11

TROUBLESHOOTING

The motor will

not run or start.

POSSIBLE CAUSE

PROBLEM

SOLUTIONS

The motor runs

continuously

when the

ON/OFF

switchis in the

ON position.

The regulator

does not

regulate the

pressure.

The power cord is not plugged in.
The on/off switch is in the O (OFF) 

position.
The extension cord is the wrong wire 

gauge or is too long.

The motor’s thermal overload 

protection has tripped.

A fuse has blown or a circuit breaker 

has been tripped.

The air tank pressure exceeds the 

preset pressure switch limit.
The safety valve is stuck open.
Electrical connections are lose.

The motor, capacitor or safety valve is 

defective.
The ON/OFF switch does not shut off 

the motor when the air compressor 

reaches the cut-out pressure and the 

safety valve activates. 

The compressor’s capacity is not 

enough.

The regulator or its internal parts are 

dirty or damaged.

Plug the power cord into a grounded outlet.
Set the on/off switch to the ON position.

Check extension cord information for the proper 

wire gauge and cord length.
Turn the air compressor off, unplug the power 

cord and wait until the motor has cooled down. 

Plug in the power cord only after the motor has 

cooled down, and wait at least 5 minutes to make 

sure the thermal overload protector has 

recovered.
Replace the fuse or reset the circuit breaker.
Verify that the fuse has the proper amperage.
Check for low voltage conditions.
Disconnect any other electrical appliances from 

the circuit or operate the compressor on a 

dedicated circuit.
The motor will start automatically when the tank 

pressure drops below the cut-in pressure.
Clean or replace the safety valve.
Contact an authorized service center, or call 

1-888-899-0146

.

Contact an authorized service center, or call 

1-888-899-0146.
Set the ON/OFF switch to the OFF position. If the 

motor does not shut off, unplug the air 

compressor. If the pressure switch is defective, 

replace it.
Check the air requirements of the accessory that 

is being used. If it is higher than the CFM (Cubic 

Feet per Minute) and pressure supplied by the 

compressor (page 2), a larger capacity air 

compressor is needed.
Most accessories are rated at 25% of actual CFM 

while running continuously.

Replace the regulator.

Содержание 3330881

Страница 1: ...pressor To Reduce The Risk Of Injury User Must Read And Understand Operator s Manual Save These Instructions For Future Reference Toll Free Helpline OPERATOR S MANUAL CAUTION 1 888 899 0146 Product Model SAQ 1815 Item 3330881 ...

Страница 2: ...ons Read all instructions and follow them with use of this product CFM Cubic Feet per Minute This compressor is rated in accordance with ISO 1217 displacement compressors acceptance tests TECHNICAL SPECIFICATIONS PRODUCT NUMBER RUNNING HORSEPOWER TANK SIZE TOTAL AIR DELIVERY CFM 40PSI AIR DELIVERY CFM 90PSI CUT IN PRESSURE PSI CUT OUT PRESSURE PSI PUMP DESIGN MOTOR POWER WEIGHT POWER CORD 3330881 ...

Страница 3: ... sure that the procedure work method or operating technique that you choose does not render the compressor unsafe The safety alert symbol indicates a potential hazard to personal injury A signal word DANGER WARNING or CAUTION is used with the alert symbol to designate a degree or level of hazard seriousness A safety symbol may be used to represent the type of hazard The signal word NOTICE is used ...

Страница 4: ...serious injury Risk of serious eye injury Always wear ANSI Z87 1 approved safety goggles when using air compressor Do not spray any part of the body Shock risk could result in death or serious injury Only connect compressor to a properly grounded receptacle KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES Dust can be created when cutting sanding drilling or grinding materials such as wood p...

Страница 5: ...ir Pressure Regulator G Outlet Pressure Gauge F Tank Pressure Gauge D ON OFF Switch H Quick Coupler B Air Compressor Pump A Electrical Motor J Air Tank I Drain Valve C Safety Valve D J H F E G A B K C I KEY PARTS DIAGRAM ...

Страница 6: ...kwise to decrease the pressure Tank Pressure Gauge The gauge measures the pressure level of the air that is stored in the tank It cannot be adjusted by the operator and it does not indicate the pressure inside the line Outlet Pressure Gauge The gauge measures the regulated outlet pressure Quick Coupler The quick coupler is connected to a quick connector which is connecting to air hose Drain Valve ...

Страница 7: ...e air hose 1 to the compressor s quick coupler 2 with the quick conncetor 3 Fig B Air hose and quick connector are not provided need to be purchased sepa rately Apply plumber s tape on all the threads to prevent air leakage 1 2 3 1 High pressure air could result in death or serious injury Never operate above maximum operating pressure of the spray gun or tool Hot compressor surfaces could result i...

Страница 8: ...ing in the unit is noly requiresd prior to first use Fig F After 30 minutes turn off the ON OFF switch Close the tank drain valve 1 by turning it clockwise Fig G Set the ON OFF switch to the ON position The air receiver will fill to cut out pressure and then the compressor s motor will stop The compressor is now ready for use Use a dedicated circuit The compressor will use the full capacity of a t...

Страница 9: ...ed pressure is reached The compressor is ready for use Set the ON OFF switch 1 to the OFF position Unplug the power cord 2 Reduce the pressure in the tank through the outlet hose Pulling the safety valve ring 3 and keeping it open will also reduce the pressure in the tank Fig L Set the tank drain valve 1 to ON to ensire tank is drained Fig K 2 3 4 1 4 3 2 1 Fig H OFF 1 Fig I 1 CAUTION To avoid per...

Страница 10: ...nect and wind up the power cord Clean the ventilation openings on the motor enclosure with a damp cloth Drain all moisture from the tank Pull the pressure safety valve to release all pressure from the tank WARNING Storage covers could cause a fire resulting in death or serious injury Store the air compressor in a clean and dry location In cold weather store the compressor in a warm building when i...

Страница 11: ... gauge and cord length Turn the air compressor off unplug the power cord and wait until the motor has cooled down Plug in the power cord only after the motor has cooled down and wait at least 5 minutes to make sure the thermal overload protector has recovered Replace the fuse or reset the circuit breaker Verify that the fuse has the proper amperage Check for low voltage conditions Disconnect any o...

Страница 12: ...dequate Cooling surfaces are dirty The valve is leaking Check the fittings with soapy water Tighten or reseal leaking fittings apply plumber s tape on threads Do not over tighten Close the drain valve Clean or replace the air filter element Decrease the amount of air used Check the air hose and replace it if necessary Replace the tank immediately Do not attempt to repair it Check for worn parts an...

Страница 13: ...13 EXPLODED VIEW ...

Страница 14: ... M8 Latch Assembly Wheel Assembly Tank Bolt M8x40 Bonnet Drain Valve Handle Assembly 1 1 2 2 4 4 1 1 2 2 1 Description Qty No 12 13 14 15 16 17 18 19 20 21 Rubber Mat Safety Valve Power Cord End Cap Check Valve Bolt M5x12 Flange Nut M5 Pressure Switch Control Panel Unloading Aluminum Tube 2 1 1 1 1 1 4 4 1 1 ...

Страница 15: ...ddress below and call 1 888 899 0146 for instructions prior returning this item to the store or sending back to We will inspect the product and contact you within 72 hours to give you the results of our inspection We reserve the right to repair or replace the product at our discretion However we may replace the product with one of similar but not exact features Parts and Service Information availa...

Отзывы: