background image

D2272-02-05 CN5219 SEM310  WEB User Guide 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

SEM310 

 
 
 

HART 

® 

IN HEAD TEMPERATURE TRANSMITTER

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Status Instruments Ltd, Status Business Park, Tewkesbury, Glos. GL20 8FD 

      Tel: +44 (0)1684 296818       Fax: +44 (0)1684 293746 

Email: [email protected]       Web: www.status.co.uk 

 
 

 
 
 
 
 

 

INDEX 

 
 
 
 
 

SECTION 

CONTENTS 

PAGE NO. 

 

 

 

1.0 

DESCRIPTION 

2.0 

SPECIFICATION 

1-5 

3.0 

INSTALLATION 

6-7 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание SEM310

Страница 1: ...RATURE TRANSMITTER Status Instruments Ltd Status Business Park Tewkesbury Glos GL20 8FD Tel 44 0 1684 296818 Fax 44 0 1684 293746 Email sales status co uk Web www status co uk INDEX SECTION CONTENTS PAGE NO 1 0 DESCRIPTION 1 2 0 SPECIFICATION 1 5 3 0 INSTALLATION 6 7 ...

Страница 2: ...L 100 to 600 25 TC Type N 180 to 1300 50 TC Type X 3 User defined Linearisation BS EN60584 01 BS 4937 IEC 584 1 multi segment Polynomials Basic Measurement Accuracy 2 0 04 FRI 0 04 RDG or 0 5 C whichever is greater Thermal Drift Span 0 01 C Cold Junction Error 0 5 C Cold Junction Tracking 0 05 C C Cold Junction Range 40 to 85 C Page1 2 3 MILLIVOLT INPUT Input Voltage Source Range 10 to 75 mV Chara...

Страница 3: ...to identify the equipment as suitable for Hazardous area use The equipment must be installed and maintained in accordance with local requirements for electrical equipment for use in potentially explosive atmospheres eg EN60079 14 EN60079 17 This instruction sheet describes installation which conforms with BS EN60079 14 BS EN60079 17 Electrical Installation in Hazardous Areas When designing systems...

Страница 4: ...r body direct to the input screw terminals The screw terminals have been designed to allow all connection wires to enter from an inner or an outer direction Care must be taken when locating the transmitter to ensure the ambient temperature remains within the specified operating range Fig 3 All Dimensions in mm 3 2 ELECTRICAL Connections to the transmitter are made to the screw terminals provided o...

Страница 5: ...ators Temperature Probes Trip Amplifiers Signal Conditioners And many other products For further information on all products Status Instruments Ltd Status Business Park Tewkesbury Glos GL20 8FD Tel 44 0 1684 296818 Fax 44 0 1684 293746 Email sales status co uk Web www status co uk Page 8 2 1 1 Pt100 4 5 6 HART Temp Tx 4 to 20 mA T C 2 3 Power Supply Load 3 4 5 6 Pt100 3 3 3 4 6 4 4 10 to 40 VDC mV...