The oil is to be changed every 5000 hours of operation or every years.
ATTENTION
The oil used for oil change must be new.
The period between oil changes can not be extended.
Note :
Filtering, recycling or other treatment of the oil can not extend the period between oil
changes.
Oil change:
IMGT3994
-
Unscrew the drain valve (1) or fit the drain connection (2) on the drain valve (1).
-
Recover the oil in a recipient.
Clean-up:
-
Clean the frame of the cam motion and ensure that all possible contamination has been
removed.
Filling:
-
Remove the drain coupling (2).
-
Seal the drain valve (1) with Loctite 518 before replacing it or remove the drain
coupling (2).