21
6.2 Parameter description
After starting the machine, press [F4] → [F6] to enter the screen of setting up parameters. The parameters are as
follows:
Built in height adjustment (open 1 / close 0): set the built-in height adjustment to 1, not used to 0, and the default
value is 0;
Dead band voltage (0.1-10.0v): when the difference between the set value of arc voltage and the actual value is less
than this set value, the cutting gun height will not be adjusted, and the default value is 1.0.
Increase sensitivity (1-10): the greater the setting value, the greater the adjustment range of the cutting gun. The
default value is 1.
Manual lifting speed: the speed at which the height is manually adjusted. The default value is 200.
Automatic lifting speed: the speed at which the height is automatically adjusted. The default value is 200.
Positioning rise rate: increases the rise rate when positioning. The default value is 200.
Positioning switch 0 low effective / 1 high effective: 0 switch signal low level is effective, 1 switch signal high level is
effective, and the default value is 0;
Upper limit switch 0 low effective / 1 high effective: 0 switch signal low level effective, 1 switch signal high level
effective, the default value is 0;
Lower limit switch 0 low effective / 1 high effective: 0 switch signal low level effective, 1 switch signal high level
effective, the default value is 0;