Starlight Xpress SXVF-H35 Скачать руководство пользователя страница 16

Handbook for the SXVF-H35       Issue 1 August 2007 

 

 

16 

below the image from light leakage in the CCD structure. To minimise this, keep the 
image brightness down with an ND filter or aperture stop, so that the exposure time is 
not less than about 0.5 seconds. A H-alpha nebula filter often gives excellent results. 
 
The exposure time needed for good lunar images is such that the image histogram has 
a peak value at around 127 and does not extend much above 200 (Ignore the major 
peak near zero, due to the dark background). If you use too short an exposure time, 
the image noise level will be increased, and if too long a time is used you will saturate 
the highlights and cause white patches on the decoded image.  
 
If you want to record an image sequence – perhaps during a lunar eclipse – you can 
set up the SX software to ‘Autosave’ an image sequence. To start the Autosave 
process, call up the SXV Camera Interface and select the ‘Continuous Mode’ check 
box at the top (make sure the rest are unchecked). Now check the ‘Autosave Image’ 
checkbox near the bottom of the window. If you now click on ‘Take Picture’ the 
automatic sequence will begin and will not stop until you press a computer key. The 
images will be saved in FITs format with sequential names such as ‘Img23, 
Img24….’ and will be found in the ‘Autosave’ directory (or a sub-directory of 
Autosave, set up in the program defaults menu).  
 
Processing a lunar image: 
 
Lunar images have one major advantage over deep sky images, when you come to 
process them – they are MUCH brighter, with a correspondingly better signal to noise 
ratio. This means that aggressive sharpening filters may be used without making the 
result look very noisy and so some of the effects of poor seeing can be neutralised. 
 
Try applying an ‘Unsharp Mask’ filter with a radius of 5 and a power of 5. This will 
often greatly increase the visibility of any detail on the moon, but the optimum radius 
and power will have to be determined by experiment. In general terms, the larger the 
image and the worse the seeing, then the wider the radius for best results. I find that 
the ‘radius 5, power 5’ values are good for most average seeing conditions. If you 
have exceptionally good conditions, then a reduction to R=3, P=3 will probably give a 
more natural look to the image, as too large a radius and power tends to outline edges 
with dark or bright borders. As a finishing touch, the application of a Median filter or 
a Weighted Mean Low Pass filter can be useful to smooth out the high frequency 
noise after a strong Unsharp Mask. 
 
********************************************************************* 

Other features of SXV_H35 

 
‘Slew & Sum’ imaging: 
 
The SXVF-H35 can be used in an automatic image-stacking mode, called ‘Slew & 
Sum’. The camera is set to take several sequential exposures, which are automatically 
‘slewed’ into alignment and then summed together by the software. This mode can 
help to overcome a poor RA drive by summing images that have exposure times 
shorter than the drive error period. The resulting image has more noise than a single 
exposure of the same total length, but this method of imaging is still an effective way 
of making long exposures. 

Содержание SXVF-H35

Страница 1: ...stronomical imaging The SXVF H35 uses a Kodak KAI11002 Interline CCD with 4008 x 2672 pixels in a 36 1mm x 24 05mm active area The use of high performance microlenses on the CCD surface gives the grea...

Страница 2: ...blies 5 An adaptor for 2 drawtubes and M42 Pentax thread lenses 6 A guider cable for ST4 style mount guiding inputs 7 A CD with the SXVF_H35 software and manual You will also need a PC computer with W...

Страница 3: ...Handbook for the SXVF H35 Issue 1 August 2007 3 A rear view showing the input and output connectors...

Страница 4: ...B drivers required by the SXVF electronics The files SXVIO sys and Generic sys are copied to your Windows System32 Drivers folder and SXVIO_H35 inf is copied to Windows Inf After this the program SXV_...

Страница 5: ...ult settings are not important for current purposes and may be left as the software start up values for now Recording your first image We now have the camera and computer set up to take pictures but a...

Страница 6: ...ly exposed but any sort of image is better than none In the case of the pinhole all that you can experiment with is the exposure time but a camera lens can be adjusted for good focus and so you might...

Страница 7: ...ious filters and contrast operations In the case of daylight images the processing options are many but there are few that will improve the picture in a useful way The most useful of these are the Nor...

Страница 8: ...pplied with an M72 spacer ring to screw into the FSQ106 focus assembly Here is a view of an SXVF H35 attached to the author s FSQ via the adaptor ring As a general guide most CCD astronomers try to ma...

Страница 9: ...amera interface window and click on Start in the Focus frame The computer will now display a continuous series of 100 x 100 pixel images in the focus window and you should see your selected star appea...

Страница 10: ...menu and save it in a convenient directory Now you need a dark frame if the best results are to be extracted from your raw image To take this just cover the telescope objective with the lens cap or d...

Страница 11: ...e deep sky image Below you will see typical examples of a dark frame and an uncalibrated raw image of M16 A typical 5 minute dark frame exposure Note the random scatter of warm pixels A 5 minute expos...

Страница 12: ...ccurately match your darks to the light image If you average many dark frames together to create a master dark the readout noise will be much reduced by the square root of the number of averaged darks...

Страница 13: ...ftware at the time of writing but Maxim DL can use this method The basic procedure is to capture a long exposure dark frame and then slice off all values below a threshold level which is selected so a...

Страница 14: ...l to noise ratio Summing can be done in the Merge menu and involves loading the first finished image selecting a reference point a star then loading the second image and finding the same star with the...

Страница 15: ...ocker for the front of the lens it is often quite acceptable to place a small one behind the lens inside the adaptor tube Taking pictures of the Moon and planets The SXVF H35 is not intended for plane...

Страница 16: ...deep sky images when you come to process them they are MUCH brighter with a correspondingly better signal to noise ratio This means that aggressive sharpening filters may be used without making the r...

Страница 17: ...focal reducers are used This causes a brighter centre to show in images especially when there is a lot of sky light to illuminate the field If dust motes are your main problem it is best to clean the...

Страница 18: ...ed in the bias any very short exposure dark frame will give a good result The dark subtracted images should then be averaged together before use After the above procedures have been executed the flat...

Страница 19: ...mounted alongside your imaging telescope I personally use it with an 80mm aperture F5 inexpensive refractor as a guide scope but a shorter focal length lens will make more guide stars available in any...

Страница 20: ...on a 80mm refractor guide scope in the author s garden To use the autoguider please proceed as follows 1 Having started the SXVF H35 software open the autoguider control panel by clicking on the autog...

Страница 21: ...scope and mount You have the option of manually selecting values or asking the software to attempt to determine what they should be This is done by pressing the Train button and waiting for the softwa...

Страница 22: ...ll CCD equipment are likely to show up on occasion These are dust and condensation Removing Dust 1 Dust can be deposited on either the optical window not a big problem to cure or on the CCD faceplate...

Страница 23: ...compound is applied to the periphery of the heat sink disc and this should be left undisturbed by subsequent operations 5 You can now closely examine the CCD faceplate under the spotlight using the wa...

Страница 24: ...ough we hope that you will be satisfied with the SXV_Hmf_usb software other companies are offering alternative programs One of the most active and successful of these is AstroArt by MSB software You c...

Страница 25: ...CCD characteristics CCD type Kodak KAI 11002 interline CCD imager CCD size Active area 36 3 x 24 2mm Pixel size 9 x 9uM QE peak approx 52 at 500nM Spectral response Dark signal Typically 0 01 e per s...

Страница 26: ...nly be used for normal purposes described in the standard operating instructions and within the relevant safety standards of the country where the equipment is used 2 Repairs under guarantee will be f...

Отзывы: