Star PRNT Command Specifications
2-94
<
Function 52
>
ESC GS ) I pL pH fn d1 d2
[Name] Transmit external device information
[Code]
ASCII
ESC GS )
I
pL pH fn d1 d2
Hex.
1B
1D 29
49 pL pH fn d1 d2
Decimal
27
29
41
73 pL pH fn d1 d2
[Defined range]
pL = 3, pH = 0
fn = 52
d1 = 0, d2 = 0
[Function]
Transmits information about the external device connected to the printer.
[Detail]
Information is transmitted in the following format:
ESC GS ) I pL pH fn k1 k2 [external device information1, external device information 2 , …..] LF NUL
k1 and k2 indicate the number of transmission data bytes (k1 + k2 * 256) after the external device
information.
When there are a lot of information about external devices, they are delimited by commas (2Ch).
Example: When a MCS10 is connected to the external device and the MCS10 FW version is 1.0.
ESC GS ) I pL pH fn k1 k2 DkMdl=MCS10 , DkVer=1.0 , LF NUL (k1 = 24, k2 =0
)
When an external device is not connected or when a connected external device is not supported by this
function, only the tags related to the corresponding external device are transmitted.
Example: When an external device is not connected to the external device connection terminal of a
model that supports tags DkMld and DkVer.
ESC GS ) I pL pH fn k1 k2 DkMdl=, DkVer=, LF
NUL
Tag
Parameter information
DkMdl
External device connection terminal
Connected device model information
Model Name
:
MCS10
:
DkMdl=MCS10
When these tags are transmitted from the
printer, the data for tag DkVer is also
transmitted.
DkVer
External device connection terminal
Connected device version information
When these tags are transmitted from the
printer, the data for tag DkMdl is also
transmitted.