Stark 75140 Скачать руководство пользователя страница 5

4

SAND FILTRATION WORKING PRINCIPLE

Incoming water from the piping system is automatically directed by the multi-port valve to the top of the 

filter bed. As the water is pumped through the filter sand, dirt and debris are trapped by the filter bed, and 

filtered out. The filter water is returned from the bottom of the filter tank., through the multi-port and back 

through the piping system .

PREPARATION BEFORE INSTALLATION

1. Position the filter as close to the swimming pool / spa as possible.
2. The filter should be placed on a level concrete slab, very firm ground, or equivalent. Ensure that the 

ground will not subside to prevent any strain to the attached plumbing.

3. Position the filter so that the piping connections, Multi-Port Valve and winter drain is convenient and 

accessible for operation, servicing and winterizing.

4. Ensure that the compliance label is facing the front to allow easy identification in the case of

service difficulties.

INSTALLATION

INSTALLATION

WARNING: 

This product should be installed and serviced only by a qualified professional.

1. Put the filter tank on the base. Turn the filter tank to the right to tighten it. Position the outlet drain plug

so it is facing outside for easy operation.

2. Before filling the filter media into the filter vessel, do a visual check of the laterals. Look for broken or

loose laterals. Replace if necessary. The laterals of side-mount valve sand filter are all installed.

3. Match the Raised Point of the laterals to Folding Umbrella lateral holder, insert the laterals and turn

90º clockwise. Listen for a sound to confirm the lateral is in place. 

4. Make sure the air release hose is running along side the body of the lateral holder. One end of the

air release hose 

MUST

 be out of the sand. 

DO NOT

 bury the air release hose in the sand.

5. To eliminate stress on the laterals, fill the filter vessel with enough water to provide a cushioning

effect when the filter sand is poured in.

6. Use Sand Shield to protect the filter top mount and make sure the central stem pipe has been fully 

covered.

7. Carefully pour the exact amount of sand into the filter vessel. 

DO NOT

 allow sand to go into the stem 

pipe. 

DO NOT

 damage the filter top mount or it can cause a leak.

8. Put the O-Ring on the top mount valve and then connect the valve on the filter vessel. The

stem pipe should be straight and aligned with the top mount valve. Tighten the flange clamp on the

valve. 

NOTE

: The flange clamp should be in place and tight or it could cause injuries.

9. To connect the pump to the base, use the screws from the pump hardware pack. 

10. Adjust the valve position. The pressure hose connects to the pump output/input valve.

11. The other two connection ends of the valve connect to the swimming pool and the drain outlet hose.

Содержание 75140

Страница 1: ...ING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 75140 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 4900 MON FRI 9AM TO 3PM PST ...

Страница 2: ...difications of this filter requires prior consent from the supplier s original replacement and accessories authorized by the manufacturer to ensure a high level of safety The supplier assumes no liability for any damage or injuries caused by unauthorized replacement parts and or accessories In the even of defective operation or fault contact the supplier or the nearest authorized service agent Com...

Страница 3: ...um Release Systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems and or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems SVRS for Swimming Pools Spas and Hot Tubs or ii A properly designed and tested suction limiting vent system or iii An automatic pump shut off system Pools and spas constructed prior to December 20 20...

Страница 4: ...ner Air entering the filter and the valve not clamped correctly can cause the valve to separate which could cause serious personal injury and or property damage Always turn pump off before changing valve positions Changing valve positions while the pump is running can damage the control valve which may cause serious injury or property damage Chemical fumes and or spills can cause serious corrosion...

Страница 5: ... visual check of the laterals Look for broken or loose laterals Replace if necessary The laterals of side mount valve sand filter are all installed 3 Match the Raised Point of the laterals to Folding Umbrella lateral holder insert the laterals and turn 90º clockwise Listen for a sound to confirm the lateral is in place 4 Make sure the air release hose is running along side the body of the lateral ...

Страница 6: ...screws and O Ring 1 Screw the barrel unions onto the threaded ports on the Multi port Valve 2 When rotating the Multi port Valve into position on a Top Mount Filter leave some leeway for better alignment of plumbing 3 Once the Multi port Valve is in position and the plumbing is aligned apply the thread tape to the barrel union thread 4 Using a roll of Teflon tape wrap the Teflon tape around the th...

Страница 7: ... waste etc 4 To prevent water leakage be sure winter drain cap is securely in place and all pipe connections are tight BACKWASHING CONDITIONS WARNING ALL SUCTION AND DISCHARGE VALVES MUST BE OPEN WHEN STARTING THE SYSTEM FAILURE TO DO SO COULD CAUSE SEVERE PERSONAL INJURY Once water flow is steady out the waste line run the pump for at least 2 minutes The initial back washing of the filter is reco...

Страница 8: ...TROUBLESHOOTING GUIDES 7 PROBLEM SOLVING TABLE ...

Страница 9: ...ACEMENT PARTS THERETO Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead 8 FEATURES FEATURES AND SPECIFICATIONS Flange clamp design allows 360 degree rotation of valve to simplify plumbing Unitized corrosion proo...

Отзывы: