FOREWORD

Thank you for buying this energy efficient water heater from
State.  We appreciate your confidence in our products.  Detailed
installation diagrams are in this manual.  These diagrams will
serve to provide the installer with a reference for the materials
and method of piping suggested.  IT IS NECESSARY THAT ALL
WATER PIPING AND THE ELECTRICAL WIRING BE INSTALLED
AND CONNECTED AS SHOWN IN THE DIAGRAMS.

In addition to these instructions, the water heater must be installed
in accordance with local codes and the authority having
jurisdiction.

GENERAL SAFETY INSTRUCTIONS

BE SURE TO TURN OFF POWER WHEN WORKING ON OR
NEAR THE ELECTRICAL SYSTEM OF THE HEATER.  NEVER
TOUCH ELECTRICAL COMPONENTS WITH WET HANDS OR
WHEN STANDING IN WATER.  WHEN REPLACING FUSES
ALWAYS USE THE CORRECT SIZE FOR THE CIRCUIT.

The principal components of the heater are identified on page
6.  The model and rating plate on page 5 interprets certain
markings into useful information.  Both of these references
should be used to identify the heater, its components and optional
equipment.

  

 WARNING

FOR CALIFORNIA INSTALLATION THIS WATER HEATER MUST
BE BRACED, ANCHORED, OR STRAPPED TO AVOID FALLING
OR MOVING DURING AN EARTHQUAKE. SEE INSTRUCTIONS
FOR CORRECT INSTALLATION AND PROCEDURES.
INSTRUCTIONS MAY BE OBTAINED FROM YOUR LOCAL
DEALER, WHOLESALER, PUBLIC UTILITIES OR
CALIFORNIA’S OFFICE OF STATE ARCHITECT, 400 P STREET,
SACRAMENTO, CALIFORNIA 95814.

INSULATION BLANKETS

Insulation blankets available to the general public for external
use on electric water heaters are not approved for use on your
State water heater.  The purpose of an insulation blanket is to
reduce the standby heat loss encountered with storage tank water
heaters.  Your State water heater meets or exceeds the National
Appliance Energy Act standards with respect to insulation and
standby loss requirements, making an insulation blanket
unnecessary.

  

WARNING

Should you choose to apply an insulation blanket to this heater,
you should follow these instructions (See page 5 for identification
of components mentioned below).  Failure to follow these
instructions can result in fire, serious personal injury or death.

• Do not cover the temperature & pressure relief valve.
• Do not cover the instruction manual.  Keep it on the side of

the water heater or nearby for future reference.

• Do obtain new labels from State Water Heaters for placement

on the blanket directly over the existing labels.

EXTENDED NON-USE PERIODS

 

 

CAUTION

HYDROGEN GAS CAN BE PRODUCED IN A HOT WATER
SYSTEM SERVED BY THIS HEATER THAT HAS NOT BEEN USED
FOR A LONG PERIOD OF TIME (GENERALLY TWO WEEKS OR
MORE).  HYDROGEN GAS IS EXTREMELY FLAMMABLE. 

 To

reduce the risk of injury under these conditions, it is recommended
that the hot water faucet be opened for several minutes at a  nearby
kitchen sink before using any electrical appliance connected to the
hot water system.  If hydrogen is present, there will probably be an
unusual sound such as air escaping through the pipe as the water
begins to flow.  

THERE SHOULD BE NO SMOKING OR OPEN

FLAME NEAR THE FAUCET AT THE TIME IT IS OPENED.

  

CAUTION

AN ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK
OF ELECTRIC SHOCK OR POSSIBLE ELECTROCUTION.  THE
GROUND SCREW AT THE JUNCTION BOX IS FOR BONDING
THE HEATER TO A GROUNDED SERVICE ENTRANCE
CONDUCTOR, A GROUNDED SERVICE ENTRANCE RACEWAY,
OR AN EARTH GROUNDING ELECTRODE CONDUCTOR.

  

WARNING

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT
IN SERIOUS PERSONAL INJURY OR DEATH.

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER
REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED
TRADESMAN IN THE FIELD INVOLVED. PLUMBING AND
ELECTRICAL WORK ARE REQUIRED.

GENERAL

The installation must conform to these instructions, the local code
authority having jurisdiction, and the requirements of the power
company.  In the absence of code requirements follow the current
edition of  NFPA-70, The National Electrical Code which may be
ordered from: National Fire Protection Association,
1 Batterymarch Park, Quincy, MA 02269.

LOCATION

The water heater should be located as close as possible to/or
centralized to the water piping system. The water heater should
be located in an area not subject to freezing temperatures.

The heater should be located in an area where leakage of the
tank or connections will not result in damage to the area adjacent
to the heater or to lower floors of the structure.

When such locations cannot be avoided, a suitable drain pan
should be installed under the heater.

Such pans should be at least two inches deep, have a minimum
length and width of at least two inches greater than the diameter
of the heater and should be piped to an adequate drain.

Drain pans suitable for these heaters are available from your
distributor or State Water Heaters, 500 Tennessee Waltz Parkway,
Ashland City, TN 37015.

Water heater life depends upon water quality, water pressure and
the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage may
result in property damage, even with the use of a drain pan piped
to a drain. However, unanticipated damage can be reduced or
prevented by a leak detector or water shut-off device used in
conjunction with a piped drain pan. These devices are available
from some plumbing supply wholesalers and retailers, and detect
and react to leakage in various ways:

• Sensors mounted in the drain pan that trigger an alarm or turn

off the incoming water to the water heater when leakage is
detected.

Содержание PCE 120 20RTA

Страница 1: ...enance Leakage Checkpoints Limited Warranty 500 Tennessee Waltz Parkway Ashland City TN 37015 www statewaterheaters com CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THIS APPLIANCE PLACE THESE INSTRUCTIONS ADJACENT TO HEATER AND NOTIFY OWNER TO KEEP FOR FUTURE REFERENCE ...

Страница 2: ... 75 68 56 51 45 41 38 34 32 10 LPH 426 384 284 256 213 192 170 153 142 128 122 6000 6000 GPH 135 122 90 81 68 61 54 49 45 41 39 12 LPH 511 460 341 307 256 230 205 184 170 153 146 Recovery capacities at 100 F rise equal for non simultaneous element operation 4 1 gal x KW of one element for simultaneous element operation 4 1 gal x 2 3 KW of both elements For other rises multiply element KW as previo...

Страница 3: ...E To reduce the risk of injury under these conditions it is recommended that the hot water faucet be opened for several minutes at a nearby kitchen sink before using any electrical appliance connected to the hot water system If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow THERE SHOULD BE NO SMOKING OR OPEN FLAME NEAR ...

Страница 4: ...e portions of the wire size tables from the Code are reproduced here The branch circuit should be sized at 125 percent of the heater rating and further increase wire size as necessary to compensate for voltage drop in long runs CALCULATING AMPERAGE OVERCURRENT PROTECTION The heaters come from the factory in two configurations 1 Two wire C 2 circuit for single element heater equipped with a high li...

Страница 5: ...167 F TYPES TYPES RUW RH RHW RUH 12 2 12 2 THW T TW THWN XHHW UF USE 12 15 15 10 25 25 8 30 40 6 40 50 4 55 65 3 65 75 2 75 90 1 85 100 FACTORY WIRED FIELD WIRING WHITE FOR 120V AND 277V Portion of Table 310 18 follows Allowable Ampacities of Insulated Aluminum and Copper Clad Aluminum Conductors Not more than three conductors in Raceway or Cable or Direct Burial Based on Ambient Temperature of 30...

Страница 6: ...ICES FOR HOT WATER SUPPLY SYSTEMS ANSI Z21 22 This valve must be marked with a maximum set pressure not to exceed the marked maximum working pressure of the water heater Install the valve into an opening provided and marked for this purpose in the water heater and orient it or provide tubing so INSTALL VACUUM RELIEF IN COLD WATER INLET LINE AS REQUIRED BY LOCAL CODES INSTALL SUITABLE DRAIN PANS UN...

Страница 7: ...PPER THERMOSTAT BEHIND JUNCTION BOX DOOR ADJUSTABLE LOWER SINGLE THERMOSTAT Figure 3 shows the approximate time to burn relationship for normal adult skin The thermostats on your water heater have a linear relationship between degrees of angular rotation and the corresponding change in temperature Thus rotating the temperature adjustment indicator 30 angular degrees will result in a 10 degree Fahr...

Страница 8: ... ensure that it is in operating condition Lift the lever on the valve several times until the valve seats properly and operates freely CAUTION THE WATER PASSING OUT OF THE VALVE DURING THIS CHECKING OPERATION MAY BE EXTREMELY HOT It is recommended that the drain valve on this unit be opened once a month and 1 to 2 gallons of water be allowed to drain out This will help to prevent sediment buildup ...

Страница 9: ...lief valve leakage It is often caused by a closed system A check valve in the inlet system will not permit the expanded hot water volume to equalize pressure with the main A relief valve must release this water or the water heater or plumbing system will be damaged Damage to the water heater caused by a closed system is not covered by the limited warranty The only solution is to install a thermal ...

Страница 10: ...electricity and drain tank to perform procedure Water leaks at the elements may be due to 1 Defective element which leaks at terminals or thru flange Replace element 2 Loose element gasket leak a Screw in type tighten with 1 1 2 socket wrench or Part Number 23985 wrench If leak continues remove element discard gasket and clean thread areas Apply nonhardeningPermatex Number 2 to thread areas instal...

Страница 11: ...pped at prevailing prices and you will be billed accordingly The model number of your Water Heater will be found on the rating plated located above the lower access panel Be sure to provide all pertinent facts when you call or visit WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION MODEL NUMBER VOLTAGE AND ELEMENT WATTAGE SERIAL NUMBER PART DESCRIPTION PCE 6 thru PCE 20 refer to Rep...

Страница 12: ...734 182734 182734 182734 10 Personnel Protector 9003899 9003899 9003899 9003899 11 Pipe Nipple 194130 194130 3 194130 3 194130 3 12 Plate Knockout 43293 1 43293 1 43293 1 43293 1 PLUG 13 Cap 42306 1 42306 1 42306 1 42306 1 14 Pipe 9001437 9001437 9001437 9001437 15 16 Thermostat with High Limit Switch 9003945 9003945 9003945 9003945 17 Bracket Thermostat 9003898 9003898 9003898 9003898 18 Valve Re...

Страница 13: ... 3020LSA thru PCE 5020LSA Refer to Repair Parts Table on Pages 14 15 for dual elements electric units PCE 3020RTA thru PCE 12020 RTA Refer to Repair Parts Table on Pages 14 15 for dual elements electric units ...

Страница 14: ...n Box Assembly 195171 195171 195171 195171 16 Manual 195202 002 195202 002 195202 002 195202 002 Not Illustrated Standard Hardware Items May Be Purchased Locally Underlined Parts Are Recommended For Emergency Replacement K W ELEMENT 120V 208V 240V 277V 480V WATTAGE PART NO PART NO PART NO PART NO PART NO 1 0 1000W 9002863 9000143 1 5 1500W 9002963 9000145 9002864 9001225 2 0 2000W 9003947 9002858 ...

Страница 15: ...2 195202 002 Not Illustrated Standard Hardware Items May Be Purchased Locally Underlined Parts Are Recommended For Emergency Replacement PCE 40 20RTA PCE 52 20RTA PCE 66 20RTA PCE 82 20RTA PCE 120 20RTA Series 110 Series 110 Series 110 Series 110 Series 110 K W ELEMENT 120V 208V 240V 277V 480V WATTAGE PART NO PART NO PART NO PART NO PART NO 1 5 1500W 9004279 9004283 9004290 2 0 2000W 9004280 90042...

Страница 16: ...16 500 Tennessee Waltz Parkway Ashland City TN 37015 Phone 800 821 2017 Fax 800 644 9306 www statewaterheaters com ...

Отзывы: