IMPORTANT SAFETY INFORMATION

2

HIGH PRESSURE FROM THE SAND FILTER CAN CAUSE SEVERE INJURY OR MAJOR 

PROPERTY DAMAGE DUE TO TANK SEPARATION. RELEASE ALL PRESSURE AND READ 

INSTRUCTIONS BEFORE WORKING ON THE SAND FILTER. IF THE FILTER CLAMP IS 

ADJUSTED UNDER PRESSURE, THE TANK CAN SEPARATE, CAUSING SERIOUS INJURY 

OR MAJOR PROPERTY DAMAGE.
PUMPS REQUIRE HIGH VOLTAGE WHICH CAN SHOCK, BURN, OR CAUSE DEATH. BEFORE 

WORKING ON PUMP! ALWAYS DISCONNECT POWER TO THE POOL PUMP AT THE CIRCUIT 

BREAKER BEFORE SERVICING THE PUMP. FAILURE TO DO SO COULD RESULT IN DEATH 

OR SERIOUS INJURY TO SERVICE PERSON, POOL USERS OR OTHERS DUE TO ELECTRIC 

SHOCK.

The Virginia Graeme Baker Pool and Spa Safety Act imposes certain new requirements on owners and 

operators of swimming pools and spas. Pools or spas constructed on or after December 20, 2008, shall 

utilize:

(A) No submerged suction outlets, a gravity drainage system with ASME/ANSI cover(s), one or more 

unblock-able outlets; or

(B) A multiple main drain system without isolation capability with suction outlet covers that meet ASME/

ANSI A112.19.8 Suction Fittings for Use in Swimming Pools, Wading Pools, Spas, and

Hot Tubs and either:

(I)  A  safety  vacuum  release  system  (SVRS)  meeting  ASME/ANSI  A112.19.17  Manufactured  Safety 

Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub, and 

Wading  Pool  Suction  Systems  and/or ASTM  F2387  Standard  Specification  for  Manufactured  Safety 

Vacuum Release Systems (SVRS) for Swimming Pools, Spas and Hot Tubs or

(ii) A properly designed and tested suction-limiting vent system or

(iii) An automatic pump shut-off system.

Pools and spas constructed prior to December 20, 2008, with a single submerged suction outlet shall 

use a suction outlet cover that meets ASME/ANSI A112.19.8 and either:

(A) A multiple main drain system without isolation capability, or

(B) A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or

(C) A properly designed and tested suction-limiting vent system, or

(D) An automatic pump shut-off system, or

(E) Disabled submerged outlets, or

(F) Suction outlets shall be reconfigured into return inlets.

Separation Hazard.

 Failure to follow safety and operation instructions could result in violent separation 

of pump and/or filter components. Strainer cover must be properly secured to pump housing with strainer 

cover lock ring. Before servicing pool and spa circulation system, filters manual air relief valve must be in 

open position. 

DO NOT

 operate pool and spa circulation system if a system component is not assembled 

properly, damaged, or missing. 

DO NOT

 operate pool and spa circulation system unless filter manual air 

relief valve body is in locked position in filter upper body.

Содержание 75140

Страница 1: ...ING INSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 75140 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 4900 MON FRI 9AM TO 3PM PST ...

Страница 2: ...difications of this filter requires prior consent from the supplier s original replacement and accessories authorized by the manufacturer to ensure a high level of safety The supplier assumes no liability for any damage or injuries caused by unauthorized replacement parts and or accessories In the even of defective operation or fault contact the supplier or the nearest authorized service agent Com...

Страница 3: ...um Release Systems SVRS for Residential and Commercial Swimming Pool Spa Hot Tub and Wading Pool Suction Systems and or ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release Systems SVRS for Swimming Pools Spas and Hot Tubs or ii A properly designed and tested suction limiting vent system or iii An automatic pump shut off system Pools and spas constructed prior to December 20 20...

Страница 4: ...ner Air entering the filter and the valve not clamped correctly can cause the valve to separate which could cause serious personal injury and or property damage Always turn pump off before changing valve positions Changing valve positions while the pump is running can damage the control valve which may cause serious injury or property damage Chemical fumes and or spills can cause serious corrosion...

Страница 5: ... visual check of the laterals Look for broken or loose laterals Replace if necessary The laterals of side mount valve sand filter are all installed 3 Match the Raised Point of the laterals to Folding Umbrella lateral holder insert the laterals and turn 90º clockwise Listen for a sound to confirm the lateral is in place 4 Make sure the air release hose is running along side the body of the lateral ...

Страница 6: ...screws and O Ring 1 Screw the barrel unions onto the threaded ports on the Multi port Valve 2 When rotating the Multi port Valve into position on a Top Mount Filter leave some leeway for better alignment of plumbing 3 Once the Multi port Valve is in position and the plumbing is aligned apply the thread tape to the barrel union thread 4 Using a roll of Teflon tape wrap the Teflon tape around the th...

Страница 7: ... waste etc 4 To prevent water leakage be sure winter drain cap is securely in place and all pipe connections are tight BACKWASHING CONDITIONS WARNING ALL SUCTION AND DISCHARGE VALVES MUST BE OPEN WHEN STARTING THE SYSTEM FAILURE TO DO SO COULD CAUSE SEVERE PERSONAL INJURY Once water flow is steady out the waste line run the pump for at least 2 minutes The initial back washing of the filter is reco...

Страница 8: ...TROUBLESHOOTING GUIDES 7 PROBLEM SOLVING TABLE ...

Страница 9: ...ACEMENT PARTS THERETO Note Some parts are listed and shown for illustration purposes only and are not available individually as replacement parts Record Product s Serial Number Here Note If product has no serial number record month and year of purchase instead 8 FEATURES FEATURES AND SPECIFICATIONS Flange clamp design allows 360 degree rotation of valve to simplify plumbing Unitized corrosion proo...

Отзывы: