Features & Benifits

The CV Vent is designed to improve the environment for kitchen staff and patrons by removing smoke, odors, 

moisture and grease laden vapors from the ambient air.  It works with compact countertop cooking appliances such 

as convection ovens, toasters, Panini grills and griddles.  The SA Vent unit operates from a standard 120V outlet, and 

draws .5A.  It comes with a preinstalled NEMA 5-15P cord.  The platform will hold equipment up to 150 lbs. and 25 

½” W x 18” D.  The unit is equipped with interlock switches to insure that three all filters, and the front filter panel, are 

installed and correctly positioned in order to operate.

The air filtering system consists of the following three filters.

•  Washable grease filter
•  Disposable electrostatic particulate filter
•  Disposable activated charcoal smoke filter

The Grease impinges upon the baffles and drains downward. Holes in the frame bottom divert the grease into a 

trough and to a container away from the fire danger area.

Installation:

The CV Vent is shipped assembled, except for the filters.  Remove from packing materials and make sure the unit is 

complete and undamaged.  The SA Vent must be installed on a level surface, away from sources of excessive heat 

and moisture.  Insure that nothing is blocking the air intake cutouts that provide cooling of the motor, or the air exhaust 

ports.

The grease filter is installed at a 45-degree angle, to allow grease to flow freely down the baffles and through the drain 

holes.  The grease channel below the filter is at a slight angle to allow the grease to run into the trap without pooling.

Operation:

First, make sure that the filters are correctly installed in the unit. 

Remove the front panel by grasping the knobs and sliding it upward 

until the bottom is free, then move the whole panel downward, while 

pulling the knobs gently towards you, until it is off the unit. Insure 

that the filters are all in place, and fully seated. The bottom filter is 

the activated charcoal filter, the center is the particulate filter, and 

the large metal filter on the top is the grease filter. The grease filter 

should be installed with the holes that are punched in one side facing 

toward the bottom of the unit, over the grease channel. Holes in the 

frame bottom divert the grease into a trough and to a container away 

from the fire danger area. Please note that the removable grease 

drawer must be in place. Reinstall the filter cover by reversing the 

removal procedure. Plug the unit into an appropriate outlet, and flip 

the lighted power switch, located on the right side of the unit, to the 

on position. Unit is now ready to filter grease-laden vapors.

Filter Cleaning:

For moderate-use applications, run the grease filter through the dishwasher daily. For heavy use applications, 

presoaking in a detergent solution prior to dishwasher cleaning is commended.  The electrostatic and carbon pleated 

filters are disposable.

DO NOT spray the unit with any cleaning liquid before unplugging it

DO NOT allow water to drip into the housing or around the electrical 

components

DO NOT immerse in water for cleaning

CAUTION

Grease Drawer

Power Cord

On/Off Switch

Air Intake

Front Panel

Base

Содержание Vent-Max CV1R

Страница 1: ...Vent Max t Max Vent Max Vent Max Ven COUNTERTOP VENTILATION SYSTEM MODEL CV1R CV1L Installation and Operation Instructions 2M Z16152 Rev 7 17 12 CV1R ...

Страница 2: ...ate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Please record the model number serial number voltage and purchase dat...

Страница 3: ... unit in perfect condition If equipment is received in damaged condition either apparent or concealed a claim must be made with the delivering carrier Concealed damage or loss if damage or loss is not apparent until after equipment is unpacked a request for inspection of concealed damage must be made with carrier within 15 days Be certain to retain all contents plus external and internal packaging...

Страница 4: ...ough the drain holes The grease channel below the filter is at a slight angle to allow the grease to run into the trap without pooling Operation First make sure that the filters are correctly installed in the unit Remove the front panel by grasping the knobs and sliding it upward until the bottom is free then move the whole panel downward while pulling the knobs gently towards you until it is off ...

Страница 5: ... dampened with soap and water or equivalent 6 Replace top filters front panel reinsert grease cup and remember to refasten rear clips Wiring Diagram SIZE TWO PLACE DECIMAL THREE PLACE DECIMAL DATE 015 DESCRIPTION DATE DATE PROJECT A APPROVED BY INITIAL RELEASE CHECKED BY B DRAWN BY REV Ideas Well D SIZE DATE PART NO PROJECTION SCALE 030 FINISH TITLE HERON MAY BE COVERED BY PATENTS ISSUED OR PENDIN...

Страница 6: ...tallic utensils or abrasive cleaners abrasive pads product identifiers and point of sale attachments or any other non food object tha comes in continuous contact with the roller coating This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalog items only Star s warranty on Special Products is six 6 months on p...

Страница 7: ...1 Cord Connection 2E Z16145 per 1ft Wiring 2E Z16146 1 Connections 2E Z16147 1 Power Cord 120V W plug 5 15P 2I Z16142 2 Bumper 2I Z16149 1 Grease Filter 2I Z16150 1 Particulate Filter 7 3 4 x 22 1 2 x 1 1 2 2I Z16151 1 Carbon Filter 8 1 8 x 22 1 2 x 3 4 2M Z16152 1 Manual 2M Z16803 1 Label 2R Z16141 4 Feet 2R Z16143 3 Knobs 2R Z16148 1 Hardware PKG screws nuts misc 2U Z16097 1 Blower Fan Housing 2...

Страница 8: ... STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com ...

Отзывы: