WATER HEATER INSTALLATION
T&P VALVE DISCHARGE PIPE
Explosion Hazard
Temperature-Pressure Relief Valve
must comply with ANSI Z21.22-
CSA 4.4 and ASME code.
Properly sized temperature-
pressure relief valve must be
installed in opening provided.
Can result in overheating and
excessive tank pressure.
Can cause serious injury or death.
7KLVZDWHUKHDWHULVSURYLGHGZLWKDSURSHUO\UDWHGVL]HGDQG
FHUWL¿HG FRPELQDWLRQ WHPSHUDWXUH SUHVVXUH 7 3 UHOLHI
YDOYHE\WKHPDQXIDFWXUHU6HH7HPSHUDWXUH3UHVVXUH5HOLHI
9DOYH RQ SDJHV IRU LQIRUPDWLRQ RQ UHSODFHPHQW DQG
RWKHUUHTXLUHPHQWV
Water Damage Hazard
Temperature-Pressure Relief Valve discharge
pipe must terminate at adequate drain.
CAUTION
,QVWDOODGLVFKDUJHSLSHEHWZHHQWKH7 3YDOYHGLVFKDUJHRSHQLQJ
DQG D VXLWDEOH ÀRRU GUDLQ 'R QRW FRQQHFW GLVFKDUJH SLSLQJ
GLUHFWO\ WR WKH GUDLQ XQOHVV D ´ FP DLU JDS LV SURYLGHG
7RSUHYHQWERGLO\LQMXU\KD]DUGWROLIHRUSURSHUW\GDPDJHWKH
UHOLHI YDOYH PXVW EH DOORZHG WR GLVFKDUJH ZDWHU LQ DGHTXDWH
TXDQWLWLHVVKRXOGFLUFXPVWDQFHVGHPDQG,IWKHGLVFKDUJHSLSHLV
QRWFRQQHFWHGWRDGUDLQRURWKHUVXLWDEOHPHDQVWKHZDWHUÀRZ
PD\FDXVHSURSHUW\GDPDJH
T&P VALVE DISCHARGE PIPE REQUIREMENTS:
6KDOOQRWEHVPDOOHULQVL]HWKDQWKHRXWOHWSLSHVL]HRIWKH
YDOYHRUKDYHDQ\UHGXFLQJFRXSOLQJVRURWKHUUHVWULFWLRQV
6KDOOQRWEHSOXJJHGRUEORFNHG
6KDOOQRWEHH[SRVHGWRIUHH]LQJWHPSHUDWXUHV
6KDOOEHRIPDWHULDOOLVWHGIRUKRWZDWHUGLVWULEXWLRQ
6KDOOEHLQVWDOOHGVRDVWRDOORZFRPSOHWHGUDLQDJHRIERWK
7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHDQGWKHGLVFKDUJHSLSH
0XVWWHUPLQDWHDPD[LPXPRIVL[LQFKHVDERYHDÀRRU
GUDLQRUH[WHUQDOWRWKHEXLOGLQJ,QFROGFOLPDWHVLWLV
UHFRPPHQGHGWKDWWKHGLVFKDUJHSLSHEHWHUPLQDWHGDWDQ
DGHTXDWHGUDLQLQVLGHWKHEXLOGLQJ
6KDOOQRWKDYHDQ\YDOYHRURWKHUREVWUXFWLRQEHWZHHQWKH
UHOLHIYDOYHDQGWKHGUDLQ
WATER LINE CONNECTIONS
7KHZDWHUSLSLQJLQVWDOODWLRQPXVWFRQIRUPWRWKHVHLQVWUXFWLRQV
DQGWRDOOORFDOFRGHDXWKRULW\KDYLQJMXULVGLFWLRQ*RRGSUDFWLFH
UHTXLUHVWKDWDOOKHDY\SLSLQJEHVXSSRUWHG
5HDG DQG REVHUYH DOO UHTXLUHPHQWV LQ WKH IROORZLQJ VHFWLRQV
EHIRUHLQVWDOODWLRQRIWKHZDWHUSLSLQJEHJLQV
:DWHU7HPSHUDWXUH&RQWURODQG0L[LQJ9DOYHVRQSDJH
'LVKZDVKLQJ0DFKLQHVRQSDJH
7HPSHUDWXUH3UHVVXUH5HOLHI9DOYHRQSDJH
&ORVHG6\VWHPVDQG7KHUPDO([SDQVLRQRQSDJH
)RU PXOWLSOH ZDWHU KHDWHU LQVWDOODWLRQV VHH :DWHU 3LSLQJ
'LDJUDPVEHJLQQLQJRQSDJH
WATER (POTABLE) HEATING AND SPACE HEATING
$OO SLSLQJ FRPSRQHQWV FRQQHFWHG WR WKLV XQLW IRU VSDFH
KHDWLQJDSSOLFDWLRQVVKDOOEHVXLWDEOHIRUXVHZLWKSRWDEOH
ZDWHU
7R[LFFKHPLFDOVVXFKDVWKRVHXVHGIRUERLOHUWUHDWPHQW
VKDOO1(9(5EHLQWURGXFHGLQWRWKLVV\VWHP
7KLV XQLW PD\ 1(9(5 EH FRQQHFWHG WR DQ\ H[LVWLQJ
KHDWLQJ V\VWHP RU FRPSRQHQWV SUHYLRXVO\ XVHG ZLWK D
QRQSRWDEOHZDWHUKHDWLQJDSSOLDQFH
:KHQ WKH V\VWHP UHTXLUHV ZDWHU IRU VSDFH KHDWLQJ DW
WHPSHUDWXUHV KLJKHU WKDQ UHTXLUHG IRU GRPHVWLF ZDWHU
SXUSRVHV D WHPSHULQJ YDOYH PXVW EH LQVWDOOHG 3OHDVH
UHIHUWRLQVWDOODWLRQGLDJUDPVEHJLQQLQJRQSDJHRIWKLV
PDQXDOIRUVXJJHVWHGSLSLQJDUUDQJHPHQWV
7KHVH ZDWHU KHDWHUV FDQQRW EH XVHG LQ VSDFH KHDWLQJ
DSSOLFDWLRQVRQO\
THERMOMETERS (NOT SUPPLIED)
7KHUPRPHWHUVVKRXOGEHREWDLQHGDQG¿HOGLQVWDOOHGDVVKRZQ
LQWKHLQVWDOODWLRQGLDJUDPV
7KHUPRPHWHUV DUH LQVWDOOHG LQ WKH V\VWHP DV D PHDQV RI
GHWHFWLQJWKHWHPSHUDWXUHRIWKHRXWOHWZDWHUVXSSO\
WATER PIPING DIAGRAMS
7KLVPDQXDOSURYLGHVGHWDLOHGZDWHUSLSLQJGLDJUDPVIRUW\SLFDO
PHWKRGVRIDSSOLFDWLRQIRUWKHZDWHUKHDWHUVVHH:DWHU3LSLQJ
'LDJUDPVEHJLQQLQJRQSDJH
7KHZDWHUKHDWHUPD\EHLQVWDOOHGE\LWVHOIRUZLWKDVHSDUDWH
VWRUDJH WDQN :KHQ XVHG ZLWK D VHSDUDWH VWRUDJH WDQN WKH
FLUFXODWLRQPD\EHHLWKHUE\JUDYLW\RUE\PHDQVRIFLUFXODWLQJ
SXPS$GMXVWÀRZE\WKURWWOLQJDIXOOSRUWEDOOYDOYHLQVWDOOHGLQWKH
FLUFXODWLQJOLQHRQWKHRXWOHWVLGHRIWKHSXPS1HYHUWKURWWOHÀRZ
RQWKHVXFWLRQVLGHRIDSXPS6HHWKH:DWHU3LSLQJ'LDJUDPV
EHJLQQLQJRQSDJH
&DOOWKHWROOIUHHWHFKQLFDOVXSSRUWSKRQHQXPEHUOLVWHGRQWKH
EDFNFRYHURIWKLVPDQXDOIRUIXUWKHUDVVLVWDQFHLQVL]LQJD7 3
YDOYHIRUUHPRWHVWRUDJHWDQNV