Daily Program Number
Keypad lock
Clock
Max Temperature/Current
Temperature for Room 1
Idle Temp
24/7 Event Programming
buttons
Timer/Temperature setting
buttons
Lock Button
Time of day setting
Max/Idle/Off mode indicator
Day of the week indicator
AM/PM indicator
Max Temperature/Current
Temperature for Room 2
0-60 Minute Max Cycle Timer
05/13
Pub. No. 601-C
- 10 -
Figure 8 - Manager & User Control
User Idle/Max Display
Idle/Max Button
Owners Manual
Digital Commercial Control Package Operation
Models: HC-9 thru HC-24 with DCCP Control
(d) MAX CYCLE TIMER is used to set the duration
that the system will be in MAX TEMP mode
after the USER BYPASS CONTROL button is
pressed in. It is set by pressing the correspond-
ing button on the Digital Command Center.
Each time the button is pressed the minutes will
increase in one minute increments from “:00” to
“:60”. If the MAX CYCLE TIMER is programmed
to “:00”, this feature will be disabled and the
USER BYPASS CONTROL(S) will be disabled.
(e) Degree °C or °F change is made by placing a
jumper over the CN112 pins for °C or by
removing it for °F (Jumper not included). The
power must be OFF when making this change.
See Command Module on Wiring Diagram
page 14.
3) SET EVENT: Before programming the SET
EVENT, it is necessary to determine the hours
the steam bath will operate and in which mode.
Each day of the week can have up to six events
programmed. The chart on the following page
will help organize your plan for the SET EVENT
function. The top 2 sections of the chart are
filled in with 2 examples
NOTE:
Program #1 is set to 12:00am by default.
This time cannot be altered. You can however set
12:00am to: OFF, IDLE, or MAX.
®
®
!