is not running Electronic is connected direct to battery by connecting C and togethe...
Страница 6: ...erdatum Bearbeiter Gutzeit Than you can open the top 50 of the opener to get access to the display electronic 40 Disconnect the connectors of the temperature sensor on the right side and the connector...