GROUNDING INSTRUCTIONS

To prevent electric shock and death from incorrect grounding 

wire connection read and follow these instructions:

Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. 

Do not modify the power cord plug provided with the tool. Never remove the grounding prong from 

the plug. Do not use the tool if the power cord or plug is damaged. If damaged, have it repaired by a 

service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified 

electrician.

The tool must be plugged into an appropriate outlet, properly installed and grounded in accordance 

with all codes and ordinances. 

The outlet must be properly installed and grounded in accordance with all codes and ordinances.

Do not use extension cords with this pump.

Do not use an adapter to connect this pump to a different outlet.

The fuse must be a residual current circuit-breaker with a measured residual current of no more than 

30 mA. 
Make sure the power supply corresponds with the connection specifications of the device before it is 

connected. 
This pump may only be used within the specified limitations for voltage and power, see the type plate.

Check the plug and cable before each use. 

If the power cable is damaged, immediately disconnect the plug. Never use this device if the power 

cord is damaged. 
Unplug the power cord when the device is not in use or when transporting.  

SAFETY INSTRUCTIONS 

CAUTION

: This pump has been evaluated for use with water only.

Fluid Type:

 The Pump is designed for use with water with a maximum temperature of 77° F (25° C).

Do not use the pump for other fluids, especially not fuels, cleaning fluids, or other chemical products.

NOT FOR POTABLE WATER

This device is not intended to be used for providing drinking water nor for food items.
Exposive, combustable, fecal matter or aggressive materials or substances which are hazardous 

must not be conveyed by the device. 

This device is not to be used for commercial or industrial use.  
Improper use or modifications to this device or the use of components not included with this device or 

use of components that are not tested and approved by the manufacturer may result in damage and/

or serious injury. 

2

Содержание 71038

Страница 1: ...NSPECTION MAINTENANCE AND CLEANING PROCEDURES WRITE THE PRODUCT S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER OWNER S MANUAL AND SAFETY INSTRUCTIONS ITEM 71038 FOR QUESTIONS PLEASE CALL OUR CUSTOMER SUPPORT 909 628 0880 MON FRI 9AM TO 3PM PST ...

Страница 2: ...K This pump is supplied with a grounding conductor and grounding type attachment plug To reduce the risk of electric shock connect only to a properly grounded grounding type receptacle Risk of electric shock This pump has not been investigated for use in swimming pool areas Electrical connections must beprotected from moisture If there is danger of flooding the electrical connections must be taken...

Страница 3: ... supply corresponds with the connection specifications of the device before it is connected This pump may only be used within the specified limitations for voltage and power see the type plate Check the plug and cable before each use If the power cable is damaged immediately disconnect the plug Never use this device if the power cord is damaged Unplug the power cord when the device is not in use o...

Страница 4: ...nternational safety health and working regulations Do not allow this device to get wet Do not leave this device unattended unplug the device when not in use Repairs should only be made by a qualified technician and or electrician Read and observe all safety instructions and warnings prior to using the device Never use this device near explosives or flammable materials COMPONENTS Install indoors or...

Страница 5: ...ealed Bubbles in the hose is an indication that there may be leaks and may lead to device malfunction The suction line must be installed so that it does not exert any mechanical force or tension on the pump If the conveying medium is contaminated a suction filter must be used to pump from sand and dirt NOTE A check valve is recommended so that the water does not run off when the pump is shut off A...

Страница 6: ... runs out evenly switch the device off For better performance installing a check line valve between the pump and suction line is recommended so that the water column remains in the suction line If Domestic Water Works is installed directly in the water distribution network it is important that the water pressure from this network is added to the pump pressure A total pressure of 6 bar must not be ...

Страница 7: ...onnection and pressure gauge 4 Pump up or inflate to the designated preliminary filling pressure Preliminary filling pressure 1 8 2 0 bar Unscrew filter housing A and take out the filter cartidge If necessary soak the cartridge in warm water Rinse the filter cartidge with clean water brush out stubborn dirt from inside the cartridge using a soft brush DANGER If the conveyed water is highly contami...

Страница 8: ...TROUBLESHOOTING 7 ...

Страница 9: ...PRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS SHOULD BE UNDERTAKEN BY CERTIFIEDAND LICENSED TECHNICIANS AND NOT BY THE BUYER THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO Record Product s Serial Number Here Note If product has no serial n...

Отзывы: