WATER HEATER CONTROL BOARD TROUBLESHOOTING AND DIAGNOSTIC LED
INTERPRETATION
Conditions:
●
Power On
●
Red, heater control “Call for Heat” LED – on
●
Red, ignition control board diagnostic LED – Flashing
●
Note LED Flash Code before resetting heater.
n
o
it
a
c
i
d
n
I
s
u
t
a
t
S
D
E
L
1 Flash
System is in lock out.
2 Flashes
Draft proving (pressure) switch failed to open within 5 seconds at the end of the last
cycle.
3 Flashes
Draft proving (pressure) switch failed to close ( -2.1 inches of water column pressure)
within 5 seconds after the inducer was started.
The low gas pressure switch )closes
at 5.2" ± .04" w. c.) may have remained open (Nat Gas only.)
4 Flashes
Open on high temperature limit switch (ECO).
5 Flashes
Not Used
6 Flashes
115-volt supply power connection is indicating reversed polarity.
7 Flashes
Flame sensor reads a low flame signal for more than 4.25 sec.
8 Flashes
No ignition sensed.
Continuous Flash
Continuous flame sensed for more than 5 seconds without gas valve being energized.
Continuous ON
Internal control board failure.
*Control system self adjusts to use a minimum voltage for ignition. Lower voltage results in lower IGNITOR
temperature which results in longer IGNITOR life. IGNITOR voltage may vary from Nominal 80 VAC.