21
your Portawattz out of sight and turn your Portawattz ON or
OFF from a conveniently located panel. The remote switch
has a push-button and indicator light showing that the inverter
is ON or OFF (see your Statpower dealer for more details on
the Portawattz Remote ON/OFF switch).
6.1.3. Battery Voltage Indicator
The battery voltage indicator displays the voltage at the input
terminals of the Portawattz 3000. At low input currents, this
voltage is very close to the battery voltage. At high input
currents, this voltage will be lower than the battery voltage
because of the voltage drop across the cables and connections.
Ideally, the voltage should remain in the green area of the
indicator. If the voltage goes into the red area at the top or
bottom of the indicator, the Portawattz 3000 may shut down.
6.1.4. Battery Current Indicator
The battery current indicator displays the current drawn from
the battery by the Portawattz 3000. It will not indicate current
drawn by other loads also connected to the battery.
For long term operation, the current should remain in the green
area of the indicator. Short term operation is possible with
current in the yellow area. If the current rises to the red area,
the Portawattz will reduce its output voltage to protect itself.
6.1.5. OVERTEMP Indicator
The OVERTEMP indicator illuminates and the alarm indicator
sounds when the Portawattz 3000 has overheated and shut
itself down. The Portawattz may overheat because it has been
operated at power levels above its 2500 watt continuous output
rating, or because it has been installed in a location which does
not allow it to dissipate heat properly. The Portawattz 3000 will
restart automatically once it has cooled.
6.1.6 OVERLOAD Indicator
The OVERLOAD indicator illuminates when the Portawattz 3000
has shut itself down because of a severe overload. To Restart
the Portawattz 3000 switch the ON/OFF switch to OFF, correct
the fault condition (disconnect the load), and then switch the
ON/OFF switch back to ON.