D2275-02-02 SEM315 CN4978 WEB User guide 

 

 

 

 

 

 

 

 

 

 

 

 

SEM315 

 

 

DIN RAIL HART 

® 

 TEMPERATURE TRANSMITTER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Status Instruments Ltd, Green Lane Business Park, Tewkesbury, Glos. GL20 

8DE 

      Tel: +44 (0)1684 296818   

   Fax: +44 (0)1684 293746 

Email: [email protected]   

   Web: www.status.co.uk 

 

 

 

 

 

 

 

 

INDEX 

 

 

 

 

 

SECTION 

CONTENTS 

PAGE NO. 

 

 

 

1.0 

DESCRIPTION 

2.0 

SPECIFICATION 

1-3 

3.0 

INSTALLATION 

4-5 

4.0 

HART PROGRAMMING 

5-7 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SEM315

Страница 1: ...TTER Status Instruments Ltd Green Lane Business Park Tewkesbury Glos GL20 8DE Tel 44 0 1684 296818 Fax 44 0 1684 293746 Email sales status co uk Web www status co uk INDEX SECTION CONTENTS PAGE NO 1 0 DESCRIPTION 1 2 0 SPECIFICATION 1 3 3 0 INSTALLATION 4 5 4 0 HART PROGRAMMING 5 7 ...

Страница 2: ...e X 3 User defined Linearisation BS EN60584 01 BS 4937 IEC 584 1 multi segment Polynomials Basic Measurement Accuracy 2 0 04 FRI 0 04 RDG or 0 5 C whichever is greater Thermal Drift Span 0 01 C Cold Junction Error 0 5 C Cold Junction Tracking 0 05 C C Cold Junction Range 40 to 85 C Page1 2 3 MILLIVOLT INPUT Input Voltage Source Range 10 to 75 mV Characterisation Linear Custom X 3 Minimum Span 5 mV...

Страница 3: ... be mounted in any orientation Care must be taken when locating the transmitter to ensure the ambient temperature remains within the specified operating range Figure 1 shows the mechanical layout of the transmitter Fig 1 All Dimensions in mm 3 2 ELECTRICAL Connections to the transmitter are made to the tension clamp terminals provided on the front face Output signal wiring should use screened twis...

Страница 4: ...g terminals as shown 4 0 HART PROGRAMMING Consult HART website for more details www hartcomm org 4 1 CONNECTION ARRANGEMENT FOR HART COMMUNICATOR Fig 3 1a Page 5 Fig 3 1b 4 2 CONNECTION ARRANGEMENTS FOR HART MODEM e g M CONFIG Fig 3 2a Page 6 R 250 L mA Current Meter Power Supply Black Connector HART Modem To PC 1 2 Red Connector ...

Страница 5: ...or or HART modem across the load in Figure 3 1a and 3 2a respectively Page 7 ALSO AVAILABLE Smart In Head Temperature Transmitters Din Rail Mounted Temperature Transmitters Panel Field Temperature Indicators Temperature Probes Trip Amplifiers Signal Conditioners And many other products For further information on all products Status Instruments Ltd Green Lane Business Park Tewkesbury Glos GL20 8DE ...

Отзывы: