Stark 71038 Скачать руководство пользователя страница 6

SETUP AND INSTALLATION

The suction line should ascend steadily toward the pump to prevent air pockets. 

Sufficient water supply must be assured; the end of the suction line should always be in water. 

All components of the pressure line must be compression-proof. 

All components of the pressure line must be professionally installed. 

DANGER: 

Avoid damage to the device. The suction line must be installed so 

that it does not exert any mechanical force or tension on the pump.

The device can also be connected firmly to a pipe system (domestic water supply in the interior). In this 

case, the device should be connected to the pipe sytem with elastic high pressure flexible hose lines in 

order to prevent vibrations. 

DANGER: 

If components are not compression-proof or if they are improperly 

installed, the pressure line can burst causing serious injury. Seek professional help if 

you are unsure. 

OPERATING THE DEVICE

1. Unscrew the pump cover 
2. Fill completely with water
3. Reinstall the filter and screw on the pump cover and seal back on

4. To shorten the intake time, fill the suction line as well  

5. Open the pressure line so the air can escape during intake
6. Switch the device on
7. When the water runs out evenly, switch the device off

For better performance, installing a check line valve between the pump and suction line is 

recommended so that the water column remains in the suction line. 

If Domestic Water Works is installed directly in the water distribution network, it is important that the 

water pressure from this network is added to the pump pressure. A total pressure of 6 bar must not 

be exceeded. 

NOTE

: The boiler includes rubber bellows, which is under air pressure from the manufacturer. This 

enables small amounts of water to be removed without starting up the pump. Check the pressure 

before operating the pump and increase if necessary. The pump must not be placed in direct sunlight 

as this could result in too high pressure. 

1. Plug in the mains plug
2. Open the pressure line (turn on the spigot or nozzle)
3. Turn on the pump at the ON/OFF switch

4. Check to be sure water is coming out. 
If the motor does not start up or the pump does not build up any pressure or if similar faults occur, turn 

the device off and try to remedy the error. 
The pump is equipped with a pressure switch. This turns the pump on if the water pressure in the 

boiler drops below the start-up pressure due to water removal. The pressure switch turns the pump 

off when the shutoff pressure is reached. 

NOTE

: The pressure switch is preset to the correct start-up and shutoff pressure by the manufacturer. 

5

Содержание 71038

Страница 1: ...NSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 71038 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Страница 2: ...K This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle Risk of electric shock This pump has not been investigated for use in swimming pool areas Electrical connections must beprotected from moisture If there is danger of flooding the electrical connections must be taken...

Страница 3: ... supply corresponds with the connection specifications of the device before it is connected This pump may only be used within the specified limitations for voltage and power see the type plate Check the plug and cable before each use If the power cable is damaged immediately disconnect the plug Never use this device if the power cord is damaged Unplug the power cord when the device is not in use o...

Страница 4: ...nternational safety health and working regulations Do not allow this device to get wet Do not leave this device unattended unplug the device when not in use Repairs should only be made by a qualified technician and or electrician Read and observe all safety instructions and warnings prior to using the device Never use this device near explosives or flammable materials COMPONENTS Install indoors or...

Страница 5: ...ealed Bubbles in the hose is an indication that there may be leaks and may lead to device malfunction The suction line must be installed so that it does not exert any mechanical force or tension on the pump If the conveying medium is contaminated a suction filter must be used to pump from sand and dirt NOTE A check valve is recommended so that the water does not run off when the pump is shut off A...

Страница 6: ... runs out evenly switch the device off For better performance installing a check line valve between the pump and suction line is recommended so that the water column remains in the suction line If Domestic Water Works is installed directly in the water distribution network it is important that the water pressure from this network is added to the pump pressure A total pressure of 6 bar must not be ...

Страница 7: ...onnection and pressure gauge 4 Pump up or inflate to the designated preliminary filling pressure Preliminary filling pressure 1 8 2 0 bar Unscrew filter housing A and take out the filter cartidge If necessary soak the cartridge in warm water Rinse the filter cartidge with clean water brush out stubborn dirt from inside the cartridge using a soft brush DANGER If the conveyed water is highly contami...

Страница 8: ...TROUBLESHOOTING 7 ...

Страница 9: ...PRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial n...

Отзывы: