Digital Commercial Control Package Operation
VII. Digital Commercial Control Package Operation:
This control is designed to maximize energy savings by
allowing the facility manager set a lower operation
temperature called IDLE TEMP and also satisfy the
steam bather with the ability to by-pass this feature on
demand by pressing the USER BYPASS CONTROL
button. Unlike a typical 24 /7 timer which has only an ON
or OFF mode, the Digital Command Center has three
modes MAX, IDLE and OFF. MAX is the normal ON
mode reserved for peak hours of use when the steam
room is held at the optimum steam bath temperature.
IDLE mode is the energy saving mode. IDLE is set
below the MAX temperature and provides a significant
energy savings. As needed, the steam bather can easily
switch to the MAX setting by pressing the button on the
USER BYPASS CONTROL.
A) USER BYPASS CONTROL: The USER BYPASS
CONTROL button is only functional during the IDLE
mode. In the IDLE mode the USER BYPASS
CONTROL, typically mounted at the entrance to the
steam room, is waiting for the user to press the
button and select the MAX mode. IDLE mode is
indicated on the USER BYPASS CONTROL by one
lit bar. Pressing the USER BYPASS CONTROL
button starts the MAX CYCLE TIMER and immedi-
ately begins to heat the room to the MAX setting.
This temporary MAX CYCLE TIMER is program-
mable up to 60 minutes by the facility manager.
MAX TEMP mode is indicated by all bars lit. When
the Digital Command Center is set to MAX TEMP
the USER BYPASS CONTROL icon displays max
(all bars lit). In the MAX TEMP mode the USER
BYPASS CONTROL buttons do not function. When
the DIGITAL COMMAND CENTER is in the OFF
mode the USER BYPASS CONTROL icon will be off
(no bars lit) and the user buttons do not function.
B) Programming the DIGITAL COMMAND CENTER
can be broken down into 3 separate sections, SET
EVENT, SET VALUE, and SET CLOCK. The
buttons on the control are grouped accordingly. SET
EVENT is used to set the time and day that a
particular mode (MAX, IDLE, or OFF) is to begin.
SET VALUE is intended to set the MAX and IDLE
temperature as well as the MAX CYCLE TIMER.
The SET CLOCK section is only for adjustment of
the current time and day. The DIGITAL COMMAND
CENTER display light comes on when any button is
pressed. The light will remain on for 5 minutes after
the last button is pressed.
1) SET CLOCK: The SET CLOCK section of the
Digital Command Center is used exclusively for
setting the current time and day. It is a conve-
nient place to make changes for daylight
savings time without having to reprogram other
settings. The clock has a battery backup in the
Control Module that will keep time for up to one
year with no power.
(a) DAY Setting: Press the lower DAY button
to toggle the current day of the week.
(b) HOUR Setting: Press the lower HOUR
button to select the current AM or PM hour
and the correct hour will be displayed.
(c) MINUTE setting: Press the Lower MINUTE
button until the correct minute is displayed.
2) SET VALUE: The SET VALUE section of the
keypad is used to program the following 4
parameters:
(a) MAX1 TEMP is used to set the maximum
desired operating temperature of the
steam bath. It is set by pressing the button
until the preferred maximum temperature is
displayed. Note: The MAX TEMP cannot
be set lower than the IDLE TEMP. Selec-
tion of the MAX TEMP setting is at the
discretion of the facility manager.
(b) MAX2 TEMP (only available with SRP) is
used to set the desired operating tempera-
ture of a second steam room. It is
programmed the same as MAX1 TEMP.
(c) IDLE TEMP is used to program a lower
temperature setting during periods of less
frequent usage. It is set by pressing the
button until the desired set-back tempera-
ture is displayed. The feature can be
disabled by setting it to 00.The IDLE TEMP
cannot be set higher than the lowest MAX
TEMP value.