12
Q-Logic™ Joystick Setup
15.0
Q-Logic 2
15.1
Joystick Setup
Center Deadband
Axis Deadband
The Axis Deadband parameter defines how far the joystick has to move to be
recognized. This can be helpful, if a toggle command has to be made.
Select
m: Axis Deadband
option with the navigation’s
Up
&
Down
buttons, then
press the
Right
button.
Use the
Plus & Minus ±
buttons to adjust the Axis Deadband. Adjustment ranges
from 5 to 50%. Press
Left
navigation button to save.
1. Plug in the Q-Logic™ Handheld Programmer to the Q-Logic™ ED (Enhanced Display)
or to the standalone joystick if SCIM (Specialty Control Input Module - Figure 1)
is in use.
2. On the Q-Logic™ Programmer, navigate to
Program Adjustments
Specialty Control
Proportional Joystick Set Ups Proportional
. Here you can fine tune joystick
performance and functionalities such as:
Center and Axis Deadband
Tremor Suppression
Assign Direction
Joystick Calibration and Throw
Switch Operation
The Center Deadband parameter defines how far the joystick must be moved from
neutral position to engage moving the power chair. The value corresponds to the
diameter of a circle around the joystick center position. No drive or menu instruction will
be executed unless the joystick is moved out of this circle.
Select
m: Center Deadband
option with the navigation’s
Up & Down
buttons, then
press the
Right
button.
Use the
Plus & Minus ±
buttons to adjust the
Center Deadband
. Adjustment ranges
from 5 to 50%. Press
Left
navigation button to save.
Содержание IDM-ALLROUND-9