FD50
35
36
37
Ø
27 mm - 35 mm
Ø
35 mm - 50 mm
30
J1
Montaggio piatto
RobiFix-B..-ZEM (con FD50, con WST-TS150)
J1
Flat mount
RobiFix-B..-ZEM (with FD50, with WST-TS150)
RobiFix-B-ZEM viene utilizzato quando occorre realizzare un’in-
terfaccia tra un cavo inguainato (2+PE) e tre conduttori unipolari
Il montaggio piatto si effettua esternamente al robot, direttamente
sulla base di quest’ultimo
RobiFix-B-ZEM is used where an interface between a jacketed
cable (2+PE) and 3 separate conductors is needed
Flat mounting is effected outside the robot, directly on the
robot base
RobiFix-B..-ZEM con FD50
RobiFix-B..-ZEM with FD50
RobiFix-B..-ZEM con WST...
RobiFix-B..-ZEM with WST...
Vedasi MA200
Observe MA200
WST-TS150 (30.0021)
ordinare separatamente
order separately
RobiFix-B..-ZEM con FD50
RobiFix-B..-ZEM with FD50
(ill. 35)
Adatto a cavi con Ø esterno
27– 35 mm.
Inserire il cacciavite nella scanalatura
della tenuta FD50
(ill. 35)
Suitable for cable of outside Ø
27 - 35 mm
Insert screwdriver in release groove of
seal FD50
(ill. 36)
e sollevare la calotta di tenuta
Se il diametro del cavo è inferiore a
27 mm, utilizzare una guaina termo-re-
stringente con colla all‘interno
(ill. 36)
and lever out sealing cover
If cable diameter is smaller than
27 mm, use a shrink-on sleeve with
inside adhesive coating
(ill. 37)
Spingere la calotta FD50 fino all’estre-
mità del cavo
Per cavo Ø > 30 mm leggermente
lubrificato con Klüberlectric KR 44-402,
N° di codice 731056
(ill. 37)
Push seal FD50 over end of cable
For cable Ø > 30 mm slightly lubricate
with Klüberlectric KR 44-402,
Order No 731056