Star PRNT Command Specifications
2-92
<Function 50> ESC GS ) I pL pH fn
[Name] Transmit the remaining battery power
[Code]
ASCII
ESC GS
)
I pL pH fn
Hex.
1B 1D
29 49 pL pH fn
Decimal
27
29
41 73 pL pH fn
[Defined range]
pL = 1, pH = 0
fn = 50
[Function]
Transmit the remaining battery power.
[Detail]
Information is transmitted in the following format:
ESC GS ) I pL pH fn [Tag name = parameter, Tag name = parameter,…] LF NUL
Each parameter is accompanied by the tag name on the top and sent correspondingly to its tag name.
The tag name is followed by an equal sign and the subsequent part is the parameter.
Each set of a tag and a parameter is separated by a delimiter “, “ (2CH).
The number of parameters varies depending on the printer which is transmitting information.
Information (a set of a tag and a parameter) is transmitted in order from the top of the list shown below
only if it corresponds to the printer.
LF NUL represents a termination, and the tag and its parameter are not transferred afterward.
The parameter is transmitted as a character string.
When a battery is empty.
ESC GS ) I pL pH fn PrBtY=Empty LF NUL
When information can't be acquired, the data below is sent.
ESC GS ) I pL pH fn LF
NUL
Sent order
Tag
Parameter information
↓
PrBtY
Remaining battery power
Near Empty: PrBtY=Empty
Low: PrBtY=Low
High: PrBtY=High
Full: PrBtY=Full
↓
(Undefined) (Undefined)
(Undefined)
↓
(Undefined) (Undefined)
(Undefined)