background image

GENERAL INSTALLATION DATA 

 

This equipment is designed and sold for commercial use only by personnel trained and experienced 
in its operation and is not sold for consumer use in and around the home nor for use directly by the 
general public in food service locations.

Before using your new equipment, read and understand all the instructions & labels associated with 
the unit prior to putting it into operation.  Make sure all people associated with its use understand the 
units operation & safety before they use the unit.

All shipping containers should be checked for freight damage both visible and concealed.  This 
unit has been tested and carefully packaged to insure delivery of your unit in perfect condition.  If 
equipment is received in damaged condition, either apparent or concealed, a claim must be made 
with the delivering carrier.

Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a 
request for inspection of concealed damage must be made with carrier within 15 days.  Be certain to 
retain all contents plus external and internal packaging materials for inspection.  The carrier will make 
an inspection and will supply necessary claim forms.

WARNING: Improper installation, adjustment, alteration, service or maintenance 
can cause property damage, injury or death.  Read the installation, operating and 
maintenance instructions thoroughly before installing or servicing the equipment.

This fryer is equipped for the voltage and wattage indicated on the nameplate mounted on the lower 
right corner of the element housing.  It is designed for use on alternating current (AC) only.  It is 
intended for use by properly trained personnel only.

DO NOT CONNECT TO DIRECT CURRENT (DC)

The installation of the appliance should conform to the:

NATIONAL  ELECTRIC  CODE  AND  ALL  LOCAL  ELECTRIC  CODES  AND 
ORDINANCES  AND  THE  LOCAL  ELECTRIC  COMPANY  RULES  AND 
REGULATIONS

For your protection we recommend that a qualified electrician install this appliance.  He should be 

familiar with electrical installations and all electrical codes.  Proper connections and power supply 

are essential for efficient performance.  The external wiring should be in conduit or an approved type 

of flexible cable suitable for operation at 90° C (194° F) and of a proper size to carry the load.  The 

supply circuit should be properly fused and equipped with a means of disconnection, as required 

by local electrical code.  THE BODY OF THE APPLIANCE SHOULD BE GROUNDED - 

DO NOT 

GROUND TO A GAS SUPPLY LINE.

  Four legs are provided and should be installed for ease of 

cleaning.  Level unit by adjusting the (4) feet which have an adjustment of 1-3/8" (34.92 mm) for 

accurate leveling and perfect line-up with other units.

POWER SUPPLY

Models 530TF and 530TEF are wired at the factory for operation on a single phase power supply.  

For specific wiring, check the wiring diagram.

WARNING

CAUTION

SPECIFICATIONS

Model

Voltage

kW

Amps

Dimensions

Weight

Width

Depth

Height

Installed

Shipping

530TF

208V

8,638

41.5

24”

24”

16.75” 69 lbs (31.3 

kg

81 lbs (36.7 

kg)

240V

11,500

47.5

530TEF

208V

6,910

33.2

240V

9,200

38.3

Содержание 530TEF Series

Страница 1: ... DEEP FAT FRYER MODEL 530TF 530TEF SERIES Installation and Operation Instructions 2M Z16001 Rev 5 31 2012 530TF ...

Страница 2: ...ate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with such use MAINTENANCE AND REPAIRS Contact your local authorized service agent for service or required maintenance Please record the model number serial number voltage and purchase dat...

Страница 3: ...quipped for the voltage and wattage indicated on the nameplate mounted on the lower right corner of the element housing It is designed for use on alternating current AC only It is intended for use by properly trained personnel only DO NOT CONNECT TO DIRECT CURRENT DC The installation of the appliance should conform to the NATIONAL ELECTRIC CODE AND ALL LOCAL ELECTRIC CODES AND ORDINANCES AND THE L...

Страница 4: ...st be pressed to restore operation Should the hi limit control activate twice in succession the primary thermostat should be checked for malfunction by a qualified service technician Each pot is equipped with its own HI LIMIT THERMOSTAT FRYING After fat has been added turn the switch on and set the thermostat at 200 F 92 4 C After the fat has melted turn the thermostat to the desired setting Inclu...

Страница 5: ...es away from hot oil and its vapors Never allow water or ice to get in hot oil IT CAN EXPLODE WARNING ENVIRONMENT Keep your floors clean and free of grease and all other substances so no one slips accidentally and contacts the hot fryer Keep areas and filters clean above your fryers Oil soiled lint or dust can ignite easily and flames will spread rapidly WARNING MAINTENANCE Have your equipment che...

Страница 6: ...too long at too low temperatures One answer to both problems is exact control of heat so that fat neither smokes up nor soaks up Of course no fat keeps forever Not only heat but air and moisture salt particles and crumbs of food work to break it down But you can slow up fat deterioration by maintaining proper temperatures and by draining your kettle filtering or straining the fat once or twice a d...

Страница 7: ...ps Breading 350 4 Shrimp Batter Some prefer soaking 1 2 hour in cold seasoned milk 350 3 Smelts Breading Cut spinal cord several 350 4 places to prevent curling MEATS Chicken Fried Steak Breading Sever all connecting membranes at one inch intervals to prevent curling 360 3 4 Cutlets Breading 350 3 4 Chops Breading 340 3 4 Meat Balls Breading or rolled in flour 340 4 6 Brains Breading 340 3 5 VEGET...

Страница 8: ...ve cleaners abrasive pads product identifiers and point of sale attachments or any other non food object tha comes in continuous contact with the roller coating This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalog items only Star s warranty on Special Products is six 6 months on parts and ninety 90 days o...

Страница 9: ... C D E F RIGHT HAND CONTROL HOUSING ASSEMBLY 530015 LEFT HAND CONTROL HOUSING ASSEMBLY 530016 MODEL 530TE MODEL 530T TMFE30 208V 1 PH 240V 1 PH 208V 1 PH 240V 1 PH 6910 33 2 8 9200 38 3 8 8638 41 5 8 11500 47 9 6 WATTS AMPS SUPPLY MIN AWG FOR SUPPLY CONNECTION USE COPPER WIRE RATED AT LEAST 90 C 10 G G POWER SUPPLY BLOCK 2M Y5135d ...

Страница 10: ...30TF 530TEF CERTAIN INSTANCES MAY NOT BE AVAILABLE SK2590 Rev 5 31 12 ILLUSTRATIVE PURPOSES ONLY AND IN SOME ITEMS ARE INCLUDED FOR 8 9 10 1 2 4 41 40 7 14 24 25 17 18 21 22 27 29 3 20 5 15 23 28 32 31 30 33 38 34 37 19 12 11 13 16 6 36 35 39 26 ...

Страница 11: ... Y5169 ELEMENT 240V 4600W 530TEF 17 E1 Y1889 2 BRACE ELEMENT LONG 18 E1 Y1890 2 BRACE ELEMENT SHORT 19 E1 7363 2 CLAMP THERMOSTAT BULB 20 2I 5659 4 GROMMET CAPILLARY TUBE 21 E1 Z15706 2 KNOB THERMOSTAT 22 E1 116314 2 SIGNAL LIGHT POWER ON WHITE 23 E1 116313 2 SIGNAL LIGHT HEATING AMBER 24 2A 5401 2 PIN COTTER 3 4 25 E1 Y5108 2 ROD CATCH RELEASE 26 2T Z7208 2 THERMOSTAT 27 2T Y1668 2 SAFETY THERMOS...

Страница 12: ...12 STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com ...

Отзывы: