background image

13

PARTS LIST

EFFECTIVE

 IMPORTANT: WHEN ORDERING, SPECIFY VOLTAGE OR TYPE GAS DESIRED

             PAGE

          INCLUDE MODEL AND SERIAL NUMBER

 

OF

Some items are included for illustrative purposes only and in certain instances may not be available.

 

  

Number

Per

Unit

Description

  

   

Star Manufacturing International, Inc.

  

  Part

   Number

  Key

  Number

MODEL

    

 10/18/02

1

2

8G-624TZ-LP STAR-MAX GAS GRIDDLE
24" THERMOSTATIC CONTROL

1

2R-Z1273

2

KNOB-CONTROL

2

G3-Z6338

1

FRONT  PANEL

3

2A-Z0314

4

LEG

4

G3-GD0078 (624TZ)

1

GRIDDLE PLATE ASSEMBLY

5

G3-Y7046

1

GREASE  DRAWER GRIDDLE

6

G3-Y7047

2

SLIDE  DRAWER

7

G3-624008

2

BURNER ASSEMBLY

8

G3-624233 (624TZ)

1

MANIFOLD ASSEMBLY COMPLETE

G3-GD0037 (624TZ)

1

MANIFOLD ASSEMBLY COMPLETE

9

2P-1453

1

PLUG-PIPE

1 0

2V-6671

2

VALVE-PILOT

1 1

G3-T1022

2

TUBE ORIFICE

1 2

2J-Y7250

2

ORIFICE #55 L.P.

1 3

2A-9369

2

ORIFICE-FITTING

1 4

2K-Y7111

2

FITTING COMPRESSION

1 5

2T-Z4293

2

THERMOSTAT

1 6

2K-Y7123

1

INLET PIPE

1 7

G3-Y7252

1

INLET PIPE SUPPORT

1 8

G3-Y7355

2

TUBE-PILOT

1 9

G3-Y7356

2

PILOT BRACKET

2 0

G3-Z3785

1

REGULATOR-PRESSURE

2 1

G3-Y7040 (624TZ)

1/2

TENSIONER

2 2

G3-Y7039 (624TZ)

1/2

BULB-CLAMP

G3-Z4398 (624TZ)

1/2

BULB-CLAMP

G3-GD0036 (624TZ)

2

TUBE-WASHER ASSY. (NOT SHOWN)

Содержание STAR-MAX 8G-624MZ-LP

Страница 1: ...0 Sunnen Drive St Louis MO 63143 Phone 314 781 2777 Fax 314 781 3636 Installation and Operating Instructions STAR MAX PROPANE GAS GRIDDLE MODELS 8G 624MZ LP 8G 636MZ LP 8G 648MZ LP 8G 624TZ LP 8G 636T...

Страница 2: ...0 lbs 158 8 kg Dimensions 48 W x 27 3 4 D x 13 1 2 H 121 9 cm W x 70 5 cm D x 34 3 cm H 8G 624TZ LP Type Thermostat Control 2 Controls 40 000 BTU 498 sq in 3213 4 sq cm Grid Area 3 4 1 9 cm Plate Thic...

Страница 3: ...ions and product design without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously pur chased equipment MAINTENANCE AND REPAI...

Страница 4: ...system at test pressures in excess of 1 2 PSIG 3 45KPA This appliance and its pressure regulator must be isolated from the gas supply piping system by closing its individual manual shutoff valve durin...

Страница 5: ...or and thermostat will occur GAS PIPING Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet the full gas inputoftheappliance Iftheapplianceistobeconnecte...

Страница 6: ...wait 5 minutes to clear gas 2 Turn off all knobs and pilot valves and wait 5 minutes to clear gas 3 Turn on main valve and light all pilots 4 Turn burner knobs to desired setting 5 To turn burners off...

Страница 7: ...mitted to accumulate it will form a gummy cake and then carbonize into a hard substance which is extremely difficult to remove To prevent this condition the following suggestions for cleanliness shoul...

Страница 8: ...12...

Страница 9: ...IDDLE PLATE ASSEMBLY 5 G3 Y7046 1 GREASE DRAWER GRIDDLE 6 G3 Y7047 2 SLIDE DRAWER 7 G3 624008 2 BURNER ASSEMBLY 8 G3 624233 624TZ 1 MANIFOLD ASSEMBLY COMPLETE G3 GD0037 624TZ 1 MANIFOLD ASSEMBLY COMPL...

Страница 10: ...DLE 6 G3 Y7047 2 SLIDE DRAWER 7 G3 624008 636 648 3 4 BURNER ASSEMBLY 8 G3 636228 636TZ 1 MANIFOLD ASSEMBLY COMPLETE G3 648218 648TZ 1 MANIFOLD ASSEMBLY COMPLETE G3 GD0039 636TZ 1 MANIFOLD ASSEMBLY CO...

Отзывы: