User Idle/Max Display

Idle/Max Button

Digital Commercial Control Package Operation

VII. Digital Commercial Control Package Operation:

This control is designed to maximize energy savings by 
allowing the facility manager set a lower operation 
temperature called IDLE TEMP and also satisfy the 
steam bather with the ability to by-pass this feature on 
demand by pressing the USER BYPASS CONTROL 
button. Unlike a typical 24 /7 timer which has only an ON 
or OFF mode, the Digital Command Center has three 
modes MAX, IDLE and OFF. MAX is the normal ON 
mode reserved for peak hours of use when the steam 
room is held at the optimum steam bath temperature. 
IDLE mode is the energy saving mode. IDLE is set 
below the MAX temperature and provides a significant 
energy savings. As needed, the steam bather can easily 
switch to the MAX setting by pressing the button on the 
USER BYPASS CONTROL. 

A) USER BYPASS CONTROL: The USER BYPASS 

CONTROL button is only functional during the IDLE 
mode. In the IDLE mode the USER BYPASS 
CONTROL, typically mounted at the entrance to the 
steam room, is waiting for the user to press the 
button and select the MAX mode. IDLE mode is 
indicated on the USER BYPASS CONTROL by one 
lit bar. Pressing the USER BYPASS CONTROL 
button starts the MAX CYCLE TIMER and immedi-
ately begins to heat the room to the MAX setting. 
This temporary MAX CYCLE TIMER is program-
mable up to 60 minutes by the facility manager. 
MAX TEMP mode is indicated by all bars lit. When 
the Digital Command Center is set to MAX TEMP 
the USER BYPASS CONTROL icon displays max 
(all bars lit). In the MAX TEMP mode the USER 
BYPASS CONTROL buttons do not function. When 
the DIGITAL COMMAND CENTER is in the OFF 
mode the USER BYPASS CONTROL icon will be off 
(no bars lit) and the user buttons do not function.

B) Programming the DIGITAL COMMAND CENTER 

can be broken down into 3 separate sections, SET 
EVENT, SET VALUE, and SET CLOCK. The 
buttons on the control are grouped accordingly. SET 
EVENT is used to set the time and day that a 
particular mode (MAX, IDLE, or OFF) is to begin. 
SET VALUE is intended to set the MAX and IDLE 
temperature as well as the MAX CYCLE TIMER. 
The SET CLOCK section is only for adjustment of 
the current time and day. The DIGITAL COMMAND 
CENTER display light comes on when any button is 
pressed. The light will remain on for 5 minutes after 
the last button is pressed. 

1) SET CLOCK: The SET CLOCK section of the 

Digital Command Center is used exclusively for 
setting the current time and day. It is a conve-
nient place to make changes for daylight 
savings time without having to reprogram other 
settings. The clock has a battery backup in the 
Control Module that will keep time for up to one 
year with no power.

(a) DAY Setting: Press the lower DAY button 

to toggle the current day of the week. 

(b) HOUR Setting: Press the lower HOUR 

button to select the current AM or PM hour 
and the correct hour will be displayed. 

(c) MINUTE setting: Press the Lower MINUTE 

button until the correct minute is displayed. 

2) SET VALUE: The SET VALUE section of the 

keypad is used to program the following 4 
parameters:

(a) MAX1 TEMP is used to set the maximum 

desired operating temperature of the 
steam bath. It is set by pressing the button 
until the preferred maximum temperature is 
displayed. Note: The MAX TEMP cannot 
be set lower than the IDLE TEMP. Selec-
tion of the MAX TEMP setting is at the 
discretion of the facility manager.

(b) MAX2 TEMP (only available with SRP) is 

used to set the desired operating tempera-
ture of a second steam room. It is 
programmed the same as MAX1 TEMP. 

(c) IDLE TEMP is used to program a lower 

temperature setting during periods of less 
frequent usage. It is set by pressing the 
button until the desired set-back tempera-
ture is displayed. The feature can be 
disabled by setting it to 00.The IDLE TEMP 
cannot be set higher than the lowest MAX 
TEMP value. 

10/08

Pub. No. 600-A

- 6 -

Figure 5 - User Control Panel

Содержание HC-12

Страница 1: ...80 100 120 140 60 40 20 0 psi ...

Страница 2: ...ontrol Package Operation VIII Warranty information List of Illustrations Warning Sign Figure 1 Dimensional Drawing for Heavy Commercial Steam Generator HC 9 thru HC 18 Figure 2 Cables Figure 3 Typical Steam Generator Installation Figure 4 Sensor Installation Inside Steam Room Figure 5 User Control Panel Figure 6 Main Control Panel Programming Examples Specifications Chart Wiring Diagram Page 1 1 2...

Страница 3: ...nd the causes symptoms and effects of hyperthermia which may be described as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F The symptoms of hyperthermia include an increase in the internal temperature of the body dizziness lethargy drowsi ness and fainting The effects of hyperthermia include 1 Failur...

Страница 4: ...n the back of this manual C Provide an inline fuse circuit breaker as required sized in accordance with specification plate Do not install a GFI Ground Fault Interrupter to this equip ment D Select a location to install the generator to allow sufficient room See Access Area Requirements for access to the unit in the event service is required Select a clean dry indoor location protected from freezi...

Страница 5: ... an optional auto blow down assembly must be provided to route to an indirect waste 1 Rough in a water line from a cold water pipe Provide a local shut off valve 2 Rough in the steam line using 3 4 copper tubing Do NOT use iron or galvanized pipe it will rust and discolor wall of steam room For a steam line that is longer than 10 feet use an appropriate pipe insulation rated for a minimum of 212ºF...

Страница 6: ...or is designed to be used ONLY in an upright and level position to do otherwise would damage the unit and void the warranty For convenient access mount the steam generator on the optional Steamist stand designed specifically for the steam generator 1 Water supply Purge the water supply line before connecting to the steam generator In areas where high water pressure may be a problem a water hammer ...

Страница 7: ...oom 2 It is very important to pay special attention not get the connection to room 1 and room2 crossed This will be very difficult to troubleshoot If the generator is configured for one room there will not be any special markings B USER BYPASS CONTROL s The USER BYPASS CONTROL should be located outside the steam room door convenient to the bather This control gives the bather limited control of th...

Страница 8: ...o 3 separate sections SET EVENT SET VALUE and SET CLOCK The buttons on the control are grouped accordingly SET EVENT is used to set the time and day that a particular mode MAX IDLE or OFF is to begin SET VALUE is intended to set the MAX and IDLE temperature as well as the MAX CYCLE TIMER The SET CLOCK section is only for adjustment of the current time and day The DIGITAL COMMAND CENTER display lig...

Страница 9: ...l help organize your plan for the SET EVENT function The top 2 sections of the chart are filled in with 2 examples 10 08 Pub No 600 A 7 d MAX CYCLE TIMER is used to set the duration that the system will be in MAX TEMP mode after the USER BYPASS CONTROL button is pressed in It is set by pressing the corresponding button on the Digital Command Center Each time the button is pressed the minutes will ...

Страница 10: ...IDLE all day until 10PM when the club closes This would yield maximum energy savings and is the recom mended program At any time the system is in IDLE mode the user can activate the MAX TEMP mode by pressing the USER BYPASS CONTROL button Photo copy the chart and use it as a work sheet to plan you settings PROG 1 2 3 4 5 6 EXAMPLE 1 MAX IDLE OFF X X X X X X TIME 7 00AM 8 00AM 10 00AM 3 00PM 7 00PM...

Страница 11: ...utton and toggling through the programs and toggling through the days of the weeks and observing the time settings If you made no changes simply press the enter button to return to normal or it will return in 30 seconds d Programming Tip When reviewing the program and a block of days are selected if all the individual programs for those days do not match the clock will display This is normal and a...

Страница 12: ... be above the IDLE setting When all these condi tions are met then the aroma relays will energize 10 Fahrenheit and Celsius The Fahrenheit or Celsius temperature can be selected by changing a jumper in the Command Module CN109 When it is not connected open circuit it will be Fahrenheit When it is connected it will be Celsius The Jumper must be switched with power off See wiring diagram on page 11 ...

Страница 13: ...Control Fuses YL GN GN BN BK BK RD RD BK RD OR VT YL RD GY VT BN BN BK BL BL RD BK BL BN BK RD WT GY Steam1 Steam2 Heater Aroma1 Aroma2 Drain 120V 15AMP Branch Circuit H N 1 2 BK14 WT14 RD14 RD14 Pressure Limit Control F2 F1 50 Cable 50 Cable 50 Cable CN102 CN105 CN103 CN106 CN104 CN109 Back up Battery Note CN109 Jumper open F Jumper closed C Turn OFF power if making this change RD RD BK BK BN Not...

Страница 14: ......

Отзывы: