5 Installation
Avoid installation locations in direct sunlight, or next to stoves, heating, or
similar heat sources.
The floor at the installation location should be level and flat. Install the device
a sufficient distance from the wall so that the lid can open and close unhin-
dered.
Do not cover the gap between the lower edge of the cabinet and the floor,
because the chiller must be provided with cooling air.
The minimum clearance between the ventilation grill and the wall is 20 cm.
This clearance must always be maintained and the ventilation grill must not
be covered.
Do not alter the outer cladding of the device. A minimum all-round clearance
of 20 mm must be maintained to ensure adequate heat dissipation.
According to the EN 378 standard, the installation room for the device must
have a volume of 1 m³ per 8 g of R 600a coolant, so that if a leak develops in
the cooling circuit no inflammable gas-air mixture can result in the installation
room. Information on the coolant volume can be found on the type plate.
Do not connect the device together with other devices using an extension
cable - danger of overheating.
Take note of the cable cross-section information in the table below when extend-
ing the power cable.
6 Connection
The power type and voltage at the installation location must match the specifi-
cations on the type plate. The type plate is located on the upper right side wall
of the cabinet.
WARNING
Risk of electrical shock and fire when connected to a voltage supply outside
the specified range.
The cable provided must be connected to a 12 V or 24 V DC connection at the
battery or the charge controller.
Please pay attention to the correct polarity: blue (-) and red (+).
NOTE
Energy saving
Avoid long and unnecessary opening of the lid.
Allow warm food to first cool to room temperature before storing it in the
device.
Defrost the device when an ice layer has formed. This improves the cooling
transfer and reduces the energy consumption.
•
•
•
•
•
•
•
•
Cable sizes
12 V
Cable length
24 V
Cable length
Cross-section
AWG
mm²
Gauge
m
ft.
m
ft.
2.5
12
2.5
8
5
16
4
12
4
13
8
26
6
10
6
19.5
12
39