6
760.180 | 17.10
ENGLISH
5 Installation
• Avoid installation locations in direct sunlight, or next to stoves, heating, or
similar heat sources.
• The floor at the installation location should be level and flat. Install the device
a sufficient distance from the wall so that the lid can open and close unhin-
dered.
• Do not cover the
gap between the lower edge of the cabinet and the floor,
because the chiller must be provided with cooling air.
• The minimum clearance between the ventilation grill and the wall is 20 cm
.
This clearance must always be maintained and the ventilation grill must not
be covered.
• Do not obstruct the outer cladding of the device. A minimum all-round clear-
ance of
20 mm must be maintained to ensure adequate heat dissipation.
• According to the EN 378 standard, the installation room for the device must
have a volume of 1 m³ per 8 g of R 290 coolant, so that if a leak develops in
the cooling circuit no inflammable gas-air mixture can result in the installation
room. Information on the coolant volume can be found on the type plate.
• Do not connect the device together with other devices using an extension
cable – danger of overheating.
• Take note of the cable cross-section information in the table below when extend-
ing the power cable.
Cable sizes
12 V
Cable length
24 V
Cable length
Cross-section
AWG
mm²
Gauge
m
ft.
m
ft.
2.5
12
2.5
8
5
16
4
12
4
13
8
26
6
10
6
19.5
12
39
6 Connection
The power type and voltage at the installation location must match the specifi-
cations on the type plate. The type plate is located on the upper right side wall
of the cabinet.
WARNING
Risk of electrical shock and fire when connected to a voltage supply outside
the specified range.
X
The cable provided must be connected to a 12 V or 24 V DC connection at the
battery or the charge controller.
X
Please pay attention to the correct polarity: blue (−) and red (+).
NOTES
Energy saving
X
Avoid long and unnecessary opening of the lid.
X
Allow warm food to first cool to room temperature before storing it in the
device.
X
Defrost the device when an ice layer has formed. This improves the cooling
transfer and reduces the energy consumption.
Operation as refrigerator
X
If the device is used as a refrigerator (inside temperature above 0 °C / 32 °F),
humidity will condense on the interior container.
Drain condensed water periodically (see chapter 13 Defrosting). Do not store
moisture-sensitive goods directly on the bottom of the refrigerator but in a
basket or with distance to the bottom.
Содержание PF166-H
Страница 15: ...760180...