D-F0399 NP-266S/366S Specifications Ver.0.01 Provisional
11
3.3 Connector signal details
1) Power input connecter (Type II )
Printer side connector
: TCS7960-532010 (Hosiden)
Mating connector : TCP8927-53-1100, TCP8927-63-1100, TCP8935-53-1100
(Hosiden)
Equivalent
Pin No.
Signal name
Input/Output
Function
1
VH
Input
Power DC +24V
2 GND
- Power
ground
3 N.C
-
Shell FG
- FG
※
A sufficient volume of power supply is required to maintain print quality due to high peak current
that may run according to printing.
※
If power supply cable is excessively long, the operation may become unstable. Cable should be
as short as possible. If not available, connect cables near the printer and place an electrolysis
condenser of 2200µ between power supply and ground. Voltage resistance should be higher than
35V. Make sure to connect FG wire to prevent from ESD problems.
2) Serial Data signal input connector (Type II / Serial)
Printer side : 17LE23090-027(D4CK) (DDK) or equivalent
Host side : 17JE13090-02(DDK) or equivalent
Pin No.
Signal
Input/Output
Function
Remark
1 N.C -
2
TXD
Output
Serial transmit data
3
RXD
Input
Serial receving data
4 N.C -
5 GND
- Singnal
ground
6 N.C -
7
CTS
Input
Transmit permission signal
8
RTS
Output
Transmit request signal
9 N.C
3) Data Signal Input Connector (Type II / USB)
Printer side connector: B jack DUSB-BRA42-T11(DDK) or equivalent
Host side Connector: B plug
Pin No.
Signal
Input / Output Function
Remark
1
VBUS
Input
Power line
Non twist power line
2
D-
Input and output
Data line
Twist pair signal line
3
D+
Input and output
Data line
Twist pait signal line
4
GND
-
Power line
Non twist power line
Shell Shield
-
* Use USB cable which conforms to the standard (FULL SPEED)
* We do not support the operation by using a cable out of the standard. 3) Data signal input