Press
To exit Limit mode when you have completed
your measurements.
LIMITS
Button
SHIFT/SET
Button
Press
Press
The LIMIT icon will stop flashing.
The Indicator is now set up with a maximum
and minimum limit range.
LIMITS
Button
Press
The MAX LIMIT icon will appear.
LIMITS
Button
Press
The LIMIT icon start flashing.
SHIT/SET
Button
9
ENGLISH
stop flashing.
11. Press the
LIMITS
button to use the go/no go
function. The display will flash unless the reading is
within the range that you set your limits to. The
SET
icon will remain on. The
MAX
and
MIN
icons will stay
off as long as the reading is within the set limits. If the
measurement is beyond the set limits, the display will
flash and the
MIN
or
MAX LIMIT
icon will indicate the
direction the limit has been exceeded. To exit Press the
LIMITS
button.
1 - To enter
Max
Limit mode.
2 - To enter the
Max
value.
Adjust the gauge using a reference surface (gage block) to the desired maximum value.
3 - To capture the maximum value;
2.2 Setting the MIN/MAX/TIR Function
The
Min/Max/TIR
(Total Indicator Reading or Run-out ) function measures the
minimum and the maximum values of a surface (usually rotating) and then calculates
the difference between them. (TIR),
Note:
This function is only available with the advanced type indicators.
1. Select the units to be displayed.
2. Bring the indicator down to the part being measured, to a point that is around half
the travel of the indicator.
3. Lock in the indicator at this height.
Note:
Care must be taken; to make sure the difference between the high and low
measurements are not outside of the travel of the indicator as setup. Either your low
measurement will be wrong or your high measurement might jam the spindle and
damage your indicator.