Star GRILL EXPRESS GX10IG Скачать руководство пользователя страница 4

4

CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE 

DATA PLATE OF THE UNIT.

INITIAL START UP 

Level unit using the adjustable feet under the unit (approximately 1/2" adjustment).
Before using the unit for the first time, wipe down the exterior and grilling area with a damp cloth.  Take 

to a well ventilated area and heat for approximately 30 minutes.  The grill may emit a small amount of 

smoke as the cooking surfaces reaches 450°F.  Do not be alarmed, as the smoke is caused by oils 

associated with the manufacturing process and will stop when the burn off is complete.  Brush off any 

debris from the grilling surface.

SEASONING THE COOKING SURFACES

The cooking surfaces must be "seasoned" in order to reduce product sticking.  To season, bring grill 

to 300°F, until completed.  Brush upper and lower cooking surfaces with a 

salt free

 liquid vegetable 

oil.  If using an aerosol agent, first apply into a cup and then brush onto cooking surface.  Let sit for 20 

minutes, and then wipe clean using a warm damp cloth.  Repeat if required.

SETTING THE TEMPERATURE

The thermostat control knob is used to set the temperature to your requirements.  The maximum set 

point is 450°F (232°C), the minimum set point  

is 175°F (79°C).  See Knob Settings.

DAILY OPERATION

Check the power cord to insure that it is plugged into a proper outlet.
Check that the thermostat control is turned on.   

The pilot light will come on when the thermostat control goes past the 175°F.
Set the thermostat control knob to desired temperature.
Always allow 20 minutes of preheat time before loading the unit with product.   

Failure to allow sufficient preheat time will result in unsatisfactory cooking of the first load.

WARNING

ELECTRICAL SPECIFICATIONS

Model

Voltage

Rated Wattage

Amps

Plug

GX10IG

120V

1,400

11.7

NEMA 5-15P

230V

1,650

7.2

BS 1363A (16amp)

208/240V

1,350 / 1,800

6.5 / 7.5

NEMA 6-15P

GX10IS

120V

1,400

11.7

NEMA 5-15P

230V

1,650

7.2

BS 1363A (16amp)

208/240V

1,350 / 1,800

6.5 / 7.5

NEMA 6-15P

GX10ISG

120V

1,400

11.7

NEMA 5-15P

230V

1,650

7.2

BS 1363A (16amp)

208/240V

1,350 / 1,800

6.5 / 7.5

NEMA 6-15P

GX14IG

120V

1,800

15

NEMA 5-15P

230V

2,570

11.2

BS 1363A (16 amp)

208/240V

2,100 / 2,800

10.1 / 11.7

NEMA 6-15P

GX14IS

120V

1,800

15

NEMA 5-15P

230V

2,570

11.2

BS 1363A (16 amp)

208/240V

2,100 / 2,800

10.1 / 11.7

NEMA 6-15P

GX14ISG

120V

1,800

15

NEMA 5-15P

230V

2,570

11.2

BS 1363A (16 amp)

208/240V

2,100 / 2,800

10.1 / 11.7

NEMA 6-15P

GX20IG

208/240V

2,700 / 3,600

13 / 15

NEMA 6-20P

230V

3,300

14.4

BS 1363A (16 amp)

GX20IGS

208/240V

2,700 / 3,600

13 / 15

NEMA 6-20P

230V

3,300

14.4

BS 1363A (16 amp)

GX20IS

208/240V

2,700 / 3,600

13 / 15

NEMA 6-20P

230V

3,300

14.4

BS 1363A (16 amp)

Содержание GRILL EXPRESS GX10IG

Страница 1: ...TWO SIDED GRILLS MODEL GX10IG IS ISG GX14IG IS ISG GX20IG IS IGS Installation and Operation Instructions 2M Z7971 Rev L 12 2018 GX10IG...

Страница 2: ...r errors or omissions in information provided or conclusions provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for ser...

Страница 3: ...th carrier within 15 days Be certain to retain all contents plus external and internal packaging materials for inspection The carrier will make an inspection and will supply necessary claim forms VENT...

Страница 4: ...See Knob Settings DAILY OPERATION Check the power cord to insure that it is plugged into a proper outlet Check that the thermostat control is turned on The pilot light will come on when the thermosta...

Страница 5: ...fore the spring tension can be adjusted by tightening and loosening the Retainer bolts on the back of the unit CLEANING While holding top lid with one hand apply only cleaners which are safe for alumi...

Страница 6: ...ean the cooking surfaces when the unit is hot The surfaces are cast aluminum or cast iron and may crack or deform under the shock of rapid temperature change OPERATION TROUBLESHOOTING 1 Unit not heati...

Страница 7: ...orized service agency Star will not be responsible for charges incurred or service performed by non authorized repair agencies In all cases the nearest Star authorized service agency must be used Star...

Страница 8: ...6 15P ON 240V 1 800 WATT UNITS 20 AMP PLUG NEMA 6 20P ON 240V 3 600 WATT UNITS IEC 320 POWER INLET 16 AMP RATING SEE SEPERATE SKETCH 230V UNITS TOP ELEMENT 1 BLACK 3 3 2 1 TERMINAL BLOCK BOTTOM ELEME...

Страница 9: ...TOM PLATE REMOVED ITEMS ARE IN GENERAL LOCATION BUT MAY BE RELOCATED OR SCALED FOR CLARITY G 20 N 19 18 L TOP ELEMENT 3 2 3 1 1 11 12 11 12 CERTAIN INSTANCES MAY NOT BE AVAILABLE ILLUSTRATIVE PURPOSES...

Страница 10: ...OME ITEMS ARE INCLUDED FOR contents is permitted MODEL GX10 GX14 GX20 SERIES GX20 SHOWN STAR MANUFACTURING INTERNATIONAL INC SK2121 Rev J 11 12 2014 26 55 59 16 49 54 55 24 1 53 28 42 36 35 35 30 37 N...

Страница 11: ...2J Y6689 1 PILOT LIGHT 120V 120 V 2J Z2329 1 PILOT LIGHT 240 V 230 240 V 33 2V Z8859 2 SPACER SIDE ALL 34 D9 Z7697 1 PLATE BOTTOM 10 ALL 35 2A Z1485 4 FOOT 1 ADJUSTABLE ALL 36 2K Y3240 1 BUSHING HEYCO...

Страница 12: ...MINAL BLOCK 304 ALL 32 2J Y6689 1 PILOT LIGHT 120V 120V 120VC CANADA 32 2J Z2329 1 PILOT LIGHT 240 V 230 240 V 33 2V Z8859 2 SPACER SIDE ALL 34 D9 Z7842 1 PLATE BOTTOM 14 ALL 35 2A Z1485 4 FOOT 1 ADJU...

Страница 13: ...ALL 31 2E Z2894 2 TERMINAL BLOCK 304 ALL 32 2J Z3157 2 PILOT LIGHT 250V AMBER ALL 33 2V Z8859 2 SPACER SIDE ALL 34 D9 Z7918 1 PLATE BOTTOM 20 ALL 35 2A Z1485 4 FOOT 1 ADJUSTABLE ALL manufactured on o...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...16 STAR MANUFACTURING INTERNATIONAL INC Star Holman Lang Wells Toastmaster 265 HOBSON ST SMITHVILLE TN 37166 800 264 7827 www star mfg com...

Отзывы: