2M-Z16152, V
ent-Max, Countertop V
entilation System
Features & Benifits
The CV Vent is designed to improve the environment for kitchen staff and patrons by removing smoke, odors,
moisture and grease laden vapors from the ambient air. It works with compact countertop cooking appliances such
as convection ovens, toasters, Panini grills and griddles. The SA Vent unit operates from a standard 120V outlet, and
draws .5A. It comes with a preinstalled NEMA 5-15P cord. The platform will hold equipment up to 150 lbs. and 25
½” W x 18” D. The unit is equipped with interlock switches to insure that three all filters, and the front filter panel, are
installed and correctly positioned in order to operate.
The air filtering system consists of the following three filters.
• Washable grease filter
• Disposable electrostatic particulate filter
• Disposable activated charcoal smoke filter
The Grease impinges upon the baffles and drains downward. Holes in the frame bottom divert the grease into a
trough and to a container away from the fire danger area.
Installation:
The CV Vent is shipped assembled, except for the filters. Remove from packing materials and make sure the unit is
complete and undamaged. The SA Vent must be installed on a level surface, away from sources of excessive heat
and moisture. Insure that nothing is blocking the air intake cutouts that provide cooling of the motor, or the air exhaust
ports.
The grease filter is installed at a 45-degree angle, to allow grease to flow freely down the baffles and through the drain
holes. The grease channel below the filter is at a slight angle to allow the grease to run into the trap without pooling.
Operation:
First, make sure that the filters are correctly installed in the unit.
Remove the front panel by grasping the knobs and sliding it upward
until the bottom is free, then move the whole panel downward, while
pulling the knobs gently towards you, until it is off the unit. Insure
that the filters are all in place, and fully seated. The bottom filter is
the activated charcoal filter, the center is the particulate filter, and
the large metal filter on the top is the grease filter. The grease filter
should be installed with the holes that are punched in one side facing
toward the bottom of the unit, over the grease channel. Holes in the
frame bottom divert the grease into a trough and to a container away
from the fire danger area. Please note that the removable grease
drawer must be in place. Reinstall the filter cover by reversing the
removal procedure. Plug the unit into an appropriate outlet, and flip
the lighted power switch, located on the right side of the unit, to the
on position. Unit is now ready to filter grease-laden vapors.
Filter Cleaning:
For moderate-use applications, run the grease filter through the dishwasher daily. For heavy use applications,
presoaking in a detergent solution prior to dishwasher cleaning is commended. The electrostatic and carbon pleated
filters are disposable.
DO NOT spray the unit with any cleaning liquid before unplugging it
DO NOT allow water to drip into the housing or around the electrical
components
DO NOT immerse in water for cleaning
CAUTION
Grease Drawer
Power Cord
On/Off Switch
Air Intake
Front Panel
Base