![STARPLUS Starplus DHS-L Скачать руководство пользователя страница 64](http://html1.mh-extra.com/html/starplus/starplus-dhs-l/starplus-dhs-l_technical-manual_1364148064.webp)
2-46
DH S-L Instal lation
Chapter 2 - Description and Installation
Caller ID Connection
The purpose of this service is to provide calling party identification to the dialed party.
This information can be the calling party’s phone number, name, or a combination of this
information. The information is delivered in between the first and second ring. The
system can use this information to provide LCD information to stations receiving calls,
and maintain a list of unanswered calls for call back via the Caller ID information.
Caller ID Box
-- When Incoming Caller ID is to be used with the
DHS-L
system it is
necessary to use the Caller ID Box. The Caller ID Box must be connected to the
DHS-L
system ICLID/PC Programming port using the Caller ID Cable. The Caller ID Box collects
data at each CO line to be used for Incoming Caller ID and passes the data to the
DHS-L
system for processing. Each
DHS-L
CO line port must be programmed for the associated
Caller ID Box port in
Customer Database Programming
.
ICLID/PC Port
-- The Caller ID Box module is connected to the
DHS-L
system via the
ICLID/PC programming port on the MPB. Consequently, the PC programming port
cannot then be used for PC-based programming and Incoming Caller ID data collection
simultaneously.
When all hardware connections are complete:
1. Adjust the Caller ID Box option switches for 1200 BPS operation.
2. Then program the
DHS-L
system PC Programming port for 1200 BPS operation. (A
proprietary cable can be ordered, or you can use a standard null modem.)
External Paging Equipment (Optional)
The system provides a one way paging output at the KSU from the MISB which connects
to two external paging ports. The input specifications for the external paging equipment
should accept a 600 ohm and 0 dBm interface.
Install the external paging equipment as follows:
1. Punch down to a 50-pair block.
2. Connect the other end of the cable to the high impedance input according to the
manufacturer’s instructions.
3. Connect the paging speaker(s) to the amplifier using speaker cable.
4. Plug in the amplifier's AC power cord. (
DO NOT use the same AC outlet being used for
the KSU).
5. Set the paging amplifier's volume control to the lowest setting and turn ON the
external amplifier.
6. From a station location, make a page by lifting the handset, and dialing 820 or 821,
the External Page feature code.
7. Adjust the amplifier to the desired level while announcing the page.
8. PAGE VOL may be adjusted to lower the output signal in the event it is to strong for
the connected amplifier input (over-driving input).
Содержание Starplus DHS-L
Страница 1: ...Technical Manual The Answer To Your Company s Growing Communication Needs DHS LTM ...
Страница 2: ......
Страница 3: ...S T A R P L U S D H S L Key Telephone System Technical Manual Issue 2 October 2001 ...
Страница 14: ... N O T E S ...
Страница 16: ......
Страница 20: ......
Страница 70: ...2 52 Feature Upgrade Procedure Chapter 2 Description and Installation ...
Страница 72: ......
Страница 220: ...3 150 Voice Mail Chapter 3 Key Station Features Operation and Programming ...
Страница 222: ......
Страница 240: ...4 20 Voice Mail Chapter 4 SLT Features and Operation ...
Страница 242: ......
Страница 254: ...5 14 Configurations Chapter 5 HOTEL MOTEL Operator Features ...
Страница 256: ......
Страница 266: ......
Страница 283: ...B Part Numbers This chapter contains the basic and optional part numbers used for the STARPLUS DHS L Systems ...
Страница 284: ......
Страница 286: ...B 4 Basic Optional Equipment Appendix B Part Numbers ...
Страница 293: ......
Страница 294: ...www vodavi com 2001 Vodavi Technology Inc Vodavi is a registered trademark of Vodavi Technology Inc ...