4. If the heater was installed when incoming water temperatures

were warm, colder incoming temperatures will create the effect
of less hot water.

5. The thermostat water temperature adjusting dial may be set

too low.

6. If you cannot determine the cause of the problems, contact

your dealer.

WATER TEMPERATURE IS TOO HOT

1. The thermostat water temperature adjusting dial may be set

too high.

2. If lowering control setting does not reduce the water

temperature contact your dealer.

GAS SMELL AT THE HEATER

1. Close the main Shut-off valve in the gas supply pipe near the

heater, see fig. 4 on page 8.  The thermostat includes a gas
control (top knob) which can also be closed.

2. Call your gas company.

WATER LEAKAGE IS SUSPECTED

1. Check to see if the heater drain valve is tightly closed.

2. The apparent leakage might be condensation.  In warm or

humid locations, condensation can accumulate and run from
within the heater or its piping.

When a water heater is first installed and filled, the bottom
of the tank might condense water.  The water accumulation,
if excessive, can drip into the floor shield.  Also, during
normal operation there may be occasions when large

quantities of water are drawn, chilling the tank bottom.
This too can result in condensation.

Condensation, appearing in the vent pipe (water dripping
from draft diverter) during heater operation is evidence of
poor vent action.  Possible causes are too long a vent pipe
or improper chimney operation.

3. If the leakage is from the temperature and pressure relief valve

or its discharge pipe, it may represent a normal condition.
However, see RELIEF VALVE section on page 12.  DO NOT
PLUG THE TEMPERATURE AND PRESSURE RELIEF VALVE.
Also, the leakage could be due to unusually high water
pressures or temperatures in the system, or to a faulty relief
valve.  Your dealer or a qualified service technician should be
called to determine the cause of the problem and to correct it.

4. If you cannot identify or correct the source of water leakage:

Close the main Shut-off valve in the gas supply pipe at the

heater.  See fig. 4, page 8.

Close the valve which feeds water to the cold water inlet at

the top of the heater.

Contact your dealer.

WATER HEATER MAKES SOUNDS

1. Occasional excessive condensation, as explained under

LEAKAGE, can cause a sizzling sound as the moisture is
vaporized by the gas flame.  This is a normal sound and may
be disregarded.

2. Sediment and water scale accumulations may cause rumbling

noises.  Contact your dealer for details of flushing the heater.

3. If you cannot identify or remedy the condition, contact your

dealer.

Содержание 196114-000

Страница 1: ...ER Glass Lined Tank Type Water Heater Instruction Manual PART NO 196114 000 INSTALLATION OPERATION SERVICE MAINTENANCE LIMITED WARRANTY PRINTED IN U S A 0903 CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THISAPPLIANCE ...

Страница 2: ...t editions of the National Fuel Gas Code ANSI Z223 1 NFPA 54 in Canada CAN CSA B 149 1 00 Both are available from the Canadian Standards Association 8501 East Pleasant Valley Road Cleveland OH 44131 For Canadian customers 178 Rexdale Blvd Rexdale Toronto Ontario Canada M9W 1R3 The National Fuel Gas Code ANSI Z223 1 NFPA 54 is available from the National Fire Protection Association 1 Batterymarch P...

Страница 3: ...CERTAIN CHEMICAL VAPORS SUCH CORROSION MAY RESULT IN FAILUREAND RISK OFASPHYXIATION Spray can propellants cleaning solvents refrigerator and air conditioning refrigerants swimming pool chemicals calcium and sodium chloride water softener salt waxes and process chemicals are typical compounds which are potentially corrosive Do not store products of this sort near the heater Also air which is brough...

Страница 4: ... THE RISK IF LOCATION IN SUCH AN AREA CANNOT BE AVOIDED DO NOT INSTALL THIS WATER HEATER DIRECTLY ON A CARPETED FLOOR A FIRE HAZARD MAY RESULT Instead the water heater must be placed on a metal or wood panel extending beyond the full width and depth by at least 3 inches 76 mm in any direction If the heater is installed in a carpeted alcove or closet the entire floor shall be covered by the panel A...

Страница 5: ...NSULT CAN CSA B149 1 00 KEEP APPLIANCE AREA CLEAR AND FREE OF COMBUSTIBLE MATERIALS GASOLINEANDOTHERFLAMMABLES VAPORSAND LIQUIDS DO NOT OBSTRUCT THE FLOW OF COMBUSTION OR VENTILATINGAIR WARNING FOR SAFE OPERATION PROVIDE ADEQUATE AIR FOR COMBUSTION AND VENTILATION AN INSUFFICIENT SUPPLY OF AIR WILL CAUSE RECIRCULATION OF COMBUSTION PRODUCTS RESULTING IN AIR CONTAMINATION THAT MAY BE HAZARDOUS TO L...

Страница 6: ...ent connection is not available and the vent pipe from the heater must be connected to a common vent with an oil burning furnace the vent pipe should enter the smaller common vent or chimney at a point above the large vent pipe FIGURE2 DRAFTHOOD The draft hood furnished with this heater must be installed without alteration Provision must be made if it is installed in confined space or a small room...

Страница 7: ...ONS FOR THERMAL EXPANSION OF WATER IN THE HOT WATER SYSTEM MUST BE PROVIDED WARNING TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE TEMPERATURE REGULATION ON PAGE 11 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES SINGLETEMPERATURE Size the main gas line in accordance with Table 1 T...

Страница 8: ...ptable for the purpose in locating the leaks DO NOT USE MATCHES CANDLES FLAME OR OTHER SOURCES OF IGNITION FOR THIS PURPOSE FIGURE4 GASPIPINGANDDIRTLEGINSTALLATION DISCONNECTTHE HEATERAND ITS MANUALGAS Shut off VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURINGANY SUPPLY PRESSURE TESTING EXCEEDING 1 2 PSIG 3 45 Kpa GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER FOR TEST PRESSURES OF ...

Страница 9: ...R STEPS TO BE TAKEN Before lighting the pilot and operating the heater the following conditions must exist Entire system filled with water Air purged from all lines and no leaks gas and water All gas and water lines open PRECAUTIONS DO NOT USE THISAPPLIANCE IF ANY PART HAS BEEN UNDER WATER The heater must be replaced IF THE UNIT IS EXPOSED TO THE FOLLOWING DO NOT OPERATE HEATER UNTILALLCORRECTIVE ...

Страница 10: ...el If you don t smell gas go to next step 6 Remove or open inner door located below gas control unit 7 Find pilot follow metal tube from gas control The pilot is located in front of the burner or on the right hand side of the burner 8 If you don t smell gas turn knob on gas control counter clockwise to PILOT position 9 Push in control knob all the way and hold down Immediately light the pilot with...

Страница 11: ...settings to reduce scald hazards Valves for reducing point of use temperature by mixing cold and hot water are available Also available are inexpensive devices that attach to faucets to limit hot water temperatures Contact a licensed plumber or the local plumbing authority SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAILTO SHUTOFF TURN OFFTHE MAIN MANUALGAS Shut off VALVETO THE APPLIANCE Temperatur...

Страница 12: ... rapid ignition and carryover of flame across entire burner 3 Give reasonably quiet operation during ignition burning and extinction 4 Cause no excessive lifting of flames from burner ports If preceding burner characteristics are not evident check for accumulation of lint or other foreign material that restricts or blocks the air openings to the heater or burner WARNING SOOT BUILD UP INDICATES A P...

Страница 13: ...checked to determine if replacement is necessary Initially the anode rod is approximately 7 8 22mm in diameter with a 1 8 3mm diameter steel core wire running down the center of the anode material THE ANODE SHOULD BE REPLACED when the 1 8 3mm diameter core wire is visible as this means that the anode material has been expended in the control of corrosion NOTE Anode rod inspection may need to be ma...

Страница 14: ...ling the tank bottom This too can result in condensation Condensation appearing in the vent pipe water dripping from draft diverter during heater operation is evidence of poor vent action Possible causes are too long a vent pipe or improper chimney operation 3 If the leakage is from the temperature and pressure relief valve or its discharge pipe it may represent a normal condition However see RELI...

Страница 15: ...15 NOTES ...

Страница 16: ...16 ...

Отзывы: