Compare the actual input rate to that given on the heater’s rating
plate.  In the example, the 65 full input rate should be
65,000 Btuh (19.0 KW) for natural gas.

VENT SYSTEM

Examine the venting system every 6 months for obstructions and/
or deterioration of vent piping.

RELIEF VALVE

At least once a year the temperature and pressure relief valve
should be checked to ensure that it is in operating condition.
(During manual operation of this valve, avoid any contact with hot
water and take preventive steps for water damage).  Lift the lever at
the top of the valve several times until the valve seats properly and
operates freely.

  

WARNING

THE WATER PASSING OUT OF THE VALVE DURING THIS
CHECKING OPERATION MAY BE EXTREMELY HOT.  AVOID
CONTACT AND DISCHARGE SAFELY TO PREVENT WATER
DAMAGE.

If the temperature and pressure relief valve on the heater discharges
periodically or continuously, a problem exists.  This may be due to
unusually high water temperatures or pressures in the system, or
to a faulty relief valve.  Contact your dealer or a qualified service
technician to find the cause of the problem and to correct it.  This
may also be due to thermal expansion in a closed water supply
system.  Contact the water supplier or local plumbing inspector on
how to correct this situation.  

DO NOT PLUG THE TEMPERATURE

AND PRESSURE RELIEF VALVE.

  

WARNING

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO
SHUT OFF, TURN OFF THE MANUAL GAS CONTROL VALVE TO
THE APPLIANCE.

HOT WATER ODOR

On occasion, hot water may develop a strong odor.  If this occurs
drain the heater completely, flush thoroughly, and refill.  If the
problem persists, chlorination of the heater and replacement of
the factory installed magnesium anode with an aluminum anode
may correct the condition.

Occasionally water softener companies recommend removal of
heater anodes for odor reasons.

  

CAUTION

Unauthorized removal of heater anode will void the warranty.
Replace the anode as necessary to maintain corrosion protection.
For further information contact your dealer.

ANODE ROD INSPECTION

The heater tank is equipped with an anode rod to provide corrosion
control.  At least once a year the anode rod should be checked to
determine if replacement is necessary.  Initially the anode rod is
approximately 7/8" (22mm) in diameter with a 1/8" (3mm) diameter
steel core wire running down the center of the anode material.
THE ANODE SHOULD BE REPLACED when the 1/8" (3mm)

diameter core wire is visible as this means that the  anode material
has been expended in the control of corrosion.

NOTE:

 

 Anode rod inspection may need to be made more

frequently in areas subject to acid rain that obtains their water
supply from surface water as the low pH will accelerate anode
activity.

CAUTION:

 

 Close cold water inlet valve serving heater and open

nearby hot water faucet to relieve the pressure in the heater
before attempting to remove anode(s) for inspection.

WINTER PROTECTION

In regions where freezing weather is encountered, all water must
be drained from unit and piping when out of service (water shut
off).  Drain valve must be left open until unit is returned to service.

REPLACEMENT PARTS

Now that you have purchased this water heater, should a need
ever exist for repair parts or service, simply contact the company it
was purchased from or direct from the manufacturer listed on the
rating plate on the water heater.

Be sure to provide all pertinent facts when you call or visit.

Selling prices will be furnished on request or parts will be shipped
at prevailing prices and you will be billed accordingly.

The model number of your gas water heater will be found on the
rating plate located above the gas control valve.

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:

MODEL NUMBER

TYPE GAS (NATURAL OR PROPANE [L.P.])

SERIAL NUMBER

PART DESCRIPTION

CHECKLIST

Before contacting your dealer, check the water heater to see if the
apparent malfunction is caused by some external fault.  Consulting
this checklist may eliminate the need for a repair call and restore
hot water service.

NOT ENOUGH OR NO HOT WATER

1. Check to see if the pilot flame is lit.

To relight the pilot, follow the instructions on the heater or
in this manual.

Check to see if the main gas Shut-off valve in the gas
supply pipe is partially closed or the water temperature
dial is set too low.

2. Look  for leaking or open hot water faucets.  Check for excessive

usage.

3. Your gas company can check the gas input to the heater to see

that it is correct.  An underfired heater will not produce hot
water at its normal recovery rate.

Содержание 196114-000

Страница 1: ...ER Glass Lined Tank Type Water Heater Instruction Manual PART NO 196114 000 INSTALLATION OPERATION SERVICE MAINTENANCE LIMITED WARRANTY PRINTED IN U S A 0903 CAUTION TEXT PRINTED OR OUTLINED IN RED CONTAINS INFORMATION RELATIVE TO YOUR SAFETY PLEASE READ THOROUGHLY BEFORE INSTALLING AND USING THISAPPLIANCE ...

Страница 2: ...t editions of the National Fuel Gas Code ANSI Z223 1 NFPA 54 in Canada CAN CSA B 149 1 00 Both are available from the Canadian Standards Association 8501 East Pleasant Valley Road Cleveland OH 44131 For Canadian customers 178 Rexdale Blvd Rexdale Toronto Ontario Canada M9W 1R3 The National Fuel Gas Code ANSI Z223 1 NFPA 54 is available from the National Fire Protection Association 1 Batterymarch P...

Страница 3: ...CERTAIN CHEMICAL VAPORS SUCH CORROSION MAY RESULT IN FAILUREAND RISK OFASPHYXIATION Spray can propellants cleaning solvents refrigerator and air conditioning refrigerants swimming pool chemicals calcium and sodium chloride water softener salt waxes and process chemicals are typical compounds which are potentially corrosive Do not store products of this sort near the heater Also air which is brough...

Страница 4: ... THE RISK IF LOCATION IN SUCH AN AREA CANNOT BE AVOIDED DO NOT INSTALL THIS WATER HEATER DIRECTLY ON A CARPETED FLOOR A FIRE HAZARD MAY RESULT Instead the water heater must be placed on a metal or wood panel extending beyond the full width and depth by at least 3 inches 76 mm in any direction If the heater is installed in a carpeted alcove or closet the entire floor shall be covered by the panel A...

Страница 5: ...NSULT CAN CSA B149 1 00 KEEP APPLIANCE AREA CLEAR AND FREE OF COMBUSTIBLE MATERIALS GASOLINEANDOTHERFLAMMABLES VAPORSAND LIQUIDS DO NOT OBSTRUCT THE FLOW OF COMBUSTION OR VENTILATINGAIR WARNING FOR SAFE OPERATION PROVIDE ADEQUATE AIR FOR COMBUSTION AND VENTILATION AN INSUFFICIENT SUPPLY OF AIR WILL CAUSE RECIRCULATION OF COMBUSTION PRODUCTS RESULTING IN AIR CONTAMINATION THAT MAY BE HAZARDOUS TO L...

Страница 6: ...ent connection is not available and the vent pipe from the heater must be connected to a common vent with an oil burning furnace the vent pipe should enter the smaller common vent or chimney at a point above the large vent pipe FIGURE2 DRAFTHOOD The draft hood furnished with this heater must be installed without alteration Provision must be made if it is installed in confined space or a small room...

Страница 7: ...ONS FOR THERMAL EXPANSION OF WATER IN THE HOT WATER SYSTEM MUST BE PROVIDED WARNING TEMPERATURE SETTING SHOULD NOT EXCEED SAFE USE TEMPERATURE AT FIXTURES SEE TEMPERATURE REGULATION ON PAGE 11 IF HIGHER PREHEAT TEMPERATURES ARE NECESSARY TO OBTAIN ADEQUATE BOOSTER OUTPUT ADD AN ANTI SCALD VALVE FOR HOT WATER SUPPLIED TO FIXTURES SINGLETEMPERATURE Size the main gas line in accordance with Table 1 T...

Страница 8: ...ptable for the purpose in locating the leaks DO NOT USE MATCHES CANDLES FLAME OR OTHER SOURCES OF IGNITION FOR THIS PURPOSE FIGURE4 GASPIPINGANDDIRTLEGINSTALLATION DISCONNECTTHE HEATERAND ITS MANUALGAS Shut off VALVE FROM THE GAS SUPPLY PIPING SYSTEM DURINGANY SUPPLY PRESSURE TESTING EXCEEDING 1 2 PSIG 3 45 Kpa GAS SUPPLY LINE MUST BE CAPPED WHEN DISCONNECTED FROM THE HEATER FOR TEST PRESSURES OF ...

Страница 9: ...R STEPS TO BE TAKEN Before lighting the pilot and operating the heater the following conditions must exist Entire system filled with water Air purged from all lines and no leaks gas and water All gas and water lines open PRECAUTIONS DO NOT USE THISAPPLIANCE IF ANY PART HAS BEEN UNDER WATER The heater must be replaced IF THE UNIT IS EXPOSED TO THE FOLLOWING DO NOT OPERATE HEATER UNTILALLCORRECTIVE ...

Страница 10: ...el If you don t smell gas go to next step 6 Remove or open inner door located below gas control unit 7 Find pilot follow metal tube from gas control The pilot is located in front of the burner or on the right hand side of the burner 8 If you don t smell gas turn knob on gas control counter clockwise to PILOT position 9 Push in control knob all the way and hold down Immediately light the pilot with...

Страница 11: ...settings to reduce scald hazards Valves for reducing point of use temperature by mixing cold and hot water are available Also available are inexpensive devices that attach to faucets to limit hot water temperatures Contact a licensed plumber or the local plumbing authority SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAILTO SHUTOFF TURN OFFTHE MAIN MANUALGAS Shut off VALVETO THE APPLIANCE Temperatur...

Страница 12: ... rapid ignition and carryover of flame across entire burner 3 Give reasonably quiet operation during ignition burning and extinction 4 Cause no excessive lifting of flames from burner ports If preceding burner characteristics are not evident check for accumulation of lint or other foreign material that restricts or blocks the air openings to the heater or burner WARNING SOOT BUILD UP INDICATES A P...

Страница 13: ...checked to determine if replacement is necessary Initially the anode rod is approximately 7 8 22mm in diameter with a 1 8 3mm diameter steel core wire running down the center of the anode material THE ANODE SHOULD BE REPLACED when the 1 8 3mm diameter core wire is visible as this means that the anode material has been expended in the control of corrosion NOTE Anode rod inspection may need to be ma...

Страница 14: ...ling the tank bottom This too can result in condensation Condensation appearing in the vent pipe water dripping from draft diverter during heater operation is evidence of poor vent action Possible causes are too long a vent pipe or improper chimney operation 3 If the leakage is from the temperature and pressure relief valve or its discharge pipe it may represent a normal condition However see RELI...

Страница 15: ...15 NOTES ...

Страница 16: ...16 ...

Отзывы: