8
Primary BUTTON FUNCTIONS
TOL
Toggles TOL (Tolerances) On & Off.
a. To Toggle TOL On/Off: Press & Release
TOL
. If no tolerances are
programmed, a large tol will be displayed & both the LOW & HI
icons will flash.
b. To Program LOW & HI tolerances: Toggle TOL On (step a.).
Press & Hold
TOL
until HI is flashing & release
TOL
.
Use
move
(2ND ),
change
(TOL),
apply
(HOLD)
to program
HI tolerance.
move
(2ND)
scrolls flashing icon left to right.
change
(TOL)
toggles value of flashing icon.
apply
(HOLD)
stores value of HI or LOW.
c. When the value is out of tolerance the numbers will flash and the
LOW or HI will flash. If the LEDs are turned on, the Green or Red
LEDs will flash for 2 seconds when in tolerance and 4 seconds
when out of tolerance. Repeat to program LOW.
d. To Disable / Enable LEDs for TOL: use the following 3 button
sequence.
1.Press & Release
2ND
2.
Press & Release
ON ZERO
3.Press & Hold
INmm
until display changes
(All On, Off, DATA, or Off will be displayed).
Use change
(TOL)
to scroll All On (LEDs will flash when using
the TOL & DATA), oFF (turned off for both TOL & DATA), tol (turned
on for tolerance only), DATA (turned on for Data only).
Use
apply
(HOLD)
to store desired setting
Note:
Factory reset: Press & Hold
ON ZERO
&
OFF
simultaneously until
RESET appears on LCD
OFF can be used to exit programming functions (Ratio, Tolerance,
Presets, Lock) Using OFF to exit will not apply changes.
After 60 seconds of inaction, programming will exit and will not
apply changes.
.