![Stark 71038 Скачать руководство пользователя страница 6](http://html.mh-extra.com/html/stark/71038/71038_owners-manual-and-safety-instructions_1363658006.webp)
SETUP AND INSTALLATION
The suction line should ascend steadily toward the pump to prevent air pockets.
Sufficient water supply must be assured; the end of the suction line should always be in water.
All components of the pressure line must be compression-proof.
All components of the pressure line must be professionally installed.
DANGER:
Avoid damage to the device. The suction line must be installed so
that it does not exert any mechanical force or tension on the pump.
The device can also be connected firmly to a pipe system (domestic water supply in the interior). In this
case, the device should be connected to the pipe sytem with elastic high pressure flexible hose lines in
order to prevent vibrations.
DANGER:
If components are not compression-proof or if they are improperly
installed, the pressure line can burst causing serious injury. Seek professional help if
you are unsure.
OPERATING THE DEVICE
1. Unscrew the pump cover
2. Fill completely with water
3. Reinstall the filter and screw on the pump cover and seal back on
4. To shorten the intake time, fill the suction line as well
5. Open the pressure line so the air can escape during intake
6. Switch the device on
7. When the water runs out evenly, switch the device off
For better performance, installing a check line valve between the pump and suction line is
recommended so that the water column remains in the suction line.
If Domestic Water Works is installed directly in the water distribution network, it is important that the
water pressure from this network is added to the pump pressure. A total pressure of 6 bar must not
be exceeded.
NOTE
: The boiler includes rubber bellows, which is under air pressure from the manufacturer. This
enables small amounts of water to be removed without starting up the pump. Check the pressure
before operating the pump and increase if necessary. The pump must not be placed in direct sunlight
as this could result in too high pressure.
1. Plug in the mains plug
2. Open the pressure line (turn on the spigot or nozzle)
3. Turn on the pump at the ON/OFF switch
4. Check to be sure water is coming out.
If the motor does not start up or the pump does not build up any pressure or if similar faults occur, turn
the device off and try to remedy the error.
The pump is equipped with a pressure switch. This turns the pump on if the water pressure in the
boiler drops below the start-up pressure due to water removal. The pressure switch turns the pump
off when the shutoff pressure is reached.
NOTE
: The pressure switch is preset to the correct start-up and shutoff pressure by the manufacturer.
5