11
DO NOT
FRYHUWKHLQVWUXFWLRQPDQXDO.HHSLWRQWKHVLGHRI
WKHZDWHUKHDWHURUQHDUE\IRUIXWXUHUHIHUHQFH
DO
REWDLQ QHZ ZDUQLQJ DQG LQVWUXFWLRQ ODEHOV IURP WKH
PDQXIDFWXUHUIRUSODFHPHQWRQWKHEODQNHWGLUHFWO\RYHUWKH
H[LVWLQJODEHOV
DO
LQVSHFWWKHLQVXODWLRQEODQNHWIUHTXHQWO\WRPDNHFHUWDLQLW
GRHVQRWVDJWKHUHE\REVWUXFWLQJFRPEXVWLRQDLUÀRZ
HARD
WATER
:KHUH KDUG ZDWHU FRQGLWLRQV H[LVW ZDWHU VRIWHQLQJ RU WKH
WKUHVKROG W\SH RI ZDWHU WUHDWPHQW LV UHFRPPHQGHG 7KLV ZLOO
SURWHFWWKHGLVKZDVKHUVFRIIHHXUQVZDWHUKHDWHUVZDWHUSLSLQJ
DQGRWKHUHTXLSPHQW
6HH WKH 0DLQWHQDQFH 6HFWLRQ LQ WKLV PDQXDO IRU VHGLPHQW DQG
OLPHVFDOHUHPRYDOSURFHGXUHV
CIRCULATION
PUMPS
$FLUFXODWLQJSXPSLVXVHGZKHQDV\VWHPUHTXLUHVDFLUFXODWLQJ
ORRSRUWKHUHLVDVWRUDJHWDQNXVHGLQFRQMXQFWLRQZLWKWKHZDWHU
KHDWHU6HH:DWHU3LSLQJ'LDJUDPVLQWKLVPDQXDOIRULQVWDOODWLRQ
ORFDWLRQRIFLUFXODWLQJSXPSV
6HH WKH &LUFXODWLRQ 3XPS :LULQJ 'LDJUDPV LQ WKLV PDQXDO IRU
HOHFWULFDO KRRNXS LQIRUPDWLRQ ,QVWDOO LQ DFFRUGDQFH ZLWK WKH
FXUUHQWHGLWLRQRIWKH1DWLRQDO(OHFWULFDO&RGH1)3$RUWKH
&DQDGLDQ(OHFWULFDO&RGH&6$&
$OOEURQ]H FLUFXODWLQJ SXPSV DUH UHFRPPHQGHG IRU XVHG ZLWK
FRPPHUFLDOZDWHUKHDWHUV
6RPHFLUFXODWLQJSXPSVDUHPDQXIDFWXUHGZLWKVHDOHGEHDULQJV
DQG GR QRW UHTXLUH IXUWKHU OXEULFDWLRQ 6RPH FLUFXODWLQJ SXPSV
PXVW EH SHULRGLFDOO\ RLOHG 5HIHU WR WKH SXPS PDQXIDFWXUHU¶V
LQVWUXFWLRQVIRUOXEULFDWLRQUHTXLUHPHQWV
CIRCULATING PUMP WIRING DIAGRAM
STORAGE TANK OR BUILDING RECIRCULATION
FIELD SUPPLIED TEMPERATURE CONTROL
INSTALLED IN THE STORAGE TANK
OR CIRCULATING LOOP RETURN LINE
CIRC
PUMP
MOTOR
L1 HOT
L2 NEUTRAL
120 VAC
POWER
NOTE:
USE SEPARATE 120 VAC POWER
SUPPLY FOR PUMP CIRCUIT. DO NOT
SHARE POWER WITH WATER HEATER AS THIS
MAY CAUSE ELECTRICAL LINE NOISE AND
LEAD TO ERRATIC CONTROL SYSTEM
OPERATION.
FIGURE 8.
CIRCULATING PUMP WIRING DIAGRAM
DISHWASHER LOOP WITH TOGGLE SWITCH
FIELD SUPPLIED TEMPERATURE
CONTROL INSTALLED IN THE
CIRCULATING LOOP RETURN LINE
DISHWASHER
TOGGLE
SWITCH
CIRC
PUMP
MOTOR
L1 HOT
L2 NEUTRAL
120 VAC
POWER
NOTE:
USE SEPARATE 120 VAC POWER
SUPPLY FOR PUMP CIRCUIT. DO NOT SHARE
POWER WITH WATER HEATER AS THIS MAY
CAUSE ELECTRICAL LINE NOISE AND LEAD
TO ERRATIC CONTROL SYSTEM OPERATION.
FIGURE 9.
FIGURE 7.
INSULATION BLANKET
Do not obstruct water heater air intake
with insulating blanket.
Gas and carbon monoxide detectors
are available.
Install water heater in accordance with
the instruction manual.
Breathing carbon monoxide can cause brain damage or
death. Always read and understand instruction manual.
Breathing Hazard - Carbon Monoxide Gas
,QVXODWLRQ EODQNHWV DUH DYDLODEOH WR WKH JHQHUDO SXEOLF IRU
H[WHUQDO XVH RQ JDV ZDWHU KHDWHUV EXW DUH QRW QHFHVVDU\
ZLWK WKHVH SURGXFWV 7KH SXUSRVH RI DQ LQVXODWLRQ EODQNHW
LVWRUHGXFHWKHVWDQGE\KHDWORVVHQFRXQWHUHGZLWKVWRUDJH
WDQNKHDWHUV7KHZDWHUKHDWHUVFRYHUHGE\WKLVPDQXDOPHHW
RU H[FHHG WKH (QHUJ\ 3ROLF\ $FW VWDQGDUGV ZLWK UHVSHFW WR
LQVXODWLRQ DQG VWDQGE\ KHDW ORVV UHTXLUHPHQWV PDNLQJ DQ
LQVXODWLRQEODQNHWXQQHFHVVDU\
6KRXOG \RX FKRRVH WR DSSO\ DQ LQVXODWLRQ EODQNHW WR WKLV
KHDWHU \RX VKRXOG IROORZ WKHVH LQVWUXFWLRQV 6HH WKH
)HDWXUHV DQG &RPSRQHQWV VHFWLRQ RI WKLV PDQXDO IRU
LGHQWLILFDWLRQ RI FRPSRQHQWV PHQWLRQHG EHORZ )DLOXUH WR
IROORZWKHVHLQVWUXFWLRQVFDQUHVWULFWWKHDLUIORZUHTXLUHGIRU
SURSHUFRPEXVWLRQSRWHQWLDOO\UHVXOWLQJLQILUHDVSK\[LDWLRQ
VHULRXVSHUVRQDOLQMXU\RUGHDWK
DO NOT
DSSO\LQVXODWLRQWRWKHWRSRIWKHZDWHUKHDWHUDVWKLV
ZLOOLQWHUIHUHZLWKVDIHRSHUDWLRQRIWKHGUDIWFRQWURO
DO NOT
FRYHU WKH JDV FRQWURO YDOYH WKHUPRVWDW RU WKH
7HPSHUDWXUH3UHVVXUH5HOLHI9DOYH
DO NOT
DOORZLQVXODWLRQWRFRPHZLWKLQ´FPRIWKHEXUQHUV
WRSUHYHQWEORFNDJHRIFRPEXVWLRQDLUÀRZWRWKHEXUQHUV
Содержание 650A