Quickstart operating instructions
Hydraulic Tester PPC-06/08/12
WALTER STAUFFENBERG GMBH & CO.KG
Im Ehrenfeld 4 D-58791 Werdohl
Postfach 1745 D-58777 Werdohl
Germany
Telefon: +49 (0) 2392 / 916 - 0
Telefax: +49 (0) 2392 / 2505
E-Mail:
Internet:
This
Quickstart operating manual
will allow the use of some basic PPC features in a few steps. For full operating
details - e.g. storing results, online measurements, view the complete operating instructions for PPC-06/08/12.
1. The PPC-06/08/12
1.
„ON / OFF“
press and hold to start the PPC-06/08/12
2.
„SETUP / OPTION“
change the System setup
3.
„arrow keys“
select function value
4.
„arrow keys“
select function value
5.
„START / ENTER:
„START“
starts measurement recording
„ENTER“
selects functions and stores changed
parameters
6.
„STOP / ESC“:
„STOP“
stops the recording of measurements
„ESC“
stops selection of parameters and close menus
!!! Changed settings are memorized after selecting „ESC“ !!!
7.
„I1-I2 / I1=I2“
calculates the difference between channel 1
and Channel 2. The difference „
Δ
“ is displayed
instead of channel 2. By selecting
I1=I2
channel 2 can be aligned with channel 1.
8.
„TEMP“
pressing and holding shows the temperature of
all channels
9.
„DATA OUTPUT“
starts the data transfer to PC, printer or display
10.
„RECORD“
records measurements to internal memory
11.
„MIN/MAX ACTUAL / RESET“:
„MIN/MAX ACTUAL“
switching between ACT, MIN and MAX -display
„RESET“
deletes MIN/MAX-values
12.
„SENSOR INPUTS“
up to 6 inputs, according to device type
13.
„LOW.VOLTAGE SOCKET“
external voltage supply and battery
charging
14.
„DATA OUTPUT SOCKET“
connection of external instruments like PC,
printer etc.
15. The „
Graphic LCD Display
“ shows measurement values, settings
and
graphics.
2. Operation
All PPC-06/08/12 operations are selected on the keypad. To open the required menus press the corresponding
keys. With the
"arrow keys"
(3/4) you can move the cursor through the menu. After selecting a menu, press the
"ENTER" -key
(5) to allow further options.
3. Connecting the power supply and recharging the battery
The power supply is to be connected to the
„LOW VOLTAGE SOCKET“
(13)
. The PPC-06/08/12 utilizes an
internal battery which is automatically recharged during operation with power supply connected; Full recharge
takes approximately five hours of charge time.
4. Connecting the sensors and turning on the PPC-06/08/12
The provided sensors are connected to the sensor inputs. The red marks on the plug and socket must line up. To
start, press and hold
"ON / OFF" key
(1)
until unit turns on. The sensors are automatically recognized and the
measured values are shown on the display.
Technical Subject to change
November 2006