You must obtain a Return Material Authorization (RMA) number

from Xantrex before returning a product directly to Xantrex.  Do not

return a product to Xantrex without first obtaining an RMA number.

When you contact Xantrex to obtain service, be prepared to supply

the serial number of your product and its date of purchase as well as

information about the installation or use of the unit.
If you are returning a product from the USA or Canada, follow this

procedure:

1. Obtain an RMA number and a shipping address from Xantrex.

Product(s) returned without an RMA number or shipped

collect, will be refused.

2. Package the unit safely, preferably using the original packing

materials.  Include the RMA number, a copy of your dated

proof of purchase, a return address where the repaired unit

can be shipped, a contact telephone number, and a brief

description of the problem.

3. Ship the unit to the address provided in Step 1, freight

prepaid.  Obtaining proof of delivery is recommended.

The Performance Guarantee. 

Xantrex guarantees the

PORTAWATTZ 400 will run any 27 inch television plus a VCR, or

Xantrex will replace your unit with another inverter (selected at

Xantrex’s option) that will run your particular television model. This

performance guarantee is offered because we are confident you will

find the PORTAWATTZ 400’s performance superior to any other

brand with similar power ratings.

Conditions that apply to the Performance Guarantee. 

This

guarantee is valid only if your PORTAWATTZ 400 is installed to a

properly functioning power source according to guidelines in this

manual.  For certain televsion models it may be necessary to wire the

inverter directly to a 12-Volt battery source.  Your PORTAWATTZ

400 must be within the warranty period and all conditions that apply

to the Warranty also apply to the Performance Guarantee.  In

addition, the television and VCR must be an AC powered consumer

model designed for use in the USA or Canada and in proper working

condition.  The television must have a screen size of 27 inches or less

as specified by the television’s manufacturer and may not be a flat

screen type.  The television and VCR may not be altered in any way

or used in an unsuitable environment..

Содержание Portawattz 400

Страница 1: ...Tel 604 420 1585 toll free 1 800 670 0707 Fax 604 420 1591 toll free 1 800 994 7828 Email support portawattz xantrex com Web www xantrex com 445 0111 01 01 Printed in China...

Страница 2: ...gistered trademarks of Xantrex International Xantrex is a registered trademark of Xantrex Technology Inc 2001 Xantrex International All rights reserved Notice of Copyright PORTAWATTZ 400 Installation...

Страница 3: ...Guidelines 7 5 1 Selecting a Suitable Location 7 5 2 Using the DC Cable Plug 7 5 3 Using the DC Cable Clips 8 5 4 Permanent Installation 9 6 Battery Selection and Charging 13 6 1 Battery Sizing Genera...

Страница 4: ...1 Indicators and Controls 20 8 2 Inverter Operation 20 9 Troubleshooting 22 10 Limited Warranty and Performance Guarantee USA and Canada Only 24 11 Service Out of Warranty 27 12 Specifications 28 13...

Страница 5: ...ducts such as TVs computers compact fluorescent lights small power tools 3 5 Amps or less and many more The PORTAWATTZ 400 employs reliable solid state power electronics for years of safe trouble free...

Страница 6: ...water rain snow or spray Do not under any circumstances connect the PORTAWATTZ 400 s AC receptacles to utility power AC distribution wiring WARNING Heated surface The PORTAWATTZ 400 s housing may beco...

Страница 7: ...0 to temperatures exceeding 104 F 40 C CAUTION Do not use the PORTAWATTZ 400 with the following equipment Small battery operated products such as rechargeable flashlights some rechargeable shavers and...

Страница 8: ...e intended to provide a brief overview of the PORTAWATTZ 400 s key features For complete information about the PORTAWATTZ 400 it is important to read this manual fully Figure 1 below shows the PORTAWA...

Страница 9: ...s or less see Section 5 2 To supply power to the AC outlets turn the ON OFF Switch ON The green POWER light indicates AC power is available 3 Plug the AC products you wish to operate into the AC outle...

Страница 10: ...d into a highly advanced circuit design to provide outstanding high surge capability 4 3 Safety Features These advanced safety features are built into the PORTAWATTZ 400 Electronic overload protection...

Страница 11: ...o void your warranty Relatively close to the battery source when installed permanently This will minimize the cable length from the battery to the inverter It is better to run an extension cord from t...

Страница 12: ...Cable Clips By directly connecting the PORTAWATTZ 400 to a 12 Volt battery with the DC Cable Clips you can operate products with power requirements up to 400 Watts continuous If you want to permanent...

Страница 13: ...cable or when the battery to inverter run is greater than 12 ft may result in excessive voltage drop between the battery and PORTAWATTZ 400 and cause the inverter to prematurely shut down As a genera...

Страница 14: ...unsure how to make a safe connection contact Xantrex Customer Service for assistance Figure 2 illustrates a basic connection to a 12 Volt battery 1 Turn the ON OFF Switch on the PORTAWATTZ 400 to OFF...

Страница 15: ...use to the positive battery post and fasten securely If you are using a battery selector switch connect the positive cable from the PORTAWATTZ 400 to the positive terminal and fasten securely 7 If a c...

Страница 16: ...e permanent connectors regularly and prevent corrosion by using an insulating spray coating WARNING Do not connect the PORTAWATTZ 400 to a battery if there are flammable fumes or liquids present Explo...

Страница 17: ...s are designed for repeated cycles of full discharge and recharge and are often used in RVs boats and golf carts Select this type of battery when most of your applications require higher power more th...

Страница 18: ...t for less or more time limited approximately by the 100Ah figure e g 50A for 2 hours or 200A for 1 2 hour but usually the capacity figure given is only accurate at the specified rate 20 hours 6 2 Est...

Страница 19: ...servative and resist the temptation to skip the last step of this calculation multiply by 2 More capacity is better because you gain more reserve capacity and therefore can better handle large loads a...

Страница 20: ...e air temperature drops to 0 F 20 C the actual amp hour capacity will be about one half of the battery s rated capacity Do not leave batteries in a discharged state for more than two days Batteries le...

Страница 21: ...ies since these are not intended for continuous use Your battery may also be recharged from a solar panel but make sure it has an appropriate charge controller or that a charge controller is added Veh...

Страница 22: ...an 400 Watts may exceed its surge capabilities and trigger its safety overload shutdown feature If this problem occurs when attempting to operate several AC products at the same time try first switchi...

Страница 23: ...uld minimize or eliminate the problem Use an extension cord to increase the distance between the PORTAWATTZ 400 and the TV antenna and cables Adjust the orientation of the PORTAWATTZ 400 television an...

Страница 24: ...WER light activate the cooling fan and deliver AC power to the two outlets 2 As the battery charge is used up battery voltage begins to fall When the PORTAWATTZ 400 senses that the voltage at its DC i...

Страница 25: ...connected AC loads 7 Should a defective battery charging system cause the battery voltage to rise to dangerously high levels the PORTAWATTZ 400 automatically shuts down CAUTION Although the PORTAWATTZ...

Страница 26: ...400Watts or 120 Volts 3 5 Amps Product exceeds inverter s surge capability Use a product with starting surge power within the PORTAWATTZ 400 s capability Recharge battery Switch PORTAWATTZ 400 OFF an...

Страница 27: ...r accurate measurement Recharge battery Possible Cause AC product power consumption is higher than rated Battery is old or defective Battery is not being properly charged Power dissipation in DC cable...

Страница 28: ...tal special or consequential or economic loss even though caused by the negligence or fault of Xantrex Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damage...

Страница 29: ...ntrex guarantees the PORTAWATTZ 400 will run any 27 inch television plus a VCR or Xantrex will replace your unit with another inverter selected at Xantrex s option that will run your particular televi...

Страница 30: ...which it did not work In most cases you will receive a Return Authorization Number and return shipping instructions from Customer Service which allows you to return your PORTAWATTZ 400 for an upgraded...

Страница 31: ...ut of warranty service contact Xantrex customer service for a Return Material Authorization RMA number and follow the other steps outlined in the section Service During Warranty above Options for paym...

Страница 32: ...eform modified sine wave Battery drain with no AC load at 12V input 0 25 Amps Efficiency maximum 90 Ambient operating temperature range 32 F 104 F 0 C 40 C Low battery alarm trigger point nominal 10 7...

Страница 33: ...and even many smaller microwave ovens PORTAWATTZ 1750 Inverter A 1750 Watt inverter designed for installation in a boat vehicle or remote home for operating power tools kitchen appliances and a wide...

Страница 34: ...the PROsine line of high performance true sine wave inverters and PROsine inverter chargers and the TRUECHARGE line of smart battery chargers Contact your Xantrex retailer for more information or vis...

Страница 35: ...31...

Страница 36: ...Tel 604 420 1585 toll free 1 800 670 0707 Fax 604 420 1591 toll free 1 800 994 7828 Email support portawattz xantrex com Web www xantrex com 445 0111 01 01 Printed in China...